Re: 3 phase high leg placement
¿ªÔÆÌåÓýHi Chris, ? I have an odd interest in Felder electrical schematics. The one you shared is very intriguing. I do not have exposure to older Felder schematics, so this one is new to me. More on this later, but I would follow Rod¡¯s direction to identify the 2 lines connected to the transformer. I checked Rod¡¯s suggestion against one schematic and it looks good. Basically, the way machine is wired only one pair will measure resistance, which is the resistance of the transformer input winding. A measurement on the 2 other pairings should be high resistance as you are measuring an open. If you measure resistance on more than 1 pair then I would not use this method. In that case, there are slightly more involved methods that could be utilized. BTW, I did not follow Rod¡¯s step 6, I think there is a word missing but I understand the concept, hopefully you do too. ? Now back to your schematic. Your machine uses a PCB mounted solution. I have seen pictures of a larger PCB in an older KF700 but this one is rather small. It is from Siemens and PN is C98 451-D6094-A1. It is obsolete but I found a German site that apparently offers repaired units. ? Read on if further details are of interest to you. There are 3 images on the site but one below is good for illustration. I have attached a marked up drawing of this board, identifying few components and transferring signal types to the connectors for ease in locating them. ? ? The 24 VAC transformer is on bottom left. Based upon other Felder schematics that I have looked at, here is what I believe are some key components. K1 and K4 (tall black blocks with white covers) are relays. Typically one is start relay that turns on momentarily and then drops off, the 2nd one is latched and drops off with red button or any interlock. 3 brick red coils (with a wire going thru the middle) are for current sensing, assuming for braking function. Two white blocks, identified on mark up as S1 & S2, are likely for adjusting brake force and duration. ? Imran Malik ? ? From: [email protected] On Behalf Of chris connolly
Sent: Saturday, July 01, 2023 11:12 AM To: [email protected] Subject: Re: [FOG] 3 phase high leg placement ? Thanks for that Rod. The Felder tech I spoke with yesterday told me that 99% of the time the manufactured leg will go to Line 2 on the machine (usually brown wire). I will try you method to verify. ?I have attached the wiring diagram from my F700 shaper, any chance you could explain how one might decipher where the manufactured ?leg should go based on the diagram? Thank you ? ? ? ? ? ? ? ? ? ? ?
? |