On Wed, Feb 26, 2025 at 01:35 PM, M Verpelli wrote:
Here I am again to ask one last thing (I hope).
From what I understand, when you want to move a program to minidisk
MNT19E 19E Y/S to make it available to all other users, you have to (re)save the CMS system.
So:
1) acc 19E z, to make it available for writing
2) copyfile my program a = = z
3) read the MAINT MEMO B and
3.1) vmsetup cms
3.2) cp define stor 16m
3.3) ipl 190 clear
?
?
You didn't press enter at this point did you??
On checking it needs to be straight after the IPL
3.4) savesys cms
4) shutdown and reipl
5) with any user after logon I get:
DMSFRE161T INVALID DMSFRET CALL FROM F87AE8, ERROR NUMBER 5.
DMSFRE164T LOW-CORE NUCLEUS STORAGE POINTERS DESTROYED (INTERNAL ERROR CODE 5) RE-IPL CMS.? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ??
DMSFRE165T CHAIN HEADER AT 0036F0: 0001EC20 0000000B 000011B8 10F00200.
CP ENTERED; DISABLED WAIT PSW '00020000 00F812B6'
?
quite nasty and unfriendly...
?
I also tried the same things with a copy of VM/370 CE v1r1.2 just downloaded and therefore not "screwed" by me previously.
The result was the same.
?
Any advice is welcome, thanks!
?
Marco