Re: Transformer primary voltage entry won't stay put on Mac version


 

transformer current capability for high voltage section is 60 mA.
Load is 13.2 mA
I am not aware of anyone else working on this.

I'm glad I had to go through the specs again as I was in error in the original post on a couple of values. Secondary nominal voltage (one side) from manufacturer = 300 volts, not 330 as I had posted in the original post.

Transformer current capability for high voltage section is 60 mA.
Load is 13.2 mA
Primary voltage 120, primary measured winding dc resistance = 10 ohms
Secondary nominal voltage (one side) from manufacturer = 300 volts (not 330 volts)
Secondary measured off-load voltage = 340 volts
Secondary measured winding dc resistance (one side) = 200 ohms, (not 100 ohms)

Sorry for the values with wrong numbers I posted. All should be good now.
Thanks
Allen