ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Re: Core 3.......ya

 

They added a parameter to adjust the "liquid" smoothing, aka lag. Dunno if
it's in release, may be a Labs-only thing right now.

On Fri, Mar 22, 2013 at 2:08 PM, Sean <seanzombie56@...> wrote:

Bouncy Scrolly, fantastic.....

I have the TSW directly connected to a CP3N. Oh well, I'm tweaking it to
the best of my ability.

Maybe fast analog feedback will be a Day 2 feature.


Thanks for the help

Sean

--- In Crestron@..., "jbudz1977" <jbudz1977@...> wrote:

The gauges have a little animation to them... Crestron calls it their
"Bouncy Scrolly," trying to make things more "Apple Like."

I would also try the same example on a dedicated network, a noisy
network can cause "hickups."

Jeff


--- In Crestron@..., "Sean" <seanzombie56@> wrote:

Anyone have issues displaying an analog gauge in core 3?

Specifically the analog feedback seems to update slowly. I tested
with just an analog ramp and two buttons to ramp up/down. The analog gauge
ramps up and down but slowly and keeps ramping visually after I release the
buttons.

Same program/ buttons/ analog ramp/ analog gauge - work fine and
update correctly on a standard panel / XPanel.


Sean



------------------------------------




Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the
Database area.
Yahoo!
Groups Links


--
Jeremy Weatherford


Re: Core 3.......ya

 

Bouncy Scrolly, fantastic.....

I have the TSW directly connected to a CP3N. Oh well, I'm tweaking it to the best of my ability.

Maybe fast analog feedback will be a Day 2 feature.


Thanks for the help

Sean

--- In Crestron@..., "jbudz1977" <jbudz1977@...> wrote:

The gauges have a little animation to them... Crestron calls it their "Bouncy Scrolly," trying to make things more "Apple Like."

I would also try the same example on a dedicated network, a noisy network can cause "hickups."

Jeff


--- In Crestron@..., "Sean" <seanzombie56@> wrote:

Anyone have issues displaying an analog gauge in core 3?

Specifically the analog feedback seems to update slowly. I tested with just an analog ramp and two buttons to ramp up/down. The analog gauge ramps up and down but slowly and keeps ramping visually after I release the buttons.

Same program/ buttons/ analog ramp/ analog gauge - work fine and update correctly on a standard panel / XPanel.


Sean


Re: Crestron Mobile Functions Device Extender

 

I guess it depends on your logic. How are you triggering the send?

I've only used it once a couple months ago, but as far as I know, it still works. Not hearing from customers is a good thing ;)

--- In Crestron@..., "innoventgroup" <innoventgroup@...> wrote:

thanks Ted. Another quick question, the function worked the first time but hasn't worked since. Anything I need to know that would have caused this? BTW, the APP is GPSDriveHD by motion.

thanks,
DAVE

--- In Crestron@..., "Ted" <ted_brincka@> wrote:

answer id 5282

--- In Crestron@..., "innoventgroup" <innoventgroup@> wrote:

Ok, I will bite, where in Crestron online help does it tell you what the url's are for the apps?

--- In Crestron@..., "Ted" <ted_brincka@> wrote:

How about duh, Crestron online help.

--- In Crestron@..., "innoventgroup" <innoventgroup@> wrote:

Please ignore this question... I figured it out... duh, Google :-)

--- In Crestron@..., "innoventgroup" <innoventgroup@> wrote:

Does anyone know how to figure out the URL for a APP on an iPad. I would like to use the Crestron Mobile Functions Device Extender to launch an APP for the client.

Thanks,
DAVE


Re: Crestron Mobile Functions Device Extender

innoventgroup
 

thanks Ted. Another quick question, the function worked the first time but hasn't worked since. Anything I need to know that would have caused this? BTW, the APP is GPSDriveHD by motion.

thanks,
DAVE

--- In Crestron@..., "Ted" <ted_brincka@...> wrote:

answer id 5282

--- In Crestron@..., "innoventgroup" <innoventgroup@> wrote:

Ok, I will bite, where in Crestron online help does it tell you what the url's are for the apps?

--- In Crestron@..., "Ted" <ted_brincka@> wrote:

How about duh, Crestron online help.

