Re: Upgrading slider
Adjusting the cast iron table flatness and the alignment of the sliding table to a flat cast iron table is part of the normal commissioning procedure. A Felder tech will align the sliding table to be
By
David P. Best
·
#136193
·
|
Re: Upgrading slider
Well Netanel, did you look closer? What did you find? Post photos as requested please.
David
By
David P. Best
·
#136192
·
|
Re: Upgrading slider
I level the machine today and start measure the tolerance of the saw.
I find out that the cast iron top is out of complainer of 0.25mm. It looks a bit high, no?
I thought Felder line suppose to be
By
netanel.belgazal@...
·
#136191
·
|
Re: GRIT Automation
So do you the power the grit e-stop from DC current?
By
netanel.belgazal@...
·
#136190
·
|
Re: GRIT Automation
Netanel,
I guess I was not clear in the video.? The transformers are in the machines already.? I am just using existing taps to power the e-stop controllers.? It does not connect to the
By
PK
·
#136189
·
|
Re: Dust Collector
#dustcollection
Imran,
Your point holds up if properly sized for the workspace volume and
particulate filtration, sure. Bigger cfms and smaller particulate is the
goal however it's
By
Brett Wissel
·
#136188
·
|
Re: Dust Collector
#dustcollection
It always amuses me that people who have no hesitation in spending 10's of thousands of dollars on a table saw and other workshop machinery always want a cheap answer to dust collection even though it
By
@ChrisParks
·
#136187
·
|
Re: Dust Collector
#dustcollection
If you are looking primarily for "removing the dust from the air", I would say it depends on which model has the most CFM capability in addition to the most static pressure.? This determines how well
By
Aaron Inami
·
#136186
·
|
Re: Dust Collector
#dustcollection
Brett,
Let¡¯s say there is no HVAC, what about running a good air cleaner vs sizing the dust collector beyond chip collection needs. Upsizing the dust collector seems like an expensive option to
By
imran
·
#136185
·
|
Re: Dust Collector
#dustcollection
David Davies -
My conclusions have led to:
1. Anything HEPA-labelled will outfilter fine particulate better than non
HEPA labelled. However it will have tradeoff of less capacity.
2. I believe total
By
Brett Wissel
·
#136184
·
|
Re: Dylos User Manual
It is interesting, Jim. Thanks for chiming in!
I thought there must be an assumption about material density baked into the Dylos machine. Maybe Dylos shares that assumption. It does not have to be
By
John Hinman
·
#136183
·
|
Dust Collector
#dustcollection
With all of the discussion about the Dylos sensor it has me wondering about which dust collector really does the best job at removing dust before it gets into the air.? It seems to me there are three
By
David Davies
·
#136182
·
|
Re: Dylos User Manual
The Dylos (and other real time meters) use a diode laser and detector to
measure particulate passing frequency and then estimate the size of the
particles from the efficiency of the scattering (ie:
By
Jim Dayton
·
#136181
·
|
Re: BF7-41 (1999) Slider Adjustment
David and Imran,
Thank you for your swift responses. It was much appreciated. That¡¯s was I suspected (and feared), but now have a good sense of the device needed to take those measurements. I just
By
Paul.H.Denison
·
#136180
·
|
Re: Dylos User Manual
Thanks for the information, fellows!
The ability of the DC1700-PM to report results that are comparable to published safety standards is very helpful. I had missed that when looking at Dylos
By
John Hinman
·
#136179
·
|
Re: Dylos User Manual
Agreed with Rod and Stephen ¨C the Dylos air quality monitor has been a big help. I have a DC1100-Pro, & use an Oneida DC and a Jet ceiling-mount air cleaner.? For my garage shop, this setup works
By
Rich M.
·
#136178
·
|
Re: Stripped Bolt Removal
Hi,
Not sure what to suggest if it is completely stripped, but I just want to
make sure you are trying to turn it clockwise (opposite from the usual
loosening turn). Sorry if this is obvious.
My
By
Cornelius
·
#136177
·
|
Re: Dylos User Manual
Dealing with gas turbine emissions on the regular, that doesn¡¯t surprise me
at all. It¡¯s actually quite awful how high ambient outdoor PM2.5/10 levels
are in some locations. It makes it really
By
Jim Dayton
·
#136176
·
|
CF741 with Grit Automation
After reading all the nice comments about the Grit Automation on the previous topic, I wish to take this route with my CF741. However, being a combination machine, I was wondering if anyone had
By
pierre.bourassa@...
·
#136175
·
|
Stripped Bolt Removal
Hi Guys,
The bolt on my K940 to replace my blade seems to be stripped. I¡¯ve tried using a different hex Allen wrench with no luck. How would you guys go about removing this?
Thanks
By
jppetricca@...
·
#136174
·
|