In the app, did you press the pencil, press the entry you are using,? scroll down to the botton of the config for Address1 and Address2 and turn on ¡°Watch/Widget¡± slider to ¡°On¡±, default is off.

?

Trey

?

From: Crestron@... [mailto:Crestron@...]
Sent: Saturday, January 14, 2017 8:03 AM
To: Crestron@...
Subject: [Crestron] Crestron Today issues

?

?

Hi all

Having some real issues with the "Crestron Today" notification view/watch widget.

I have an MC3 running 1.501.0105, and the paid SG (Silver) app running on a phone and an iPad.

In Simpl Windows, I've obviously got my "Crestron App Notification Widget Functions" extender added to my "Crestron App". For now, I have defined all 10 of my "item X pressed" joins, have an analog with a value of 10 going into "number of items" (this is set at boot) as well as 10 fields of text and the header going into the serial joins (again, set at boot)

For now the panel layout is loaded to the iPad and the iPhone locally and the full panel works perfectly. I have routed the joins to a test page and i can see the text and the value of the analogs has been set.

?

When i go to the notification view widget on the phone or ipad, or a watch paired with the phone, i just get "Not Configured" as the header, and on the watch, "Not Configured" along with 10 blank buttons.

?

I read about database version being newer than 70 - I am running:-

?

SIMPL Windows:? 4.05.04
SIMPL+? 4.04.01
Device Database: 81.00.002.00
Crestron Database:? 60.05.007.00
Crestron Toolbox: 2.42.541.00
SIMPL+ Cross Compiler: 1.3

Any ideas what I have missed?!

?

?

Cheers


Re: Active CNX UpdateRequest

 

>> Eventually I think I might build a Node.js implementation of Active CNX in case anyone is interested

I am most certainly interested in anything Node.js <-> Crestron


Fusion room

 

Hi guys,
1- I have system using. Dmps 300-c (more than 10)
2- I make program have fusion room and room view
3- 5 out of 10 not work right with fusion only
4- work good with room view
5- dmps remaining is work good with fusion
Problem is
No data send from fusion
Feedback is ok
Only in some dmps

Any one can help me to solve this problem


Re: PC Control via Crestron

 

I have been using MCE controller for a long time, and it works great to send keyboard commands through. Does other things as well.

?






Re: PC Control via Crestron

 


On Sat, Jan 14, 2017 at 9:20 AM, FBC Tech Team <sound@...> wrote:
We didn't really care for the Crestron TCP module so our SW programmer wrote his own.

I spoke to our SW eng and he added some more info on my comment above:

"The main reason we did our own TCP Client was that the CRESTRON one would not handle strings longer than 255 characters. We needed to pass longer ones to the SVSi decoders for IR (pronto code) control of the Stingray boxes.?Up to that point we had been using the CRESTRON modules.?However, I like to know what a module is doing so writing your own is a plus in my book."

Hope that helps,
Jeff

-------------------------------------
Jeff Klein, DMC- E
Audio Visual Project Manager
Dept of Defense
Washington D.C. District

?"Clothe yourselves, all of you, with humility toward one another, for God opposes the proud but gives grace to the humble." 1 Peter 5:5


Re: PC Control via Crestron

 


On Fri, Jan 13, 2017 at 8:12 PM, R M rojabuma@... [Crestron] <Crestron@...> wrote:

> The PC has a Serial port, but no API.
> Is there software I can load to get the PC to talk to the PRO3 via serial?
>
> Also, Is there a keyboard/mouse emulator to act like a TCP/IP client?
>
> The Emulator would need to allow TCP packets to a port listener.
>
> Maybe a SIMPL module already exists to to this?

We've had good luck with using the Crestron RS232 to USB cable to get our CP3's to control presentations on our conference room PCs. If keyboard commands are known, that might work for you.

For direct RS232 comm port control of specific programs such as MediaMatrix, Extron Quantum Elite, etc, we've used the Digi One SP Ethernet to Serial converters, which might be more suited to your needs. Our CP3s would talk to it as an Ethernet device and would relay serial commands to our various audio and video control server programs.

