开云体育

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Re: MidAtlantic RackLink Issue

 

Reach out to MA support, they have new firmware for this


Re: MidAtlantic RackLink Issue

 

Hi Thomas,
*** In your post, you call out the "PDX-215c" model vs the?RLNK-215...
The PDX does not even have an ethernet port on it so I'm hoping that you miss-typed...

Assuming that you're controlling a controllable unit (RLNK models):
First, feel free to reach out to me directly if you want to chat about the specifics of your install...
Second, as mentioned I have used this module successfully with the RLNK-915R units, but have not used it with the?RLNK-215, though it should be the same.
I worked with MAP over the last couple years to sort out IP/Firmware issues with the initial (v01.02) and and interim (v01.10) versions. both had issues with DHCP and Static addressing schemes after a hard boot.

The current firmware version (v1.14.02 Release) has been solid. This would be the first place I would start, by verifying that you're running this version.
NOTE: the upgrade process will be messy regarding the IP address, so you will want to be on-site and be able to do IP scans to find the unit, etc...

HTH




Re: MidAtlantic RackLink Issue

 

Hi Thomas,
I'm late for a meeting right now, but will chime in later. I've integrated with the 915R models very successfully over the last few years, and have good contacts inside MAP.
Standby...


Re: KNX alternatives to the CGEIB-IP?

 

On Fri, Sep 22, 2023 at 11:48 PM, Devin Cook wrote:
It appears that the?CGEIB-IP is limited to something like 500 addresses, which may be why it has proven to be unstable for us.? The system we are connected to needs closer to 2000.

About 10 years ago I wrote code around a KNX Gateway, but I assume that device is no longer in production, though I would have to dig through very old docs to even figure out what the device was.?

Are there alternatives I should be looking at?
By the way, we still have one new CGEIB-IP in stock for a possible replacement for old objects. If necessary, we can sell it.


Re: KNX alternatives to the CGEIB-IP?

 

Hi!

We use Weinzierl BAOS774 (1000 KNX data points) for Crestron-KNX Integrations.?

You can write a module for this gateway yourself or use our commercial module.


Re: MidAtlantic RackLink Issue

Michael S Moran
 

开云体育

Mr. Thomas,

?

Sorry to learn of your trials and tribulations.? I have no personal experience with Middle Atlantic’s IP controlled power products and therefore cannot offer

And meaningful observations or solutions.?

?

That said, I am quite familiar with SnapAV’s product line and they work exceedingly well. ?As a matter of record, I received an email this very morning about

A client’s hacienda going offline.? We had continuous rain and lightning storms over the weekend.? As a possible alternative, Crestron now offers these very

Same appliances in their product assortment.? I have no experience with their version either/yet.

?

Feel free to contact me, personally if I can offer any other insights….

?

U. of F. Alumnus 1972

?

Best regards,

?

Michael? S. Moran

?

?

?? Office:?? 561.391.1843

?

From: [email protected] <[email protected]> On Behalf Of Thomas Herb
Sent: Monday, September 25, 2023 1:23 PM
To: [email protected]
Subject: [crestron] MidAtlantic RackLink Issue

?

Hi,

?

I have a ? to control power.

?

I am using to control it.

?

Running on a CP3.

?

Works fine for a while then the unit stops responding. Won’t turn outlet on after some period of rest.

?

The modules continues to send the command but there is no reply from the device.

?

The TCP/IP client “Connect” input is high.

The TCP/IP client “status” is 1 (waiting).

The TCP/IP client “Connect-F” is low. Of course.

?

IP table TCP/IP client says “waiting”.

?

The PDX-215c unit can ping the processor and the processor can ping it, they are both online and can see each other.

?

Anyone have a suggestion?

?

Anyone else use these things and have working code?

?

Especially for a 4 series since the current module is 2 or 3 series only?

?

Have a Great Day,

?

?

Thomas (Trey) Herb M.A. Ed., CTS

A/V Systems Manager

Warrington College of Business
University of Florida

Bryan 232D

(m) 352-294-2199

?

?

?


MidAtlantic RackLink Issue

 

开云体育

Hi,

?

I have a ? to control power.

?

I am using to control it.

?

Running on a CP3.

?

Works fine for a while then the unit stops responding. Won’t turn outlet on after some period of rest.

?

The modules continues to send the command but there is no reply from the device.

?

The TCP/IP client “Connect” input is high.

The TCP/IP client “status” is 1 (waiting).

The TCP/IP client “Connect-F” is low. Of course.

?

IP table TCP/IP client says “waiting”.

?

The PDX-215c unit can ping the processor and the processor can ping it, they are both online and can see each other.

?

Anyone have a suggestion?

?

Anyone else use these things and have working code?

