FW950 Classic table height display
Greetings all, Does anyone know if the "Thick-Box" display for table height can display in Inches instead? Thanks, Karel
By
kboonzaayer@...
·
#136204
·
|
Re: GRIT Automation
No, Off the 120 or 240 tap. PK
By
PK
·
#136203
·
|
Re: Upgrading slider
This link will give you some images of where to find that support strut and the bolt that can adjust the center of the cast iron top along the edge nest to the sliding table - from the archives:
By
David P. Best
·
#136202
·
|
Re: Upgrading slider
To add to David and Aaron¡¯s advice, keep in mind that, if needed, there should be a 5th support point to counter the weight of the saw aggregate. I am not 100% about K700 but it is present in my KF
By
imran
·
#136201
·
|
Re: Upgrading slider
Thank you David. Aaron - I don¡¯t have the mobility kit. I installed yesterday levelling feet on the machine.
By
netanel.belgazal@...
·
#136200
·
|
Re: Upgrading slider
Sorry, one more thing.? I see that you have a mobility kit.? If you decide to move the saw around a lot, you will likely cause the alignment to go out of spec whenever you "move" the saw.? If your
By
Aaron Inami
·
#136199
·
|
Re: Upgrading slider
Netanel, I had the same kind of precision level results on my K700S before I adjusted the leveling feet.? I would recommend doing leveling feet first.? This should let you resolve the cast iron
By
Aaron Inami
·
#136198
·
|
Re: Upgrading slider
In that case, you should make some adjustments. The important thing is that the cast-iron table is as flat flat as possible by getting the edge along the rip fence to be coplanar with the edge along
By
David P. Best
·
#136197
·
|
Re: CF741 with Grit Automation
You will need to put a current sensing coil on one lead of all of the motors (only three I think). That is an alternative (and possibly cheaper, and less feature rich approach. Still needs the current
By
Jonathan Martens
·
#136196
·
|
Re: Upgrading slider
I am not talking about the slider itself. And how it is reference to the cast iron. I am talking about the fact that the cast iron itself isn¡¯t coplanar
By
netanel.belgazal@...
·
#136195
·
|
Re: Upgrading slider
I use the precision machine level and align it on one side of the saw. I moved it to the backend of the cast iron and it show a big difference. I added a filler gauge of 0.25¡± (inch and not mm as
By
netanel.belgazal@...
·
#136194
·
|
Re: Upgrading slider
Adjusting the cast iron table flatness and the alignment of the sliding table to a flat cast iron table is part of the normal commissioning procedure. A Felder tech will align the sliding table to be
By
David P. Best
·
#136193
·
|
Re: Upgrading slider
Well Netanel, did you look closer? What did you find? Post photos as requested please. David Best DBestWorkshop@... https://www.flickr.com/photos/davidpbest/collections/
By
David P. Best
·
#136192
·
|
Re: Upgrading slider
I level the machine today and start measure the tolerance of the saw. I find out that the cast iron top is out of complainer of 0.25mm. It looks a bit high, no? I thought Felder line suppose to be
By
netanel.belgazal@...
·
#136191
·
|
Re: GRIT Automation
So do you the power the grit e-stop from DC current?
By
netanel.belgazal@...
·
#136190
·
|
Re: GRIT Automation
Netanel, I guess I was not clear in the video.? The transformers are in the machines already.? I am just using existing taps to power the e-stop controllers.? It does not connect to the e-stops. PK
By
PK
·
#136189
·
|
Re: Dust Collector
#dustcollection
Imran, Your point holds up if properly sized for the workspace volume and particulate filtration, sure. Bigger cfms and smaller particulate is the goal however it's achieved. [email protected]>
By
Brett Wissel
·
#136188
·
|
Re: Dust Collector
#dustcollection
It always amuses me that people who have no hesitation in spending 10's of thousands of dollars on a table saw and other workshop machinery always want a cheap answer to dust collection even though it
By
@ChrisParks
·
#136187
·
|
Re: Dust Collector
#dustcollection
If you are looking primarily for "removing the dust from the air", I would say it depends on which model has the most CFM capability in addition to the most static pressure.? This determines how well
By
Aaron Inami
·
#136186
·
|
Re: Dust Collector
#dustcollection
Brett, Let¡¯s say there is no HVAC, what about running a good air cleaner vs sizing the dust collector beyond chip collection needs. Upsizing the dust collector seems like an expensive option to
By
imran
·
#136185
·
|