Voltmeter on the wires would be the true answer¡­.

Brian Lamb
blamb11@...
www.lambtoolworks.com




On Mar 8, 2023, at 9:37 AM, aero_qfi <davesawdon@...> wrote:

[Edited Message Follows]

On Wed, Mar 8, 2023 at 03:40 PM, Brian Lamb wrote:
The start/stop and limit switch circuits are low voltage
Hmm, I've just gone back to look at the diagram and it shows a "control transformer" as being an option. I agree that 24V controls are pretty standard nowadays but this looks more like an isolating traffo (220V -220V/63VA) than one for LV so maybe Felder switched to LV controls on later models. When I find the right tuit to make the changes I'll check the voltage and report back.?

Edited to add ... that I found the spec of the contactor shown on the parts listing: the coil voltage is 220V so I guess that's pretty conclusive

Dave (in the UK)

Join [email protected] to automatically receive all group messages.