?

Especially for a 4 series since the current module is 2 or 3 series only?

?

Have a Great Day,

?

?

Thomas (Trey) Herb M.A. Ed., CTS

A/V Systems Manager

Warrington College of Business
University of Florida

Bryan 232D

(m) 352-294-2199

?

?

?


Re: Has anybody used Webhook Relay with IFTTT with a double NAT ISP?

 

Thanks for the advice. It was much easier than I thought it would be. I do tend to overcomplicate things, so it's nice to know there's a simple solution out there?


Re: SPDIF over ethernet/cat5

 

Muxlab 500086 has worked well for me on a number of projects. Does Toslink also and can convert between them. Power on either end.?


Re: Switchbot Meter / Meter Plus

 

That seems to work.? Thanks so much!


Re: Switchbot Meter / Meter Plus

 

开云体育

I believe this will work for you

Thanks

Jay

On 9/24/2023 4:20 PM, Jay R. wrote:

No rush at all. You do so much for the community and I for one really appreciate it.?

On Sun, Sep 24, 2023 at 3:08 PM jbasen <jay.m.basen@...> wrote:

Sigh.? I'm going to have to pull out one and do some debugging.? I may be able to get to it this evening.? Otherwise, given my schedule that might take a day or 2

On 9/24/2023 3:25 PM, Jay R. wrote:
Thanks Jay, this definitely improved the connection, but the devices look to report good data but the temp outputs as 320 and 0 for humidity.

SwitchBot - Get_Meter_State - URL:
SwitchBot - Security_Test - time = 1695589196192
SwitchBot - Security_Test - nonce = 820aa91f-4acb-4873-adec-8545f0e3a9d5
SwitchBot - Security_Test - signature = +bkZ15IxdhCsSVpAkn37t5wEHhUW8aV6LFweoLFPv0c=
SwitchBot - Get_Meter_State - Success - response.ContentString = {"statusCode":100,"body":{"deviceId":"ED6743015676","deviceType":"Meter","hubDeviceId":"CC34350F1FD7","humidity":33,"temperature":26.7,"version":"V2.8","battery":100},"message":"success"}
SwitchBot - Get_Meter_State - Temperature = 320, Humidity = 0

The meters and Indoor/Outdoor Hygrometers (deviceType":"WoIOSensor) and Hub2 all seem to report back accurately it just doesn't output to the analog signal correctly.

I really appreciate your help.


Re: Switchbot Meter / Meter Plus

 

No rush at all. You do so much for the community and I for one really appreciate it.?

On Sun, Sep 24, 2023 at 3:08 PM jbasen <jay.m.basen@...> wrote:

Sigh.? I'm going to have to pull out one and do some debugging.? I may be able to get to it this evening.? Otherwise, given my schedule that might take a day or 2

On 9/24/2023 3:25 PM, Jay R. wrote:
Thanks Jay, this definitely improved the connection, but the devices look to report good data but the temp outputs as 320 and 0 for humidity.

SwitchBot - Get_Meter_State - URL:
SwitchBot - Security_Test - time = 1695589196192
SwitchBot - Security_Test - nonce = 820aa91f-4acb-4873-adec-8545f0e3a9d5
SwitchBot - Security_Test - signature = +bkZ15IxdhCsSVpAkn37t5wEHhUW8aV6LFweoLFPv0c=
SwitchBot - Get_Meter_State - Success - response.ContentString = {"statusCode":100,"body":{"deviceId":"ED6743015676","deviceType":"Meter","hubDeviceId":"CC34350F1FD7","humidity":33,"temperature":26.7,"version":"V2.8","battery":100},"message":"success"}
SwitchBot - Get_Meter_State - Temperature = 320, Humidity = 0

The meters and Indoor/Outdoor Hygrometers (deviceType":"WoIOSensor) and Hub2 all seem to report back accurately it just doesn't output to the analog signal correctly.

I really appreciate your help.


Re: Switchbot Meter / Meter Plus

 

开云体育

Sigh.? I'm going to have to pull out one and do some debugging.? I may be able to get to it this evening.? Otherwise, given my schedule that might take a day or 2

On 9/24/2023 3:25 PM, Jay R. wrote:

Thanks Jay, this definitely improved the connection, but the devices look to report good data but the temp outputs as 320 and 0 for humidity.

