Sonos dropping offline

 

Have a customer that we took over.? system is 2 rooms with playbars.? There are more Sonos devices in the system, but not that we are controlling.? He added a boost to the system a while back which forced the sonos to update and I did a remote update of the sonos modules to 3.0.? Not sure if the issue is related to the boost, but now the playbars drop offline from crestron control and I am unable to get it back without a reboot of the processor.? Wanted to reach out and see if anyone else had experienced this issue.


Processor is a DIN-AP3EX updated with latest firmware the other day.


Re: Vaddio RoboSHOT 30 TCP/IP Control

 

I appreciate it either way I will try that module. I have tried a couple others but not this one. I am mainly an anti-module programmer as I find Modules tend to do things that I don't want them to do and I cannot control it. I prefer to be able to control at all costs even if it means I have to do 40 blocks and 50 lines of programming compared to a single line in a module. I also looked inside the 3 modules and there wasn't clarification to me on what they were doing to get the functions to work. In the end I will attempt this one. Thanks for the quick response.


Re: Vaddio RoboSHOT 30 TCP/IP Control

 

TCP/IP control on the Vaddio cameras does require a login to establish a full connection.? Not sure if you are doing this or not.? When I have controlled these cameras in the past, I setup a macro to login upon the TCP/IP connection.? Once that done, the protocol in the user manual should work fine.


Re: Vaddio RoboSHOT 30 TCP/IP Control

 

Didn't understand your original message on first reading. Sounds like you've already got a module but it won't work. Maybe you could look at the module from the application market and see what they are doing.


Re: Vaddio RoboSHOT 30 TCP/IP Control

 

There is a module on the application market that I have used for tcp/ip control of a roboshot. It is listed for another vaddio camera, but I've found that all the basic controls work on several different models.



Vaddio RoboSHOT 30 TCP/IP Control

 

I have a RoboSHOT camera that I am attempting to control via TCP/IP. I have read the manual on the Camera for control information and the code they give me in the manual does not appear to work. I am utilizing TCP/IP Client and Serial I/O blocks to achieve this as when I attempt to put in a camera Module it does not allow me to upload the project to the CP3N.


Re: audio loss on Samsung TVs with One Connect

 

I recently had an issue very similar with Samsung tvs, either the DM switcher or the sources didn't like the EDID from the samsung display.? I loaded a Crestron default EDID to the switcher and it fixed the issue.


Re: Bypass auto start/stop

 

Thank you!


Sonos Party Mode

 

Does anyone know if there is an easy way to initiate party mode on SONOS?? I would like to build a button that goes out an puts every speaker on the same group (on the SONOS app, it is Select All - Party Mode).


Re: CLW-DIMEXP Air Gap Switch

 

I have the same issue at my house. Some of my switches seem much more susceptible than others to this issue.??


Re: CLW-DIMEXP Air Gap Switch

 

¿ªÔÆÌåÓý

FWIW, I¡¯ve noticed this when switch itself or switch plate is screwed in too far, usually after electrician has done the install and our crew has done the engraved buttons weeks later

Trey

On Jan 9, 2019, at 12:41 PM, Jonny ComeAlive@... [Crestron] <Crestron@...> wrote:

?

Had this happen yesterday. It seems that the switch slid to the left and get caught under trim.?


On Jan 9, 2019, at 12:39 PM, doug1369@... [Crestron] <Crestron@...> wrote:

?

anyone else have problems with the air gap switch getting stuck in the open position, I think that people are just hitting the bottom of the switch to turn it off, and then on accident hit the airgap switch also and then whole home scenes show the wrong feedback because it is open, any solution other than super gluing it shut? seems to happen on the switches that are multi-ganged, on uneven services and such. I have tried to get the switches perfectly flush on the wall etc. but it keeps happening.



Re: CLW-DIMEXP Air Gap Switch

 

¿ªÔÆÌåÓý

Had this happen yesterday. It seems that the switch slid to the left and get caught under trim.?


On Jan 9, 2019, at 12:39 PM, doug1369@... [Crestron] <Crestron@...> wrote:

?

anyone else have problems with the air gap switch getting stuck in the open position, I think that people are just hitting the bottom of the switch to turn it off, and then on accident hit the airgap switch also and then whole home scenes show the wrong feedback because it is open, any solution other than super gluing it shut? seems to happen on the switches that are multi-ganged, on uneven services and such. I have tried to get the switches perfectly flush on the wall etc. but it keeps happening.



CLW-DIMEXP Air Gap Switch

 

anyone else have problems with the air gap switch getting stuck in the open position, I think that people are just hitting the bottom of the switch to turn it off, and then on accident hit the airgap switch also and then whole home scenes show the wrong feedback because it is open, any solution other than super gluing it shut? seems to happen on the switches that are multi-ganged, on uneven services and such. I have tried to get the switches perfectly flush on the wall etc. but it keeps happening.



Re: Embedded Video Object - MJPEG/H.264

Heather Baiman
 

¿ªÔÆÌåÓý

Thanks, but that is rtsp

?

I reached out to a smarty at Axis and they told me for mjpeg:

?

?/streamprofile=profilename

?

I was waiting till we get back on site to test the string before I updated the group though.

?

From: Crestron@... <Crestron@...>
Sent: Wednesday, January 09, 2019 12:40 PM
To: Crestron@...
Subject: [Crestron] Re: Embedded Video Object - MJPEG/H.264

?



rtsp://<user:pass>@<IP>/axis-media/media.amp?Profile='profile name'?



Re: Embedded Video Object - MJPEG/H.264

 

rtsp://<user:pass>@<IP>/axis-media/media.amp?Profile='profile name'?


Re: DMC-4KZ-C-DSP Audio output into an Avia 1280

 

If you are doing stereo, you can wire unbalanced to balanced on the DSP. Each channel gets their own input on the DSP. If you only need mono, you can use an OWI Amp-Stcomb with a RCA to 3.5mm TRS into a single balanced input on the DSP.?

On Wed, Jan 9, 2019 at 9:04 AM charles.perkins@... [Crestron] <Crestron@...> wrote:
?

What are my options for connecting the?DMC-4KZ-C-DSP (or any of the DMC cards) Audio output into an Avia 1280. I found the TX-J2 but would like to see what other options I have.


I'm using the 8 outputs of DSP to drive the inputs of the AMP-8150.


Thanks


Re: Cisco

 

No, It can send out proprietary button press commands to a control system that can then in turn send out IP commands to a Display.?

The only display control a cisco codec has is CEC.


DMC-4KZ-C-DSP Audio output into an Avia 1280

 

What are my options for connecting the?DMC-4KZ-C-DSP (or any of the DMC cards) Audio output into an Avia 1280. I found the TX-J2 but would like to see what other options I have.


I'm using the 8 outputs of DSP to drive the inputs of the AMP-8150.


Thanks


Re: Bypass auto start/stop

 

With bypass on, nothing unusual happens when you load a program -- only that slot gets restarted.

With bypass off, if you load Program1 and you also have a Program2 loaded, Toolbox will stop Program2 while it uploads Program1, then restart it afterwards.? Higher numbered programs are arbitrarily considered "dependent" on lower numbered programs.

I've never seen a good reason to have bypass off.


On Wed, Jan 9, 2019 at 9:40 AM crestron_programmer@... [Crestron] <Crestron@...> wrote:
?

Hi All,


Can someone explain what this actually means in the upload program window? "Bypass auto start/stop of dependent programs


Thank you,


Experience with Crestron VC-4 Core?

 

Has anyone used the new Crestron VC-4 Core yet? What's your experience like? Pros and Cons of it? Thank you.