We didn't really care for the Crestron TCP module so our SW programmer wrote his own.

Hope this helps,
Jeff


-------------------------------------
Jeff Klein, DMC- E
Audio Visual Project Manager
Dept of Defense
Washington D.C. District

?"Clothe yourselves, all of you, with humility toward one another, for God opposes the proud but gives grace to the humble." 1 Peter 5:5


Re: Move to Pyng?

 

Per

? ??Scheduled events are only days of the week and not a calendar.? Currently to do something like putting shades down the sun hit a room I create 2-3 events that split the year into 3 as using only sunset as a guide does not correct for the sun position so an area may get sun early vs sunset in the summer vs winter.?? I use this often so if there is a better way to solve this problem I would be interested to learn from others.?

I just recently talked about this on my blog and posted code on github that calculates the angle and elevation to the sun and then operates shades based on whether the sun is shining in the window or not. ? Windows are defined in an xml file that is read by the processor so the code knows the angle of the window for comparison with the sun angle to know when the sun is shining into the window or not.?

You can find the code here

?
And my blog here


Jay


------ Original Message ------
From: "bryn@... [Crestron]" <Crestron@...>
Sent: 1/14/2017 2:46:17 AM
Subject: [Crestron] Re: Move to Pyng?

?

Question for Chris or anybody that knows: Does Pyng consider every load on a panelized lighting system a "device", or just the modules? So in other words if you have 2 full panels with 8 full DIM8 modules would it be 16 devices, or 128 devices against the 250 limit?



---In Crestron@..., wrote :

All,?

?

Some notes on my PYNG first try.

?

I decided to jump into a Pyng system to try and upgrade my system¡­ 6 hours in and I feel I am about 50% done.?? There is a fair amount of ¡°devices¡± with 94 showing, which with a limit of 250 they should be able to get a lot bigger but either I am really slow (good possibility) or the system has some problems.?

?

¡¤???????? D3 vs Pyng everything is a scene, I realized very rarely do I have a load go on at 100% (typically 80%) or do I only want one load to go on with a button press. ?The scene creation is on another screen and would have to go to the area then go back to the button you wanted to press

¡¤???????? Doesn¡¯t support multi press / taps ¨C important where we want to do things where 1 tap does X and 2 taps does Y.? ?(Fan control is one use case)

¡¤???????? Status lights on switches act differently.? If you have a switch that top is on and bottom if off both lights maybe on

¡¤???????? Moving from D3 to Pyng is fairly hard if you use panel lighting.? All of the modules show up to learn into the system with the serial number which I have not have found a printout in the documentation options that actually shows the serial numbers.? If Crestron would add a PYNG documentation template to D3 I think it could have made this step a lot less painful.? Considering it is still necessary to design a panel in d3 to get the loads correctly and have documentation for the electrician I don¡¯t see how this would ever go away (unless studio does is)

¡¤???????? Adding key pads with panel lighting is just as painful as they show up with serial number but no documentation exists to print.? For both the modules and keypads I had D3 and Pyng open so I could step through the serial numbers and find them

¡¤???????? Scheduled events are only days of the week and not a calendar.? Currently to do something like putting shades down the sun hit a room I create 2-3 events that split the year into 3 as using only sunset as a guide does not correct for the sun position so an area may get sun early vs sunset in the summer vs winter.?? I use this often so if there is a better way to solve this problem I would be interested to learn from others.?

?

My overall thoughts are this would be ok for a customer that has never had experience with lighting control as it could be an easy way to get something in but I would not use it for panel lights and would limit to only a few dozen lighting loads.? I think the scene / load control needs to evolve before I would really want to use often.?? I was really interested in trying to get some of the other components integrated to see how it performed and get some experience with it before I sold it¡­but my environment maybe just too complex and I am going to try and get a friendly user to make a minimal investment to see how it works on a daily basis. L?

?

If I have missed some critical things in my integration that would have made this easier, please share your experiences as I could always try this again (when I have time again).

?

Thanks

?

