开云体育

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Re: crestron.com online help issue

 

Anyone heard whether they're going to fix this soon??? it's a PITA...


Re: TRANE XL1050 WiFi Thermostats

 

Thanks Jeff for the response - I have confirmed with TB regarding this (another hour wasted on the phone)

Such a Digital Age bummer! I love when I go to finish a project and find that I can't finish the project...:(
I think I have a temporary work-around (one that of course with cost me more $$$) as the developer has indicated that they are working with TRANE to resolve the AUTH issue that apparently was caused by newer processor FW...
I'm hopeful that they will have a fix soon...
The recommended *fix* is to put another 3-series proc in the site with 1.503 FW running the TRANE modules and EISC the signals to the main processor...Arrggghh...

What really frosts me is how we all seem to get blind-sided with this stuff. Did I miss the memo? or should I finally consider it normal to do all the work, trouble-shoot and then find out thru the 'Grape-Vine' that this is the case...

I will make it a point to update here, if/when I get a resolution...


Bose SoundTouch and LifeStyle drivers for Crestron Home OS3? #crestron

 

Hello Guys,

I'm looking for a Bose SoundTouch/LifeStyle driver for Crestron Home OS3, something like the JanusTech ones for SIMPL (which work extremely well btw) but compatible with CH.

Thanks.


Re: Time on TSW-x70 with 4-series processor

 

Thanks for the response! However, my question is primarily about any differences from older setups.

The x60-series panels also had their own time settings BUT with 3-series processors, I never had to touch them. The processor time seemed to be automatically used by the x60's to set their time.
With a CP4/770 I'm not seeing this - thus the question is: Is this a bug, or is there a new 'Best Practice' that Crestron has not spelled out yet...


Re: UC Engine - Multiple platforms

 

My bad. I missed the ‘X’ part of his comment. ?It was a long time coming for biamp to support this. ?Awaiting the next rev of forte to have that built in.?


Method Calling issue from SIMPL+ to SIMPL#

 

I have created one SIMPL SHARP library for CoolMasterNet Control , I am able to control HVAC Unit but unable get Feedback . The actual process is based on User event for example if it Power On the 1st On command is sent to CoolmasterNet the after few millisecond I am sending query command. So for this i have created 2 separate methods in SIMPL sharp (1.Control() 2. Feedback() ) . I have used push event for this. The code is below

PUSH POWER_ON

{

IF(CONNECT\_FB=1)

{

myClass.ClientSend(1,UID,High\_Limit,Low\_Limit,"");      //Only this statement works

cmd = "stat " + UID + "\x0D\x0A";

(14,UID,High_Limit,Low_Limit,cmd);

}

else

{

	Print("\\n Please make connection first");

}

}

?

Only the 1st statement inside the IF loop is working.

Thanks in advance.


LG TV handshaking issue with SIMPL SHARP library

 

I have created one SIMPL SHARP library for LG TV Control. The web socket connection with TV is successful but after that when we start handshaking process the query is sent from our side but there is no response from TV.

Thanks in advance,


Re: Time on TSW-x70 with 4-series processor

 

The x70 series have their own time management settings. If your equipment has access to a time server simply setup the TP's time like you do the processor. In the event your equipment does not have access to a time server AND you provide the user ability to update the time from the TP's I have had success leaving the time service enabled on the TP's but changing the time server to point at the processor, if you don't provide the ability to change the time then just set and forget it like you would the processor.

Chris?


Re: Ubiquiti wifi extender #bestpractices

 

开云体育

Hi,

?

as i understand you want to have LAN at the other end as well, you probably want to ?have a look at a wifi bridge:

?

Cheers, Thorsten

?

Von: [email protected] <[email protected]> Im Auftrag von Brad Wykoff via groups.io
Gesendet: Freitag, 11. Juni 2021 19:54
An: [email protected]
Betreff: [crestron] Ubiquiti wifi extender #bestpractices

?

