Keyboard Shortcuts
Likes
- Crestron
- Messages
Search
Re: Kramer VP-729
Jonathan Bannan
toggle quoted message
Show quoted text
On Sep 15, 2015, at 4:13 PM, 'B.O.' b.onnex@... [Crestron] <Crestron@...> wrote:
|
Re: Media Player application and CEN-NSP1 question?
Adonai Da Silva
Hi Lincoln, It's not even that, in my case i have shades controlling one area and shades controlling a different area, each panel show its own shade controls, also in one panel I have the Sonos 1 and 2 and the other panel i have iTunes and not Sonos. He didnt want to click on the audio button and see Sonos and iTunes in the Master and neither see the Living room shades showing up in the Master Bedroom panel.? I found it easier making two different ones. On Tuesday, September 15, 2015 1:36 PM, "Lincoln King-Cliby lincoln@... [Crestron]"
?
There are a number of ways ¨C putting things on subpages, controlling the subpage visibility based on which IPID the panel is communicating on, using the visibility/enable property of buttons, etc. depending on how much is different and what effect you¡¯re trying to communicate (e.g. is the function ¡°Disabled¡± on that particular message but there should still be some indication that it exists, or do you want the user to be completely unaware that a specific function is possible?) ? -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D Commercial Market Director Sr. Systems Architect | Crestron Certified Master Programmer (Gold) ControlWorks Consulting, LLC V: 440.449.1100 x1107 F: 440-449-1106 I: Crestron Services Provider | Biamp Audia Certified | Extron Authorized Programmer ? From: Crestron@... [mailto:Crestron@...] Sent: Tuesday, September 15, 2015 1:00 PM To: Crestron@... Subject: Re: [Crestron] Media Player application and CEN-NSP1 question? ? The reason I have crested one for each is that there are stuff in one panel that the client doesn't want to showing up in the other. Unless there is a way to do it and I haven't done it yet. ? ? On Tuesday, September 15, 2015 9:41 AM, "Heather Baiman heather@... [Crestron]" <Crestron@...> wrote: ? ? They would use the same smart object join.? But I question your decision to make 2 separate panel files for the same panel type?? It will be easier to maintain one panel file and just use logic to drive elements that are specific to zones. ? From: Crestron@... [mailto:Crestron@...] Sent: Tuesday, September 15, 2015 9:35 AM To: Crestron@... Subject: [Crestron] Media Player application and CEN-NSP1 question? ? Anyone out there that has used this application to use with CEN-NSP1? I have 2 V12 Panels one for the Master Bed and one for the Family Room. I have individual VTpro project for each and my question is. Since is only one CEN-NSP1 in the network, Do I use the same Smart Object Join for both of the projects or do they have to be different? I have already created a Subpage for each panel and inserted the the Media player application with Join 2 for both. ? ? Thank you ============================================================================ Please refer to for important disclosures regarding this electronic communication. ============================================================================ ? |
Problem with Nexia Dialer
Hi All, Having a strange problem with a Nexia Dialer module. The Feed Back for On Hook Off Hook function fine until you get in incoming call. Once you get an incoming call, if you answer it or decline it, the on hook feed back stays high all the time, the off hook feed back never goes high and the incoming call Feed Back stops working. Getting all sigs in debugger from the biamp. Any ideas? Thank You for your help |
Re: Kramer VP-729
¿ªÔÆÌåÓýYou can try this command:In1: Y 0 0 0\x0D In2: Y 0 0 1\x0D . . . HDMI1: Y 0 0 6\x0D HDMI2: Y 0 0 7\x0D Le 15/09/2015 20:45, Jon Bannan
bannan@... [Crestron] a ¨¦crit?:
? |
Re: How to add a password to access a page or subpage for the TSW-1052?
Adonai Da Silva
Have you done using the keyboard that is built into the TSW-752? On Tuesday, September 15, 2015 1:29 PM, "Lincoln King-Cliby lincoln@... [Crestron]" wrote:
?
