Clay,
The JMRI help system includes summaries of the signal systems. For Basic:
The generated SML results in ABS signaling. APB signaling can be implemented by adding Logix controlled direction (internal) sensors to the SML.
Dave Sand
toggle quoted message
Show quoted text
On Dec 3, 2018, at 4:24 PM, Clay <claysmith44@...> wrote:
I model the L&N circa 1974, however when I look at all of the signal definitions there isn't one that I recognize for the L&N so I picked Basic Model Signals.
From them I'm not sure to choose in the next two windows. In mask type I think the chooses were single search light low signal, single search light high signal, double search light low signal, and double search light high signal. I don't know the differences here. I'm fairly adapt at SSL, however I think SML is more like what I want based on I like to operate without a dispatcher.
Using SML, does the logic recognize the direction of travel?
I tried reading the help files, but I could not find anything that addresses the above question. If there is something that I missed, please point me in the right direction.
Thanks.
Clay Smith
Hopkinsville KY