Re: Nordfab rigid metal flex duct question #dustcollection


 

Agree with Brian G on his points about rolling offsets - I have employed them with my Nordfab kit and they are a bit shorter and a good bit more efficient in terms of loss versus sticking to strictly orthogonal?layouts.
Brian L, I love the garbage can separator, it must be the best dust collection bodge I have yet to see. It looks low- loss, suction will keep the lid on tight -- how does it do at separation effectiveness, e.g., what % does it collect? This looks very good for keeping fine dust from the far end where I'm thinking of adding the compression thingy to convert planar shavings into fuel pellets.
Cheers
Eric

On Wed, Jun 10, 2020 at 10:27 PM Brian Greene <Brian@...> wrote:
Google ¡°pipe offset¡± and ¡°rolling offset¡±, and there are calculators.? With 45s and 90s you can make any angle you need, just ¡°roll¡± it.?

That¡¯s a 45 degree fitting that runs at 15ish into the dc.? If you use 2 or more you can get shorter and fancier, but with dc longer runs between bends is better anyway.



Sent from a device with less than stellar autocorrect

On Jun 10, 2020, at 10:00 PM, Alex Bowlds <aabj@...> wrote:

?Nordfab has flexible pipe sections, not just rigid pipe. I think they are a bit more costly than a comparable length of the rigid Nordfab piping. Check their website to see if any of their flexible options will meet your needs.?

Alex


On Jun 10, 2020, at 2:56 PM, jmkserv@... wrote:

?
Joe, without seeing a potential layout it's extremely hard to offer advice but in my delusional mind and see a solution that only relies on ready made pieces using tees and large radius elbows. No flex or custom made elbows necessary.

On Wed, Jun 10, 2020 at 4:18 PM Joe Jensen <joe.jensen@...> wrote:

My shop has 9 foot sidewalls and vaulted ceilings. I am going to run the Nordfab duct up on the ceiling to maximize clearance overhead.? I have 3 options as I see it:
1) order custom elbows.? slickest solution but they need to be fabricated pretty accurately as the Nordfab does not seem to have any forgiveness once clamped.
2) do flex pipe for the custom angles.? The Nordfab rigid metal flex pipe looks perfect.? I need 7" and the min radius is quite large at 50" but that's not really an issue for me.? with this approach it would fit well for sure.
3) Do spiral wire poly hose.?

Thoughts, and has anyone dealt with custom angles?? Accuracy of Nordfab custom parts?



--
John Kee
JMK Services