I have an existing Uniquiti network but need to extend my wifi to a network switch that I'm not able to get any wires ran to this location but equipment needs network.? I have seen Netgear products that allow using existing wifi to extend with a local network port but wanting to keep with Ubiquiti.

Any products that work best.


Crosspoint ECCON on 4-Series

 

Good evening brain trust,
I did a takeover job this week updating a PRO2 to a PRO4. Most of the old logic works just fine, the problem is with new crosspoint logic to replace the old ORs and BUFs. I wrote it the same as many other programs in the past. The EID analog feeds into an AOS (parameter of 1d) with the OUT driving to the CONNECT of the ECCON. The OUT* drives the Disc_From_E. On a program reboot the routes are clear but when switching sources the EID does not disconnect. It will connect to the new EID but keep any previous routes. Even trying the Disc_EC didn't fix it. The only way it would change routes is by using Disc_All which is obviously not a good solution since it clears all routes across the project. Does anyone have any insight into why the Disc_From_E doesn't change the route?


Simpl# Debugging 4-Series

 

Hi All,

I'm trying to debug a SimplSharpLibrary build for 3-Series I have converted to 4-Series, however it is not running as smooth has in 3-Series.
So I followed the 4-Series C# Developpement Instruction from Crestron. It is running fine and I'm able to place breakpoints with Visual Studio 2019 Community and the VSMonoDebugger Extension.

This issue is that I'm not able to inspect the variables as deep as I would like to.

How can I solve this?

Regards,


Time on TSW-x70 with 4-series processor

 

Hi All,
I have always had the Processor time get set to the TSW panels without having to do anything with the TSW panel settings.
I have a new project with a CP4 [v2.5001.00006] and (2) TSW-770s [v1.002.0040] and the panels are stuck at GMT.? The panels have the SG Digital Time Date widget for the time display.
I haven't yet done any different settings on the panels...

Have others seen this, is this a bug, or is there a new 'best practice' in setting this up for correct time display??
TIA!


Re: SIMPL# Question

 

6-11-2021: Does this still work? I'm having problems attaching


Re: Ubiquiti wifi extender #bestpractices

 

I've been looking at their kit recently, Ubiquiti wireless access points seem to have mesh capability


Re: Ubiquiti wifi extender #bestpractices

 

Just get another Ubiquiti Unifi access point and? enable wireless uplinks (usually enabled by default).? They will operate in mesh mode and can be use to get Ethernet to other devices.


Re: Ubiquiti wifi extender #bestpractices

 

Although I wouldn't design a network around this (hard-wared dedicated CAT lines are always best!) I have used the following in a pinch and they do work well:
1. If you have a COAX cable near where you need to add a switch and/or AP, ActionTEC makes an gigabit Ethernet-over-Coax device:


2. If there's absolutely no infrastructure, I have used various HomePlug Ethernet-over-PowerLine products and they seem to work reliably, though I think you won't get full speeds with this. It's actually amazing that this works and works well!!


Ubiquiti wifi extender #bestpractices

 

I have an existing Uniquiti network but need to extend my wifi to a network switch that I'm not able to get any wires ran to this location but equipment needs network.? I have seen Netgear products that allow using existing wifi to extend with a local network port but wanting to keep with Ubiquiti.

Any products that work best.


Re: CP4 versiports "locking up"

 

开云体育

Hi Lincoln,

?

in my case, the CP4 with the issues is running just one program in slot 1.

The other 3-Series without issues running 1-7 programs (the latter being my own home CP3, with program 4 referincing the versiports.

?

Reg. logs:

I just had a look into the errlog and couldn?t find anything suspicious. Any idea what to look for?

?

Adding to the issue:

The customer with the CP4 just reported that his room ventilation just switched to mode 2 which is triggered by an analog compare on the versiport: if CO? reaches a certain level, ventilation is switched on.

However, the actual value reported on the touchpanel was still way below the threshold.

Just mentioning this because there probably could have been a short spike in the readings that triggered the analog compare….