You¡¯re going to need to do that in both VTP and SIMPL ¨C you can build the keypad however you want (using the keypad smart object, using a collection of discreet buttons, whatever) then use one of the password modules in SIMPL unless you feel like rolling your own logic to implement passwords/backdoors/checks/etc. ? Lincoln? ? -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D Commercial Market Director Sr. Systems Architect | Crestron Certified Master Programmer (Gold) ControlWorks Consulting, LLC V: 440.449.1100 x1107 F: 440-449-1106 I: Crestron Services Provider | Biamp Audia Certified | Extron Authorized Programmer ? From: Crestron@... [mailto:Crestron@...] Sent: Tuesday, September 15, 2015 1:06 PM To: Crestron@... Subject: [Crestron] How to add a password to access a page or subpage for the TSW-1052? ? Hi Guys, ? I need to add a password request to be able for someone to access the thermostat subpage in VTPro. Where would be the place to go in VTPro to set that up. Client wants to do this so the kids doesn't mess up with the thermostat in the panel. ? Thank you. |
Re: Kramer VP-729
Hello.
According to the documentation is on the website of Kramer, the commands to change source are: Select Input 1: Y 0 0 0\x0D Select Input 2: Y 0 0 1\x0D Select Input 3: Y 0 0 2\x0D Select Input 4: Y 0 0 3\x0D Select VGA1: Y 0 0 4\x0D Select VGA2: Y 0 0 5\x0D Select HDMI1: Y 0 0 6\x0D Select HDMI2: Y 0 0 7\x0D Select USB: Y 0 0 8\x0D Port config: 9600 8N1 |
Re: Windows 10 Upgrade
¿ªÔÆÌåÓýyep, just reboot. all will be okay again for a few more compiles¡
|
Re: Media Player application and CEN-NSP1 question?
¿ªÔÆÌåÓýThere are a number of ways ¨C putting things on subpages, controlling the subpage visibility based on which IPID the panel is communicating on, using the visibility/enable property of buttons, etc. depending on how much is different and what effect you¡¯re trying to communicate (e.g. is the function ¡°Disabled¡± on that particular message but there should still be some indication that it exists, or do you want the user to be completely unaware that a specific function is possible?) ? -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D Commercial Market Director Sr. Systems Architect | Crestron Certified Master Programmer (Gold) ControlWorks Consulting, LLC V: 440.449.1100 x1107 F: 440-449-1106 I: Crestron Services Provider | Biamp Audia Certified | Extron Authorized Programmer ? From: Crestron@... [mailto:Crestron@...]
Sent: Tuesday, September 15, 2015 1:00 PM To: Crestron@... Subject: Re: [Crestron] Media Player application and CEN-NSP1 question? ? The reason I have crested one for each is that there are stuff in one panel that the client doesn't want to showing up in the other. Unless there is a way to do it and I haven't done it yet. ? ? On Tuesday, September 15, 2015 9:41 AM, "Heather Baiman heather@... [Crestron]" <Crestron@...> wrote: ? ? They would use the same smart object join.? But I question your decision to make 2 separate panel files for the same panel type?? It will be easier to maintain one panel file and just use logic to drive elements that are specific to zones. ? From: Crestron@... [mailto:Crestron@...] ? Anyone out there that has used this application to use with CEN-NSP1? I have 2 V12 Panels one for the Master Bed and one for the Family Room. I have individual VTpro project for each and my question is. Since is only one CEN-NSP1 in the network, Do I use the same Smart Object Join for both of the projects or do they have to be different? I have already created a Subpage for each panel and inserted the the Media player application with Join 2 for both. ? ? Thank you ============================================================================ Please refer to for important disclosures regarding this electronic communication. ============================================================================ ? |
Re: How to add a password to access a page or subpage for the TSW-1052?
