I think sheetmetal gauge is based on this, the weight per square foot per inch of thickness. This is why different materials can be different gauge for the same thickness:
As the gauge number increases, the material thickness decreases. Sheet metal thickness gauges for steel are based on a weight of 41.82 pounds per square foot per inch of thickness. This is known as the Manufacturers¡¯ Standard Gauge for Sheet Steel. For galvanized material, the decimal by gauge and weight per pound is different than steel due to the coating weight.
Example 1: A 10 gauge steel sheet which has a thickness of 0.1345 inches will weigh 41.82 * 0.1345 = 5.625 pounds per square foot.
Example 2: A 10 gauge galvanized sheet which has a thickness of .1382 inches will weigh 41.37 * .1382 = 5.718 pounds per square foot.
I know in shotguns it¡¯s based on the diameter of how many balls you get out of a pound of lead. Wire gauge is a whole different situation entirely. Probably why in manufacturing they have gotten away from most gauge call outs and now specify thickness of the material.
toggle quoted message
Show quoted text
Just as a point of clarification, when discussing sheet metal or wire ¡°gauge¡±, the lower the number the larger (thickness, diameter, etc) the dimension. For example, for bare sheet metal 16ga is about .060¡±, 10ga is about .135¡±. The values change for brass, aluminum and other alloys and also for wire but the concept stays the same, lower number = larger dimension. For sheet metal the best I have been able to determine is that for a fixed volume, say 12¡±x12¡±x12¡±, the number of 12¡±x12¡± plies needed to stack up to 12¡± is smaller for thicker material and larger for thinner material. The methodology used to determine the seemingly random gauge thicknesses is still a mystery to me.
?Air Handling is a good supplier of spiral goods: .? They have the straight section joint pieces I mentioned.
is my favorite snap lock supplier.??
Marlowe
Marlowe
On Wed, Jul 14, 2021, 10:32 AM imranindiana via <imranindiana=
[email protected]> wrote:
Hi Bird,
¡°Maybe I¡¯ll try something lighter gauge as you suggest, Imran.¡±
If by that you mean HVAC fitting to connect then yes. If you mean spiral pipe than that is not what I suggested. I like the heavy gauge pipe I got from Rockler. Like others have suggested just screw or rivet. I also used AL tape to seal and yes, it is hard to remove.
Definitely pre drill. I even connected some cast AL blast gates to spiral pipe with screws.
Imran
On Jul 14, 2021, at 9:44 AM, Bird Cupps <
birdc@...> wrote:
Maybe I¡¯ll try something lighter gauge as you suggest, Imran.
--