Georges Tabet
 

Dear?

I am wondering if you can send me the codes for Samsung Anynet + CEC I m using DM-MD 1616 with DMC-HDO and DM-RMC-200
I tried the Crestron module it is not working.
Anynet+ is on on the TV?

Regards?




On Tuesday, September 1, 2015, 23:30, basti76nie@... [Crestron] wrote:

?

No sorry! Only PON and POF and HDMI 1 - 4 worked.
Could you choose the Source TV by CEC?


Re: MC3 - remote Ethernet slave & a local program; at the same time?

 

Just use a EISC. Why 2 MC3's?


Re: BACnet

Mark Conde
 

Yeah that is a bit?different and a perfect case scenario, you have a controller that the thermostats connect to.?
You communicate with the main controller unit, it communicates with the thermostats.
My Situation consists of a thermostat wired directly into the Damper unit itself..


On Sunday, January 31, 2016 1:13 PM, "Joe Vossen jkvossen@... [Crestron]" wrote:


?
Not sure what type of damper unit you are connecting to; I have 5 HAI thermostats connected to a Honeywell zone controller controlling 5 dampers with all of the HAI tstats being controlled through a serial port on a QM-RMC and the QM-RMC talking to a CP3N.....works fine

On Jan 31, 2016, at 12:38 PM, Mark Conde mcjaran@... [Crestron] <Crestron@...> wrote:


Looked at the install instructions for the HAI Thermostat and seems to be design for a standard HVAC Unit.

I need it to control a single zone Damper unit.

Thanks anyways. I appreciate the suggestion.



Re: Emailing from 3-Series

 

Crestron's IP address is added to the whitelist, it just rejects the email because Crestron is trying to authenticate with blank username and password. ?I'm going to try using a 2-series first. ?Hopefully that'll work. ?Otherwise I will try the TEK 3 solution.


Re: Emailing from 3-Series

 

Since you have a server available already, you could install an SMTP relay on the Fusion server that accepts mail from localhost:25 and sends it via TLS/SMTP AUTH to the appropriate host.

On Tue, Feb 2, 2016 at 8:35 PM, jcallaghan0176@... [Crestron] <Crestron@...> wrote:
?

Most?mail servers use TLS and other forms of authentication. The mail server authenticates the username and password and then relays it to the SMTP server. The SMTP server will only allow packets sent from a whitelist.? If you don't have them put the Crestron IP address in that whitelist you will never be able to send mail.

?

We came across this with Fusion. We were not doing exchange integration and wanted to send mail. Fusion only supports SMTP on port 25. There is no way to change it or enable higher forms of authentication. The only work around was to add the Fusion server to the whitelist and allow it to communicate to the mail relay.



Re: Text Entry Field Example (Smart Graphics)

 

Thanks for the response. I'm away from the office without benefit of a processor, so I am not able to test with an xpanel.?


Re: Latest SWAMP firmware: Added doorbell feature capabilities

 

I'll check this tonight when I'm free, thanks for the tips.


Re: Latest SWAMP firmware: Added doorbell feature capabilities

 

it sounds like it might be your CEN-TIA. ??Go into Toolbox and try and try and play the MP3 file and monitor the status. ??I had problems a while back with one running on ENET and had to move it over to Cresnet to make it work reliably. ? ? When it did stop playing on ENET, I could always get the CEN-TIA to work after a power cycle, but just too unreliable for me.


Re: MC3 - remote Ethernet slave & a local program; at the same time?

 

I would use Ethernet Intersystem Communications in SIMPL Windows given that you have 2 MC3s. ?Works awesome.


On Tue, Feb 2, 2016 at 10:23 PM, Lenny Langford lenrex@... [Crestron]
wrote:
?

Just curious.

We have a MC3 in a house running a surround sound system. There is Ethernet running out to their garage which they're turning into an office with a small surround system. I have a Din-switch in the garage for their landscape transformers.

Since we can't do cresnet over a slave box.

Is it possible to use the garage MC3 as a remote Ethernet slave for the AV. Then use a slot on the MC3 for a small D3 lighting program and to talk to the DIN-SW over cresnet?

I know it's possible to have an AV program on slot 1 and lighting on slot 2. Then RSD to the main house MC3. Just wondering if it's possible to use the MC3 as a slave box for AV and also use another slot for lighting/cresnet?

Thanks in advance

Sent from my iThing


MC3 - remote Ethernet slave & a local program; at the same time?

 

Just curious.

We have a MC3 in a house running a surround sound system. There is Ethernet running out to their garage which they're turning into an office with a small surround system. I have a Din-switch in the garage for their landscape transformers.

Since we can't do cresnet over a slave box.

Is it possible to use the garage MC3 as a remote Ethernet slave for the AV. Then use a slot on the MC3 for a small D3 lighting program and to talk to the DIN-SW over cresnet?

I know it's possible to have an AV program on slot 1 and lighting on slot 2. Then RSD to the main house MC3. Just wondering if it's possible to use the MC3 as a slave box for AV and also use another slot for lighting/cresnet?