¿ªÔÆÌåÓýYou¡¯re going to need to do that in both VTP and SIMPL ¨C you can build the keypad however you want (using the keypad smart object, using a collection of discreet buttons, whatever) then use one of the password modules in SIMPL unless you feel like rolling your own logic to implement passwords/backdoors/checks/etc. ? Lincoln? ? -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D Commercial Market Director Sr. Systems Architect | Crestron Certified Master Programmer (Gold) ControlWorks Consulting, LLC V: 440.449.1100 x1107 F: 440-449-1106 I: Crestron Services Provider | Biamp Audia Certified | Extron Authorized Programmer ? From: Crestron@... [mailto:Crestron@...]
Sent: Tuesday, September 15, 2015 1:06 PM To: Crestron@... Subject: [Crestron] How to add a password to access a page or subpage for the TSW-1052? ? Hi Guys, ? I need to add a password request to be able for someone to access the thermostat subpage in VTPro. Where would be the place to go in VTPro to set that up. Client wants to do this so the kids doesn't mess up with the thermostat in the panel. ? Thank you. |
How to add a password to access a page or subpage for the TSW-1052?
Hi Guys, I need to add a password request to be able for someone to access the thermostat subpage in VTPro. Where would be the place to go in VTPro to set that up. Client wants to do this so the kids doesn't mess up with the thermostat in the panel. Thank you. |
Re: Media Player application and CEN-NSP1 question?
Adonai Da Silva
The reason I have crested one for each is that there are stuff in one panel that the client doesn't want to showing up in the other. Unless there is a way to do it and I haven't done it yet. On Tuesday, September 15, 2015 9:41 AM, "Heather Baiman heather@... [Crestron]" wrote:
?
They would use the same smart object join.? But I question your decision to make 2 separate panel files for the same panel type?? It will be easier to
maintain one panel file and just use logic to drive elements that are specific to zones.
? From: Crestron@... [mailto:Crestron@...]
Sent: Tuesday, September 15, 2015 9:35 AM To: Crestron@... Subject: [Crestron] Media Player application and CEN-NSP1 question? ?
Anyone out there that has used this application to use with CEN-NSP1?
I have 2 V12 Panels one for the Master Bed and one for the Family Room. I have individual VTpro project for each and my question is.
Since is only one CEN-NSP1 in the network, Do I use the same Smart Object Join for both of the projects or do they have to be different?
I have already created a Subpage for each panel and inserted the the Media player application with Join 2 for both.
?
?
Thank you
============================================================================ Please refer to http://www.eeny.net/disclaimer.txt for important disclosures regarding this electronic communication. ============================================================================ |
Re: Media Player application and CEN-NSP1 question?
Heather Baiman
¿ªÔÆÌåÓýThey would use the same smart object join.? But I question your decision to make 2 separate panel files for the same panel type?? It will be easier to maintain one panel file and just use logic to drive elements that are specific to zones. ? From: Crestron@... [mailto:Crestron@...]
Sent: Tuesday, September 15, 2015 9:35 AM To: Crestron@... Subject: [Crestron] Media Player application and CEN-NSP1 question? ?
Anyone out there that has used this application to use with CEN-NSP1? I have 2 V12 Panels one for the Master Bed and one for the Family Room. I have individual VTpro project for each and my question is. Since is only one CEN-NSP1 in the network, Do I use the same Smart Object Join for both of the projects or do they have to be different? I have already created a Subpage for each panel and inserted the the Media player application with Join 2 for both. ? ? Thank you
============================================================================ Please refer to http://www.eeny.net/disclaimer.txt for important disclosures regarding this electronic communication. ============================================================================ |
Media Player application and CEN-NSP1 question?
Anyone out there that has used this application to use with CEN-NSP1? I have 2 V12 Panels one for the Master Bed and one for the Family Room. I have individual VTpro project for each and my question is. Since is only one CEN-NSP1 in the network, Do I use the same Smart Object Join for both of the projects or do they have to be different? I have already created a Subpage for each panel and inserted the the Media player application with Join 2 for both. Thank you |