?

Cheers, Thorsten

?

Von: [email protected] <[email protected]> Im Auftrag von Lincoln King-Cliby
Gesendet: Freitag, 11. Juni 2021 16:55
An: [email protected]
Betreff: Re: [crestron] CP4 versiports "locking up"

?

Out of curiousity how many programs are you running on the processor and which of them reference the versaports?

?

Also… To repeat my question from earlier: Anything in the log?

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] <[email protected]> On Behalf Of Jason LeMay via groups.io
Sent: Friday, June 11, 2021 8:25 AM
To: [email protected]
Subject: Re: [crestron] CP4 versiports "locking up"

?

I did a firmware update yesterday on a processor and experienced the same thing, shortly after adding a couple horizon keypads.?

Cp4-r IO’s are connected to simple motion sensors in closets.?

?

The io wouldn’t show open when the motion wasn’t triggered. Lights wouldn’t turn off.?

?

?

On Jun 11, 2021, at 8:05 AM, ian_crestron via groups.io <ian_crestron@...> wrote:

?I also have a very basic sensor hooked up to an IO port on a CP4 - driveway sensor, momentary dry contact, cp4 signal gets stuck high.??
Pull out the connector, signal still shows high, reboot proc and it works for some unknown amount of time again. Having trouble tracking down issue.?
Possible the latest cp4 firmware fixed, I have not heard from the client in a few weeks since we last updated.?


Re: CP4 versiports "locking up"

 

开云体育

My issues from yesterday,?
CP4-R running Home so 1 program.?

On Jun 11, 2021, at 10:56 AM, Lincoln King-Cliby <lincoln@...> wrote:

?

Out of curiousity how many programs are you running on the processor and which of them reference the versaports?

?

Also… To repeat my question from earlier: Anything in the log?

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] <[email protected]> On Behalf Of Jason LeMay via groups.io
Sent: Friday, June 11, 2021 8:25 AM
To: [email protected]
Subject: Re: [crestron] CP4 versiports "locking up"

?

I did a firmware update yesterday on a processor and experienced the same thing, shortly after adding a couple horizon keypads.?

Cp4-r IO’s are connected to simple motion sensors in closets.?

?

The io wouldn’t show open when the motion wasn’t triggered. Lights wouldn’t turn off.?

?



On Jun 11, 2021, at 8:05 AM, ian_crestron via groups.io <ian_crestron@...> wrote:

?I also have a very basic sensor hooked up to an IO port on a CP4 - driveway sensor, momentary dry contact, cp4 signal gets stuck high.??
Pull out the connector, signal still shows high, reboot proc and it works for some unknown amount of time again. Having trouble tracking down issue.?
Possible the latest cp4 firmware fixed, I have not heard from the client in a few weeks since we last updated.?


Re: CP4 versiports "locking up"

 

开云体育

Out of curiousity how many programs are you running on the processor and which of them reference the versaports?

?

Also… To repeat my question from earlier: Anything in the log?

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] <[email protected]> On Behalf Of Jason LeMay via groups.io
Sent: Friday, June 11, 2021 8:25 AM
To: [email protected]
Subject: Re: [crestron] CP4 versiports "locking up"

?

I did a firmware update yesterday on a processor and experienced the same thing, shortly after adding a couple horizon keypads.?

Cp4-r IO’s are connected to simple motion sensors in closets.?

?

The io wouldn’t show open when the motion wasn’t triggered. Lights wouldn’t turn off.?

?



On Jun 11, 2021, at 8:05 AM, ian_crestron via groups.io <ian_crestron@...> wrote:

?I also have a very basic sensor hooked up to an IO port on a CP4 - driveway sensor, momentary dry contact, cp4 signal gets stuck high.??
Pull out the connector, signal still shows high, reboot proc and it works for some unknown amount of time again. Having trouble tracking down issue.?
Possible the latest cp4 firmware fixed, I have not heard from the client in a few weeks since we last updated.?