Eimac states driving impedance is 115 ¦¸
grid dissipation = peak voltage X grid current.?so at 100W drive, peak grid voltage is 150V
150V X 0.2Ig = 30W grid dissipation. ?30W
?
I don't think you can calculate the power dissipated on the grid this way : grid dissipation = peak voltage X grid current.
What are your sources on this interesting topic?
I don't know where the 100W of the input are dissipated.
If your formula is good, it would be very worrying.
--
F1AMM
Fran?ois