Keyboard Shortcuts
Likes
- Crestron
- Messages
Search
Re: Samsung UN series RS232
I've seen the opposite of Phil, but I think it has to do with certain models.? I can successfully control Samsungs with 232 ports on processors or DM receivers.? Almost every one that has been connected to a 1-way IR/Serial?port, I've had to go back and convert to IR.? We just received an email last week that IP control is now enabled in all 2017 models with the latest firmware update.? The email contained a "protocol sheet" which didn't have any useful information, but it also said the Control4 driver was complete and they were working with other control companies to get the drivers done. |
Re: Samsung UN series RS232
Is this one of the Samsungs that uses TTL voltage instead of RS232 voltage? I've run into that before had had to use 1-way serial of an IR port.? On Jun 20, 2017 8:56 PM, "j.thatcher135@... [Crestron]" <Crestron@...> wrote:
|
Re: Samsung UN series RS232
Hey galcala,
Any chance you found a resolution? Samsung told me my crestron processor was incompatible and I feel that this is just untrue as everything else works correctly (Power On/Off / Volume Mute), Im not using a module and using an SIO with the commands from this document ?(http://redirect.viglink.com/?format=go&jsonp=vglnk_149800634791315&key=e38f30e76e63c4c37918771f1bf2c36c&libId=j46ab6ex010004jc000DAaqdt2oa2&loc=http%3A%2F%2Fwww.remotecentral.com%2Fcgi-bin%2Fmboard%2Frs232-ip%2Fthread.cgi%3F603&v=1&out=https%3A%2F%2Fdl.dropboxusercontent.com%2Fu%2F17957951%2FSamsung%2520TV%2520RS232%2520Codes.zip&ref=https%3A%2F%2Fwww.google.com%2F&title=RC%3A%20Samsung%20TV%20RS232%20Codes%20for%20Ex-Link%20(Page%201%20of%204)&txt=dl.dropboxusercontent.com) I am also using a UN series monitor. Specifically a UN85JU7100.? ? I'm waiting to hear back from Samsung if I hear anything I will update the thread. |
Honerywell 4232CBM v1.4 - buffer overrun?
using this module to talk to a Vista 21 IP I get correct status, but am receiving way too much data from the system and getting buffer overrun errors to the tune of 1000's per day I increased the buffer from 1000 to 2000, got the same issue the alarm is just sending data the module doesn't want to process dealer has checked the alarm system twice per the info included in the module help ?mark |
Re: Samsung UN series RS232
I have this exact same issue. Does anyone have a resolution??
When i pull power and re apply power to the display, for a small period of time i get a graphical overlay over whatever source is up and see the volume being adjusted. Than it eventually just goes to a black screen, but i can see the volume being adjusted, before it cuts back to the image. Ideas? |
Re: Control of a Crestron Lighting with a Lutron API
the only thing missing, for reliability sake...is maybe push all the commands out to a cloud based server first and then route it all back via a free DDNS service, making sure to use host names instead of static IP.??
You do realize there is a reason Apple Campus went with Crestron and NOT Savant right??!!! |
Re: SWAMP Zone Name
¿ªÔÆÌåÓýOr SBUF...depends on what you're up to.Sent from my mobile. Please excuse brevity and any typos. Caleb Radecky |?Manager, Online Products & Services Crestron Silver Certified Programmer | DMC-D-4K | DMC-E-4K ControlWorks Consulting, LLC |?Crestron Services Provider?| 701 Beta Dr. #22 Cleveland OH 44143 P.440.449.1100 X1109 | F.440.449.1106 |http://www.controlworks.com -----Original Message-----
From: Kol Johnson kol.mstc@... [Crestron] [Crestron@...] Received: Monday, 19 Jun 2017, 20:52 To: Crestron@... [Crestron@...] Subject: Re: [Crestron] Re: SWAMP Zone Name ?
ABUF the analogs as well?