Thanks in advance

Sent from my iThing


Re: Help!!! Remote CP2E Processor locked up!

 

Yeah tried that and it is a no go. ?I rebooted the AV2 and noticed that someone turn the TV back on so I connect the customer to flip the switch in the cabinet and got the CP2E back on line.


Re: Latest SWAMP firmware: Added doorbell feature capabilities

 

This firmware has broken my previously working doorbell, I am using a room module with interrupt that worked for years now and it works with a CEN-TIA to play a mp3 file but now it seems when I press the doorbell I don't hear my doorbell but if I turn on say AM/FM in a zone and press the doorbell I?then hear it and then it turns off that source and if I press the doorbell again it doesn't work.

Is it possible to revert my SWAMP to the older firmware to fix this? I seriously doubt Crestron will help resolve this and I really don't have time to track down whatever is causing it, before the wife realizes and the bitching starts :-)


Re: Emailing from 3-Series

 

Most?mail servers use TLS and other forms of authentication. The mail server authenticates the username and password and then relays it to the SMTP server. The SMTP server will only allow packets sent from a whitelist.? If you don't have them put the Crestron IP address in that whitelist you will never be able to send mail.

?

We came across this with Fusion. We were not doing exchange integration and wanted to send mail. Fusion only supports SMTP on port 25. There is no way to change it or enable higher forms of authentication. The only work around was to add the Fusion server to the whitelist and allow it to communicate to the mail relay.


Re: Proper procedure of uploading project to MLX-3

 

I have to add some features to my home remote and I'm going to try that instead. Thanks.


Re: Proper procedure of uploading project to MLX-3

 

That makes sense.

Thank you


Re: Text Entry Field Example (Smart Graphics)

 

Any reason you can't test with an xpanel first?
There really is not that much to it.
Set your serial join for the text output from your panel. Optionally set a serial join if you want to send some prompt text to the field.
Ensure Launch Keyboard is checked and you should be good to go.

If you've are unfamiliar with SG Xpanel. Simply compile your project as a standard panel as you would normally do. In the output window at the bottom of vt-pro double click the output file name and Windows will open an explorer window straight to the folder where your vtz is. Double click the vtz to launch the Xpanel. You then have an option in the Xpanel menu called Faceplate. Enable that and all your soft buttons will work just like a real panel.

Don't forget to set your ip address and ip id the same as your real panel.

-slip


Re: c2n-amp-4x100 dead?

 

¿ªÔÆÌåÓý

If NOTHING has changed in the system then do as suggested.? Pull all the inputs and see if the noise is still there.? Then pull one output at a time.? Not sure what else is in the rack but try pulling the coax inputs off the cable boxes. You could be grabbing ground loop from the street.? If all else fails start looking at the amps power supply for swollen/leaking electrolytic capacitors.
?
In a message dated 2/2/2016 9:50:28 A.M. Eastern Standard Time, Crestron@... writes:

?

In Addition to Michael's suggestion of a ground loop... Try disconnecting _everything_ (inputs and outputs) and adding things back one at a time (one source and one output) to see if perhaps something up or downstream has made it particularly unhappy.



--
Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Gold)
ControlWorks Consulting, LLC
V: 440.449.1100 x1107 F: 440-449-1106 I: http://www.controlworks.com
Crestron Services Provider | Biamp Audia Certified | Extron Authorized Programmer


-----Original Message-----
From: Crestron@... [mailto:Crestron@...]
Sent: Tuesday, February 02, 2016 2:15 AM
To: Crestron@...
Subject: [Crestron] c2n-amp-4x100 dead?

Yesterday everything was working just fine. I made no changes to any programs or configuration, but today I just get a buzz (medium pitched similar to one of those annoying scooters, varies with volume) out of all channels. I have tried the obvious, unplug from main, leave it a while, reload firmware, but no change. I can¡¯t even claim that it is tired and sh4gged out after a prolonged squawk, t¡¯s only ever been used for internet radio, some dinner music and such via ceiling speakers.

Does anyone have any idea what else I might be able to try before I declare it demised?

------------------------------------
Posted by: Marc Nield
------------------------------------



Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the Database area.

------------------------------------

Yahoo Groups Links




Re: Emailing from 3-Series

 

There is no display. ?It is basically a panic button setup that will send emails to particular people when a button is pressed.

The TEK 3 looks like it may work. ?I've never heard of it before. ?I didn't see any software on the site...is it just setup through browser? ?Also, would it allow the IT guys access to change email subject matter through browser?

Thanks


Re: Crestron App for iPad

 

And how much was that other purchase? Many are finding Apple won't charge the $100 needed because of limitations on the account.?

Every app deal I've done there have been no issues in doing in-app purchase.?


Re: Toolbox (ish)

 

Running Windows apps in Linux with Wine or a Virtual Machine? It's not even all stable in Windows so I'm not sure I'd touch them in Linux.

It really depends what you want to use Toolbox for. Most info in Toolbox is all available from console connections to devices, and newer products can have firmware and projects loaded with FTP.