Address Range
If your Power Cab firmware (second screen at startup of your Power Cab, after the "Pro Cab V1.3" message) is:
- "V1.28C" the only valid addresses for extra cabs are 3 & (unofficially) 4.
- "V1.65" the only valid addresses for extra throttles ?are 3, 4 and 5. Non-throttle devices such as the NCE USB, Mini Panel or AIU can also use addresses 8, 9 & 10. However if you have ever done a System Reset, you will have lost all the extra addresses and be back to the V1.28C restrictions.
- "V1.65B" the only valid addresses for extra throttles ?are 3, 4 and 5. Non-throttle devices such as the NCE USB, Mini Panel or AIU can also use addresses 8, 9 & 10.

Similar ?comments apply to the SB3/5 with the range 2-5 for V1.28 and 2-7 for V1.65B.

Configuration Instructions

Here are the best settings for JMRI and jumpers for Power Cab (and also SB5).

Make sure you always unplug/replug both cables on the NCE USB after changing jumpers.?

It also explains how to read the version of your NCE USB (only the first digit counts, the last three report how your jumpers 2-4 are set and jumper 1 is ignored on all systems).


Power Cab Instructions

The correct settings for a Power Cab V1.65 or V1.28 (as shown when the Power Cab starts up) and an NCE USB V6 (or you are not sure of the USB version) ?are:
- All USB Jumpers off (or at least 2, 3 & 4. Jumper 1 is ignored).
- JMRI preferences are:
-- System manufacturer: NCE
-- System connection: ?NCE USB
-- Serial port: <whatever is appropriate for your system>
-- USB version: V6.x.x
-- System: PowerCab
-- Additional Connection Settings checkbox ON
--- Baud rate: 9600.

The JMRI console log should then report V6.3.0. If it reports V7.3.0 and your Power Cab is V1.65, use the settings below instead.
If you don't get a version number or the system does not work, Use Help->System Console...->Copy to clipboard and paste into a post for us to see.

The correct settings for a Power Cab V1.65 or V1.65b and an NCE USB V7 ?are:
- All USB Jumpers on (or at least 2, 3 & 4. Jumper 1 is ignored).
- JMRI preferences are:
-- System manufacturer: NCE
-- System connection: ?NCE USB
-- Serial port: <whatever is appropriate for your system>
-- USB version: V7.x.x
-- System: PowerCab
-- Additional Connection Settings checkbox ON
--- Baud rate: 19200.

The JMRI console log should then report V7.3.7.

SB5 Instructions

The correct settings for an SB5 and an NCE USB V7 ?are:
- USB Jumper 4 on. All others off (or at least 2 & 3. Jumper 1 is ignored).
- JMRI preferences are:
-- System manufacturer: NCE
-- System connection: ?NCE USB
-- Serial port: <whatever is appropriate for your system>
-- USB version: V7.x.x
-- System: SB5
-- Additional Connection Settings checkbox ON
--- Baud rate: 19200.

The JMRI console log should then report V7.3.1.

General Troubleshooting

If the system does not work after this:
- If your SB5/Power Cab is V1.65 rather than V1.65B, you may have been affected by a firmware issue (triggered by a System Reset).
- Your NCE USB may be set to a bad cab address (V7 only).
?In either case, go through the following :
- Quit JMRI.
- Ensure neither LED on the NCE USB is stuck ON. If so, power cycle the USB by unplugging it from the cab bus cable.
- Ensure you have no other throttles connected.
- Restart JMRI and immediately go to Configure USB Interface under the NCE menu.
- Set the Cab ID to 3.
- Attempt a JMRI operation (use a throttle, Identify a decoder).
- The status line should stay green and it should work?
-If this does not work, do not fiddle with any other settings but instead:
-- Observe whether the Cab Bus LED on the NCE USB is stuck on and report back.
-- Use Help->System Console...->Copy to clipboard and paste into a post for us to see.

--?
Dave in Australia


On 9 Nov 2018, at 7:15 AM, Derekr <m1arfm0dfx@...> wrote:

Dave do all these settings for the PowerCab and AIU,s hold good for an SB5 i.e. USB jumpers and cab IDs.