Re: Sensibo and crestron stopped working
开云体育Thanks for the thoughts. ? Especially thank you to jbasen for your thoughts. ?
The strange thing is that I have updated nothing. ? I haven’t touched the code or firmware in the cp3 ( yes not a cp4). The certificate on the cp3 is self signed and has an expiry date of 2074. ?
I am wondering if the sensibo has updated its firmware automatically and has an issue with the self signed crestron certificate.?
I’m also trying to work out if the error message is a result of the sensibo not liking the certificate in the crestron cp3 or if it’s a result of the crestron cp3 not liking the certificate on the sensibo. ??
On 26 Mar 2025, at 4:39?am, jbasen via groups.io <jay.m.basen@...> wrote:
|
Re: Sensibo and crestron stopped working
toggle quoted message
Show quoted text
|
Re: Sensibo and crestron stopped working
I'm well above my pay-grade here, so this is just a possible musing...
?
Did you upgrade to some of the most recent FW (I'm assuming this is a CP4)??
There's some issues with HomeKit, DSC, etc. that these newer FWs break related I think to certificate management.
I don't use these interfaces but I'm sure if I updated my CP4's it would break something that they haven't identified, and maybe this is your issue...
I've been staying on the "cp4_2.8003.00056.01.puf", as it seems to be *reasonably* stable...and you know what 'reasonably' means...:)
?
Just throwing this out as a possibility... |
Re: HD-MD8X2 questions
What do you have to configure via the front panel to make it work? On Tue, Mar 25, 2025 at 6:51?AM stefuel2 via <stefuel=[email protected]> wrote:
|
Re: Sensibo and crestron stopped working
开云体育I'm glad you've found the Sensibo module helpful.? Unfortunately, I don't know that I'm going to be helpful solving this problem.? I'm just not well versed in certificates and how Crestron handles them on a processor.?? I have a NAS drive where windows complains about the drive's certificate and the manufacturer can't even give me a straight answer on solving the problem. My one thought would be to update the firmware on the processor to see if that would update the certificate.? However, I believe there are other people on the forum who know much more about this topic than I do. I wish I could be of more help Jay On 3/25/2025 12:40 AM, gbnet.hifi via
groups.io wrote:
|
Re: HD-MD8X2 questions
I've been away from this project for a while, spending time on the actual construction project.? It does work almost perfectly but been having one little glitch.? Upon power up, I have to configure it via front panel buttons then it responds correctly until there's a power outage or a reboot.? If I drop a "1" on "save settings", will that solve the issue?? The system will have a UPS along with a automatic standby generator.? That just leaves the occasional reboot to mess things up.
How do I post a picture here?? I don't see that option.? I'd post a picture of the entertainment center I built for him that will have everything in it to supply the two rooms connected to it. |
Sensibo and crestron stopped working
I am hoping that @jbasen will see this.?? I have been using your sensibo module for a few years and it has been working fantastically well.
?
Today the module has started erroring.?? Seems to be an SSL issue.
?
The error is:
?
00:20:29.047: [Console Data] : Sensibo_Air - Refresh - Error Sending Device Command: Crestron.SimplSharp.Net.Https.HttpsException: Peer certificate cannot be authenticated with given CA certificates
00:20:29.047: [Console Data] : ? ?at Crestron.SimplSharp.Net.Https.HttpsClient.ProcessInternalError(HttpsClientResponse response) 00:20:29.047: [Console Data] : ? ?at Crestron.SimplSharp.Net.Https.HttpsClient.d(HttpsClientRequest A_0, Boolean A_1) 00:20:29.047: [Console Data] : ? ?at Crestron.SimplSharp.Net.Https.HttpsClient.TryDispatch(HttpsClientRequest aRequest) 00:20:29.047: [Console Data] : ? ?at Crestron.SimplSharp.Net.Https.HttpsClient.Dispatch(HttpsClientRequest aRequest) 00:20:29.047: [Console Data] : ? ?at Sensibo_Air_Integration.Sensibo_Air.Refresh() 00:20:29.047: [Console Data] : ? ?at Sensibo_Air_Integration.Sensibo_Air.Initialize(String Device_ID, String API_Key, Int16 Default_Target_Temperature, String Default_Temperature_Unit, Int16 Debug) 00:20:29.047: [Console Data] : ? ?at UserModule_SENSIBO_AIR_V1_6.UserModuleClass_SENSIBO_AIR_V1_6.INITIALIZE_OnPush_0(Object __EventInfo__) 00:20:29.047: [Console Data] : ? ?at Amib.Threading.Internal.WorkItem.o() 00:20:29.047: [Console Data] : ? ?at Amib.Threading.Internal.WorkItem.Execute() 00:20:29.047: [Console Data] : ? ?at Amib.Threading.SmartThreadPool.e(WorkItem A_0 ?
Thanks |
Re: HD-MD8X2 questions
Just a heads up, "Save Settings" is a rising-edge-pulse activated control.? Putting a 1 there will make it save settings at program start, and then never again.
You can put a 1 in "Video Enter" but you need an analog signal in VideoOut1.? If you're controlling from a touchpanel, you'll need to use an Analog Initialize symbol to convert the digital button presses to setting 1d thru 8d of the Analog Signal going into VideoOut1.
?
Like this:
![]() ?
If you want it to autoswitch, I'd run the "Video_Detected_x_fb" feedback joins through logic wave pulses and then into another analog init that pushes to the same analog signal. |
Re: CH and Caseta - Can I? How?
toggle quoted message
Show quoted text
|
Re: HD-MD8X2 questions
I am having sort of a similar situation.? I have and HD-MD8x2 that I am trying to get to auto switch.? I have enter 1 onto the "VideoEnter" field, as well as onto "Save_Seetings" and "VideoOut1".? When I start my program it defaults to Input2 to Output1, since the touch panel is set to select Computer as its initial source.? It displays Input2 just fine, but when I select other inputs from the touch panel the switch stays at Input2. |
Re: Amateur Question: duplicating IP-ID not working?
开云体育Check the GUI extenders in Simpl Windows, make sure that the program 2 versions have all of the same signals that program 1 version has. ?For that serial that shows an IP address, follow the signal back through the program (F2) and see what is supposed to be setting the value (also do same with the analog) as it seems that in program 2 there is a problem with those values being set properly.
|