From: <Crestron@...> on behalf of "steve@... [Crestron]" <Crestron@...>
Reply-To: <Crestron@...> Date: Monday, June 19, 2017 at 5:17 PM To: <Crestron@...> Subject: [Crestron] Re: SWAMP Zon e Name ?
Make sure the SWAMP is fully initialized before the strings are sent. I usually put the "device_ready" pulse into a delay that drives the msend for the strings. |
Re: SWAMP Zone Name
ABUF the analogs as well? From: <Crestron@...> on behalf of "steve@... [Crestron]" <Crestron@...> Reply-To: <Crestron@...> Date: Monday, June 19, 2017 at 5:17 PM To: <Crestron@...> Subject: [Crestron] Re: SWAMP Zone Name ?
Make sure the SWAMP is fully initialized before the strings are sent. I usually put the "device_ready" pulse into a delay that drives the msend for the strings. |
Re: Control of a Crestron Lighting with a Lutron API
I read it as he wants to tell Savant that it is controlling a Lutron system because they don¡¯t have a profile for Crestron lighting, then use a module in Crestron to decode the ¡°Lutron-ese¡± and run the lights. From: <Crestron@...> on behalf of "steve@... [Crestron]" <Crestron@...> Reply-To: <Crestron@...> Date: Monday, June 19, 2017 at 1:28 PM To: <Crestron@...> Subject: [Crestron] Re: Control of a Crestron Lighting with a Lutron API ?
>Don't make it more difficult than it needs to be. He wants a?Lutron system, that is being controlled from Savant,?to control Crestron lighting. ?Importing the Lutron XML won't help with that until he puts the necessary hooks in place on the Crestron side of things. ?
|
Re: Heatmiser via RS-485
Hi Fred, I just tried to DM you, but it bounced, so here's the message: ? Call anytime!! I would put a bet on this being a cabling issue somewhere - maybe a leg tied to ground or mixed up polarity along the way somewhere. ? Unfortunately, I was going to suggest what you said you can't do - wire a stat directly (i.e. No UH-1, no other stats, no star wiring or daisy chains) and check that works.? If it does, then it's a process of elimination. ? We had a report of a faulty stat showing similar behaviour btw...? I? was told they were an older rev of Heatmiser's firmware - though I found that hard to believe as it hasn't changed in *years*. ? Speak soon, Ol P.S. I know this might seem a bit extreme, but we have a little USB digital oscilloscope/logic analyser (cost around ?200) which can save a lot of head scratching in these sorts of situations - you can categorically say whether the +VE/-VE lines are behaving on the Tx phase that way (or you might see one line doesn't mirror the other, which suggests an issue) and if that looks correct (i.e. the two traces are almost perfect mirrors of each other) then the most likely explanation the stat itself failing to respond (which could be bad hardware, or this "old" firmware!?) |
Heatmiser via RS-485
Hi folks,
I'm attempting to control some Heatmiser Slimline-N thermostats via Crestron but I'm not receiving any Rx comms whatsoever...not even garbage...pure silence. There are five Heatmiser UH-1 manifolds to which roughly five or six thermostats are connected. The Heatmiser TouchPad is not in use with this system, control is to be solely from Crestron. I've tried the following:
I'm using version 3 of Ultamation's Heatmiser (RS485) module. So Oliver, if you're reading this expect a call from me soon...I must be missing something. Any assistance greatly appreciated. I've exhausted all possibilities. Best, Fred. |
Re: SWAMP Zone Name
¿ªÔÆÌåÓýChange the serial string? ? Caleb Radecky |
Manager, Online Products & Services ? From: Crestron@... [mailto:Crestron@...]
Sent: Monday, June 19, 2017 11:53 To: Crestron@... Subject: [Crestron] SWAMP Zone Name ? ? How do I name/rename zones?? I've scoured the Sonnex tool and can't figure it out.? I've done it before...
|