Hi Bob:
That did not work either. ?The spooled file is there at level 2 as long as the printer is drained. ?Starting it and the output vanishes.
So I tried something else. ?I attached 00F to the 2nd level VM and now printing works flawlessly with no extra steps or closes.
toggle quoted message
Show quoted text
On Thu, 2024-10-24 at 05:47 -0700, Bob Polmanter wrote:
Daniel,
?
You have to issue the CP CLOSE PRT from the virtual machine console (first level) userid that is hosting the 2nd level VM system.
?
At that point, if your first level system printers are stopped (e.g., device 00e or 00f) then you should see the output in a CP Q PRT ALL command, sitting in the first level spool.? If the printers are started then you will see a message on the first level operator console that the output is bring printed and it should be available in your disk file.
?
Regards,
Bob
?