¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: Jumbo sized lytic stack for HV supplies ! Oil cap warning. DIODES
Mike, I bought a bunch of these SHV connectors and bulkheads from Powell, a Kings stockist/distributor. rmilligan@... , Ryan Milligan from Powell was kind enough to send a handul of these
By PA3DUV <pa3duv@...> · #168 ·
Re: HIGH SWR / HIGH REFLECTED POWER SHUT DOWN CIRCUIT !!
I just put an M24 2 metric tonne lifting eye on a 1ft studbolt through the steel reinforced concrete ceiling of my garage to get the 30 kVA 1500 rpm diesel genset and HT power supply on and off the
By PA3DUV <pa3duv@...> · #166 ·
Fw: Jumbo sized lytic stack for HV supplies ! Oil cap warning. DIODES
Let me correct this: Jim said: This is my "external cap box". I used Millen Red/ Black HV connector's on it. IF using the Millen's.... either use nylon mounting screws or mount em on Micarta. Both
By Mike Sawyer <w3slk@...> · #167 ·
Re: Jumbo sized lytic stack for HV supplies ! Oil cap warning. DIODES
Jim said: This is my "external cap box". I used Millen Red/ Black HV connector's on it. IF using the Millen's.... either use nylon mounting screws or mount em on Micarta. Both Kings and ROWE make
By Mike Sawyer <w3slk@...> · #165 ·
Re: More QRO secrets revealed.... 15 -20 kw baluns !! - Pictures, PLEASE
Am 23.09.2006 um 15:41 schrieb pentalab: I'm dying to see some beautiful pictures of all those neat things you describe... Please be so kind and put some into the photos area of this group on
By Frank Goenninger <frgo@...> · #164 ·
Re: More QRO secrets revealed.... 15 -20 kw baluns !!
thing. The typ W2DU baluns using 303 teflon coax.. and the tiny type 75 beads would heat up with just a 500 w dead cxr on all bands from 1.8 to 30 mhz. They switched to type 43 small beads... and the
By Paul Christensen · #163 ·
More QRO secrets revealed.... 15 -20 kw baluns !!
I couldn't resist. To make a 40-10m choke balun for 40-10m yagi's use type 43 beads [1" OD x .5" ID x 1" long] slid over RG-393 teflon coax. The balun is 17" long when
By pentalab <jim.thomson@...> · #162 ·
Re: HIGH SWR / HIGH REFLECTED POWER SHUT DOWN CIRCUIT !!
it's just as easy to build a big one as a small one. ##### Use a cum-a-long hooked to a basement beam... or one of those small devices used to lift small engines. Me... after tearing
By pentalab <jim.thomson@...> · #161 ·
Jumbo sized lytic stack for HV supplies ! Oil cap warning. DIODES
If any of you intend to series parallel Oil caps for greater V ratings... BEWARE. I did just that with 4 x 50 uf @ 4500 V units. These were each 12" tall x 8' wide x 4" thick.
By pentalab <jim.thomson@...> · #160 ·
Re: HIGH SWR / HIGH REFLECTED POWER SHUT DOWN CIRCUIT !!
By R L Measures · #159 ·
Transformer info on Wikipedia
All, I started editing the page on transformers at Wikipedia at 6:00 PM this evening, and it is now 4:30 AM in the morning. I corrected a few errors from others plus added a complete section on steel
By craxd <craxd1@...> · #158 ·
Re: HIGH SWR / HIGH REFLECTED POWER SHUT DOWN CIRCUIT !!
the like. Some pics of your "QRP" amps (They also make the usual 10 kw 5 kw.. 2.5 kw qrp slugs.) would be very much appreciated. ### Tnx Dick..... As soon as I can figure out this pix
By pentalab <jim.thomson@...> · #157 ·
Re: HIGH SWR / HIGH REFLECTED POWER SHUT DOWN CIRCUIT !!
Great info Jim! NOW we're talking amplifiers ;-) Thuis yahoo group has the possibility of posting pictures, files and the like. Some pics of your "QRP" amps (They also make the usual 10 kw 5 kw..
By PA3DUV <pa3duv@...> · #156 ·
HIGH SWR / HIGH REFLECTED POWER SHUT DOWN CIRCUIT !!
wrote: full ### Peter, et all ### I had an engineer buddy of mine cook up a high reflected power shut down circuit for me. My buddy got a hold of a ton of Bird single line
By pentalab <jim.thomson@...> · #155 ·
Coaxial Dynamics now makes a 25 kw slug for a 7/8" line section !!
Gents This may well be old news to some... but Coaxial Dynamics makes a 25 kw slug.[2-30 mhz].. for a standard 7/8" line section....cheap. They also make the usual 10 kw 5 kw.. 2.5 kw
By pentalab <jim.thomson@...> · #154 ·
Re: "New" method of fabricating a better chimney
wrote: use a full ### Partially agreed. ..BUT the 3CX-6000A7 is rated at 3.5 A of plate current CCS. [7 kv under load] . ## as is.... with 2.5 A of plate current @ aprx 6900 V
By pentalab <jim.thomson@...> · #153 ·
Re: Can Grid Dissipation in metal GG triodes be increased ????
That's pretty much what Care and Feeding ... ... says. Avg. DC grid- current is measured with an ordinary panel meter.
By R L Measures · #152 ·
Re: Can Grid Dissipation in metal GG triodes be increased ????
wrote: with ### whoa. Are you saying RF cathode V x DC grid current = grid diss ???? ### That equates to way below 200 w of grid diss.... based on 45 ohm input Z... and 800w
By pentalab <jim.thomson@...> · #151 ·
Re: YC-156 amp
wrote: ### 9-12 kw out with 200w of drive. ..easy. [7900 v no load] #### The trbl with 4-1000's is trying to find good one's these days. I had single 4-1000's and pairs of em...
By pentalab <jim.thomson@...> · #150 ·
Re: YC-156 amp
That was my reason for moving to 4CX3000A and bought 6 for $100. Jan Erik Holm <sm2ekm@...> wrote: Well they are difficult to get stable. They run just fine now but Ive used 4-1000s
By FRANCIS CARCIA <carcia@...> · #147 ·