¿ªÔÆÌåÓý

Re: Pat Winlink 2M Packet 1200 baud Setup


 

CORRECTION -
?? I swaped out the Baofeng UV-5R for a 21 year old Kenwood HT
?? NOT a TNC


On Thu, Mar 25, 2021 at 10:13 AM WB2OSZ <wb2osz@...> wrote:
On Thu, Mar 25, 2021 at 08:53 AM, Michael LaBlanc wrote:
However, it seems like my station calls for SAMB, then the RMS returns with the expected RR (ready to receive), but my station ignores this
and sends another SAMB anyway.? Then the RMS sends a DM (Disconnect) command.
RR is not expected at this point.

The station requesting a connection sends SABM until one of the following happens:
- Receive UA frame which means the connection has been accepted.
- Receive DM frame which means the connection has been refused.
- Retry count has been exceeded.

The relevant state diagrams can be found on pages? 86 - 88? here:??


The other station is refusing the connection:

[0.2] K2DLL-10>KC2EHR:(DM res, f=0)

Join [email protected] to automatically receive all group messages.