SwitchBot - Get_Meter_State - URL:
SwitchBot - Security_Test - time = 1695589196192
SwitchBot - Security_Test - nonce = 820aa91f-4acb-4873-adec-8545f0e3a9d5
SwitchBot - Security_Test - signature = +bkZ15IxdhCsSVpAkn37t5wEHhUW8aV6LFweoLFPv0c=
SwitchBot - Get_Meter_State - Success - response.ContentString = {"statusCode":100,"body":{"deviceId":"ED6743015676","deviceType":"Meter","hubDeviceId":"CC34350F1FD7","humidity":33,"temperature":26.7,"version":"V2.8","battery":100},"message":"success"}
SwitchBot - Get_Meter_State - Temperature = 320, Humidity = 0

The meters and Indoor/Outdoor Hygrometers (deviceType":"WoIOSensor) and Hub2 all seem to report back accurately it just doesn't output to the analog signal correctly.

I really appreciate your help.


Re: Switchbot Meter / Meter Plus

 

Thanks Jay, this definitely improved the connection, but the devices look to report good data but the temp outputs as 320 and 0 for humidity.

SwitchBot - Get_Meter_State - URL: https://api.switch-bot.com/v1.1/devices/ED6743015676/status
SwitchBot - Security_Test - time = 1695589196192
SwitchBot - Security_Test - nonce = 820aa91f-4acb-4873-adec-8545f0e3a9d5
SwitchBot - Security_Test - signature = +bkZ15IxdhCsSVpAkn37t5wEHhUW8aV6LFweoLFPv0c=
SwitchBot - Get_Meter_State - Success - response.ContentString = {"statusCode":100,"body":{"deviceId":"ED6743015676","deviceType":"Meter","hubDeviceId":"CC34350F1FD7","humidity":33,"temperature":26.7,"version":"V2.8","battery":100},"message":"success"}
SwitchBot - Get_Meter_State - Temperature = 320, Humidity = 0

The meters and Indoor/Outdoor Hygrometers (deviceType":"WoIOSensor) and Hub2 all seem to report back accurately it just doesn't output to the analog signal correctly.

I really appreciate your help.


Re: Switchbot Meter / Meter Plus

 

开云体育

Hi Jay,

I think this will work but I don't have a SwitchBot Meter setup right now to test it myself.? Just replace the SwitchBot.clz file you have with this one, recompile, and let me know if it addresses the issue.

Here is a download link -

Thanks

Jay

On 9/24/2023 2:08 PM, jbasen via groups.io wrote:

Hi Jay,

It's not you it's me.? SwitchBot made a change to their JSON and it broke my parsing.? I'll get an update out as soon as I can.

Thanks

Jay?

On 9/24/2023 9:14 AM, Jay R. wrote:

[Edited Message Follows]

I'm sure I'm doing something wrong but I haven't figured out what.? I recently bought a switchbot and some meters to test out and see if I wanted to try the CurtainBots or BlindTilts.? I seem to be connecting to the switchbots and getting a response but then I get a format exception, I only have meters/meter plus to test with right now.?

Here is the snippet from the console.

DIN-AP3MEX>SwitchBot - Get_Meter_State - URL:
SwitchBot - Security_Test - time = 1695567395089
SwitchBot - Security_Test - nonce = 8eb6bd54-761b-472e-ab56-88389300d959
SwitchBot - Security_Test - signature = PDUPG1DUOVcjMedvxMjFK/Nb4NGk3qSk9NnVRSptjh0=
SwitchBot - Get_Meter_State - Success - response.ContentString = {"statusCode":100,"body":{"deviceId":"XXXXXXXX5676","deviceType":"Meter","hubDeviceId":"XXXXXXXX1FD7","humidity":30,"temperature":26.9,"version":"V2.8","battery":100},"message":"success"}
SwitchBot - Get_Meter_State - Error Retreiving Meter StatusSystem.FormatException: FormatException
?? at System.Double.Parse(String s, NumberStyles style, IFormatProvider provider)
?? at SwitchBot_Integration.SwitchBot.Get_Meter_State(String Device_ID, Int16 Temperature_Format_Selection)
?? at UserModule_SWITCHBOT_METER_V1.UserModuleClass_SWITCHBOT_METER_V1.POLL_OnPush_1(Object __EventInfo__)
?? at Amib.Threading.Internal.WorkItem.o()
?? at Amib.Threading.Internal.WorkItem.Execute()
?? at Amib.Threading.SmartThreadPool.e(WorkItem A_0)
?? at Amib.Threading.SmartThreadPool.p()

Thanks


Re: Switchbot Meter / Meter Plus

 

开云体育

Hi Jay,

It's not you it's me.? SwitchBot made a change to their JSON and it broke my parsing.? I'll get an update out as soon as I can.

Thanks

Jay?

On 9/24/2023 9:14 AM, Jay R. wrote:

[Edited Message Follows]

I'm sure I'm doing something wrong but I haven't figured out what.? I recently bought a switchbot and some meters to test out and see if I wanted to try the CurtainBots or BlindTilts.? I seem to be connecting to the switchbots and getting a response but then I get a format exception, I only have meters/meter plus to test with right now.?

