Is the band switch in good condition, in the correct position?
On Sunday, December 10, 2023 at 09:41:10 AM EST, Nick Jones KC0YKO <kc0yko@...> wrote:
All,
Question for the group. I am working on an Ameritron AL-80 (not A or B). When tuning it up I run out of load. I max the load cap out at zero on all bands. (fully meshed/max capacitance). It behaves the same on a two different dummy loads so I believe it to be an issue with the amp. Before I add another doorknob across the load cap, I figured I would ask the group for other ideas. -- 73 Nick KC0YKO