Chris


Crestron Today issues

 

Hi all

Having some real issues with the "Crestron Today" notification view/watch widget.

I have an MC3 running 1.501.0105, and the paid SG (Silver) app running on a phone and an iPad.

In Simpl Windows, I've obviously got my "Crestron App Notification Widget Functions" extender added to my "Crestron App". For now, I have defined all 10 of my "item X pressed" joins, have an analog with a value of 10 going into "number of items" (this is set at boot) as well as 10 fields of text and the header going into the serial joins (again, set at boot)

For now the panel layout is loaded to the iPad and the iPhone locally and the full panel works perfectly. I have routed the joins to a test page and i can see the text and the value of the analogs has been set.


When i go to the notification view widget on the phone or ipad, or a watch paired with the phone, i just get "Not Configured" as the header, and on the watch, "Not Configured" along with 10 blank buttons.


I read about database version being newer than 70 - I am running:-


SIMPL Windows:? 4.05.04
SIMPL+? 4.04.01
Device Database: 81.00.002.00
Crestron Database:? 60.05.007.00
Crestron Toolbox: 2.42.541.00
SIMPL+ Cross Compiler: 1.3

Any ideas what I have missed?!



Cheers


Re: Move to Pyng?

 

Question for Chris or anybody that knows: Does Pyng consider every load on a panelized lighting system a "device", or just the modules? So in other words if you have 2 full panels with 8 full DIM8 modules would it be 16 devices, or 128 devices against the 250 limit?


---In Crestron@..., <chris.noland@...> wrote :

All,?

?

Some notes on my PYNG first try.

?

I decided to jump into a Pyng system to try and upgrade my system¡­ 6 hours in and I feel I am about 50% done.?? There is a fair amount of ¡°devices¡± with 94 showing, which with a limit of 250 they should be able to get a lot bigger but either I am really slow (good possibility) or the system has some problems.?

?

¡¤???????? D3 vs Pyng everything is a scene, I realized very rarely do I have a load go on at 100% (typically 80%) or do I only want one load to go on with a button press. ?The scene creation is on another screen and would have to go to the area then go back to the button you wanted to press

¡¤???????? Doesn¡¯t support multi press / taps ¨C important where we want to do things where 1 tap does X and 2 taps does Y.? ?(Fan control is one use case)

¡¤???????? Status lights on switches act differently.? If you have a switch that top is on and bottom if off both lights maybe on

¡¤???????? Moving from D3 to Pyng is fairly hard if you use panel lighting.? All of the modules show up to learn into the system with the serial number which I have not have found a printout in the documentation options that actually shows the serial numbers.? If Crestron would add a PYNG documentation template to D3 I think it could have made this step a lot less painful.? Considering it is still necessary to design a panel in d3 to get the loads correctly and have documentation for the electrician I don¡¯t see how this would ever go away (unless studio does is)

¡¤???????? Adding key pads with panel lighting is just as painful as they show up with serial number but no documentation exists to print.? For both the modules and keypads I had D3 and Pyng open so I could step through the serial numbers and find them

¡¤???????? Scheduled events are only days of the week and not a calendar.? Currently to do something like putting shades down the sun hit a room I create 2-3 events that split the year into 3 as using only sunset as a guide does not correct for the sun position so an area may get sun early vs sunset in the summer vs winter.?? I use this often so if there is a better way to solve this problem I would be interested to learn from others.?

?

My overall thoughts are this would be ok for a customer that has never had experience with lighting control as it could be an easy way to get something in but I would not use it for panel lights and would limit to only a few dozen lighting loads.? I think the scene / load control needs to evolve before I would really want to use often.?? I was really interested in trying to get some of the other components integrated to see how it performed and get some experience with it before I sold it¡­but my environment maybe just too complex and I am going to try and get a friendly user to make a minimal investment to see how it works on a daily basis. L?

?

If I have missed some critical things in my integration that would have made this easier, please share your experiences as I could always try this again (when I have time again).

?

Thanks

?