Here is the snippet from the console.

DIN-AP3MEX>SwitchBot - Get_Meter_State - URL:
SwitchBot - Security_Test - time = 1695567395089
SwitchBot - Security_Test - nonce = 8eb6bd54-761b-472e-ab56-88389300d959
SwitchBot - Security_Test - signature = PDUPG1DUOVcjMedvxMjFK/Nb4NGk3qSk9NnVRSptjh0=
SwitchBot - Get_Meter_State - Success - response.ContentString = {"statusCode":100,"body":{"deviceId":"XXXXXXXX5676","deviceType":"Meter","hubDeviceId":"XXXXXXXX1FD7","humidity":30,"temperature":26.9,"version":"V2.8","battery":100},"message":"success"}
SwitchBot - Get_Meter_State - Error Retreiving Meter StatusSystem.FormatException: FormatException
?? at System.Double.Parse(String s, NumberStyles style, IFormatProvider provider)
?? at SwitchBot_Integration.SwitchBot.Get_Meter_State(String Device_ID, Int16 Temperature_Format_Selection)
?? at UserModule_SWITCHBOT_METER_V1.UserModuleClass_SWITCHBOT_METER_V1.POLL_OnPush_1(Object __EventInfo__)
?? at Amib.Threading.Internal.WorkItem.o()
?? at Amib.Threading.Internal.WorkItem.Execute()
?? at Amib.Threading.SmartThreadPool.e(WorkItem A_0)
?? at Amib.Threading.SmartThreadPool.p()

Thanks


SPDIF over ethernet/cat5

 

Hi,

Just looking for a rock solid SDPIF extender over ethernet/UTP with loseless sound quality.
Are there any recommendations from you guys?

Regards
Kamil Rukat


Switchbot Meter / Meter Plus

 
Edited

I'm sure I'm doing something wrong but I haven't figured out what.? I recently bought a switchbot and some meters to test out and see if I wanted to try the CurtainBots or BlindTilts.? I seem to be connecting to the switchbots and getting a response but then I get a format exception, I only have meters/meter plus to test with right now.?

Here is the snippet from the console.

DIN-AP3MEX>SwitchBot - Get_Meter_State - URL: https://api.switch-bot.com/v1.1/devices/XXXXXXXX5676/status
SwitchBot - Security_Test - time = 1695567395089
SwitchBot - Security_Test - nonce = 8eb6bd54-761b-472e-ab56-88389300d959
SwitchBot - Security_Test - signature = PDUPG1DUOVcjMedvxMjFK/Nb4NGk3qSk9NnVRSptjh0=
SwitchBot - Get_Meter_State - Success - response.ContentString = {"statusCode":100,"body":{"deviceId":"XXXXXXXX5676","deviceType":"Meter","hubDeviceId":"XXXXXXXX1FD7","humidity":30,"temperature":26.9,"version":"V2.8","battery":100},"message":"success"}
SwitchBot - Get_Meter_State - Error Retreiving Meter StatusSystem.FormatException: FormatException
?? at System.Double.Parse(String s, NumberStyles style, IFormatProvider provider)
?? at SwitchBot_Integration.SwitchBot.Get_Meter_State(String Device_ID, Int16 Temperature_Format_Selection)
?? at UserModule_SWITCHBOT_METER_V1.UserModuleClass_SWITCHBOT_METER_V1.POLL_OnPush_1(Object __EventInfo__)
?? at Amib.Threading.Internal.WorkItem.o()
?? at Amib.Threading.Internal.WorkItem.Execute()
?? at Amib.Threading.SmartThreadPool.e(WorkItem A_0)
?? at Amib.Threading.SmartThreadPool.p()

Thanks


Re: Panasonic Camera keeps moving after button release

 

I have a trick I use for this, I can send it over to you later today when I am on my computer. Shoot me an email and I can send it to you


Re: KNX alternatives to the CGEIB-IP?

 

开云体育

Hi,

you can use more than one Gateway in an installation to overcome the limitation.

?

Cheers,

Thorsten

?

Von: [email protected] <[email protected]> Im Auftrag von Devin Cook
Gesendet: Freitag, 22. September 2023 22:49
An: [email protected]
Betreff: [crestron] KNX alternatives to the CGEIB-IP?

?

Hello all,

It appears that the?CGEIB-IP is limited to something like 500 addresses, which may be why it has proven to be unstable for us.? The system we are connected to needs closer to 2000.

About 10 years ago I wrote code around a KNX Gateway, but I assume that device is no longer in production, though I would have to dig through very old docs to even figure out what the device was.?

Are there alternatives I should be looking at?