Chris


Re: Debugger digital signal indicators

 

Hi Heather,

It's better than it was and far more usable than the first update, though I'm still not used to it yet...? shame we just couldn't have an option to switch between the familiar and the "progressive"?;-)

Cheers,
Ol


Re: Pyng and setting set points from Simpl

 

Is there a way to have one of the whole house macros recall a setpoint and trigger that? Never used Pyng with HVAC.


PC Control via Crestron

R M
 

I am using a PRO3 processor and I need it to control a PC (Windows Embedded)

The PC has a Serial port, but no API.
Is there software I can load to get the PC to talk to the PRO3 via serial?

Also, Is there a keyboard/mouse emulator to act like a TCP/IP client?

The Emulator would need to allow TCP packets to a port listener.

Maybe a SIMPL module already exists to to this?

I appreciate your help!!


Pioneer VSX-924 HD zone IR hex codes

 

Hi all,


Does anyone happen to have IR hex codes for a Pioneer VSX 924 HD zone.


The Crestron modules have the main zone and zone two but no HD zone


Thanks

Kerry


Crestron & DSP Programmer Needed In Maryland, DC & VA Area

 

Hi group,?


I'm looking to hire a full time programmer in the Maryland, DC & VA area. Please respond to this post for more info or email.


Thanks,?


bizaudio@...


Re: Debugger digital signal indicators

Heather Baiman
 

¿ªÔÆÌåÓý

I'm still on Toolbox 2.42.324.

?

Have the Toolbox changes since this uproar about the colors resulted in a useable debugger?? I figure I'm going to be required to update Toolbox sometime soon.

?

Heather Baiman
Head of Programming
Electronic Environments
Office: 212-997-1110 Ext:125
Fax: 212-997-0474
heather@...
www.eeny.net

From: Crestron@... [mailto:Crestron@...]
Sent: Wednesday, October 12, 2016 8:29 PM
To: 'Crestron@...'
Subject: RE: [Crestron] Debugger digital signal indicators

?




A medium-sized crow has informed me that this should be in a higher-contrast form in the near future.

?

I like what they were going for in terms of consistency across the software (blue = digital across the board, etc) ¨C especially since one of the things I¡¯ve bitched about has been Crestron¡¯s lack of consistency ¨C but the change/lack of contrast in the arrows was not well conceived

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D

Commercial Market Director

Sr. Systems Architect | Crestron Certified Master Programmer (Gold)

Crestron Services Provider | Biamp Audia Certified | Extron Control Professional


From: Crestron@... [mailto:Crestron@...]
Sent: Wednesday, October 12, 2016 5:45 PM
To: Crestron@...
Subject: RE: [Crestron] Debugger digital signal indicators

?



No doubt! It's like someone there is trying to make it harder for us.

?





Re: RS-232 Digital Signage Control

 

Hey, does anyone happen to have example commands to change the text on one of these LED displays? ?Thanks.


Re: Apple TV 4 IP Control

 

Some good points Trey,


I personally would pay the 50 bucks in a heartbeat to have this working and not be using (because its not wasting) other's or my own time getting something to work just to not pay for it. As a one who supports both verbally and financially companies like Control Works, etc., I believe time and knowledge have value. ?Not just my own, but also that of my peers. ?This group is not only a great resource but also a good place to listen to & voice ideas that the rest of the world could care less about.

I guess I want it all...
some great sources to pay for what we don't have the either the time, imagination or experience to create, AND some like minded peeps to share ideas with without cost or obligation.

Glad you all are here!

Dan


Re: Alternative to Atlona?

 



Reliable and affordable.



2017-01-12 19:03 GMT-02:00 steve@... [Crestron] <Crestron@...>:

?

Anybody have a recommendation for a < DM video switching system with HDCP2.2/4K capabilities?? Atlona has been super unreliable for us over the last year.? Thanks!

Steve




--
Leandro Fernandes
Skype: Lefernandesrj
Tel.: (11) 94821-1114


Rotel RT-1570

 

Does anyone have the module for the Rotel RT-1570?



Re: Alternative to Atlona?

 

Not sure where you are based Steve, but check these out:

?



Great systems, the Alexa skill is pretty cool as well.
-slip