--- In Crestron@..., "innoventgroup" <innoventgroup@> wrote:

Please ignore this question... I figured it out... duh, Google :-)

--- In Crestron@..., "innoventgroup" <innoventgroup@> wrote:

Does anyone know how to figure out the URL for a APP on an iPad. I would like to use the Crestron Mobile Functions Device Extender to launch an APP for the client.

Thanks,
DAVE


Re: TSW series a lot to learn and ask...

Jesus @ Audio& Net Artist
 

I just spent couple of dead hours figuring out, between Core 3 Stuff and
the Greta Ipad example, getting the idea how can i merge both, but
I ended up just checking out and whatnot... My impression was: I do TPS as
Main Page and activities> A/V Distribution with a bar for sources on top
below status bar. follow by button bar with rooms and volume at side. so
selecting room then Source brings the sub page of that source and volume.

trying adapt this environmental to core 3 and new Ipad layout with the
rotation example That somehow i cannot see the rotation manager on my
definition of Mobile device on SIMPL.

I decided not to pay that much attention to example cause i dont then to
code that way and its just an example with bunch of "Main" Pages. but what
to do when you have 30 Light loads? put 4 loads per subpage and keep
fliping? I need to bang my head in this....
*Jesus Tossas*
*
*
*Technology Architect, Audio Engineer, Programmer*
*
*
*787-460-1223*
*
*
Contact Info <>


Crestron Mobile Pro G and MPEG4

 

Hello,

I've been trying for hours to integrate MPEG4 streaming into Crestron Mobile Pro G. Theorically, website says "Streaming MPEG video viewer" in the specs sheet.

I was unlucky to find any support either from Online Help and Crestron in Spain about it... they redirect me to the old mjpeg solution. I've been trying it with:
-Acti IP camera
-Aver IP camera
-VLC streaming

no lucky at all... meanwhile, TSW displays excellent H264/MPEG4 video quality (through rstp)

I'm not sure if Mobile Pro G can accept RSTP protocol, I've tried also a walkaround solution to stream H.264 through http not rstp but was not lucky either.


If someone could provide some light to this...

Kind regards,

Javier Mazón


DMCO-77

 

Hello guys,

I've recently found some information about a DMCO-77 future relase. It seems to be an DMCO with RSTP streaming capabilities. I'm wondering if there's any information about it somewhere..

I would be excited to integrate DM signals into TSW through RSTP h264.

Kind regards,

Javier Mazón


Re: Crestron Mobile Functions Device Extender

 

answer id 5282

--- In Crestron@..., "innoventgroup" <innoventgroup@...> wrote:

Ok, I will bite, where in Crestron online help does it tell you what the url's are for the apps?

--- In Crestron@..., "Ted" <ted_brincka@> wrote:

How about duh, Crestron online help.

--- In Crestron@..., "innoventgroup" <innoventgroup@> wrote:

Please ignore this question... I figured it out... duh, Google :-)

--- In Crestron@..., "innoventgroup" <innoventgroup@> wrote:

Does anyone know how to figure out the URL for a APP on an iPad. I would like to use the Crestron Mobile Functions Device Extender to launch an APP for the client.

Thanks,
DAVE


Re: Crestron Mobile Functions Device Extender

 

I'm fairly sure they have to be set and documented by the individual app developer, and not all support this integration.

--- In Crestron@..., "innoventgroup" <innoventgroup@...> wrote:

Ok, I will bite, where in Crestron online help does it tell you what the url's are for the apps?

--- In Crestron@..., "Ted" <ted_brincka@> wrote:

How about duh, Crestron online help.

--- In Crestron@..., "innoventgroup" <innoventgroup@> wrote:

Please ignore this question... I figured it out... duh, Google :-)

--- In Crestron@..., "innoventgroup" <innoventgroup@> wrote:

Does anyone know how to figure out the URL for a APP on an iPad. I would like to use the Crestron Mobile Functions Device Extender to launch an APP for the client.

Thanks,
DAVE


Re: Crestron Mobile Functions Device Extender

innoventgroup
 

Ok, I will bite, where in Crestron online help does it tell you what the url's are for the apps?

--- In Crestron@..., "Ted" <ted_brincka@...> wrote:

How about duh, Crestron online help.

--- In Crestron@..., "innoventgroup" <innoventgroup@> wrote:

Please ignore this question... I figured it out... duh, Google :-)

--- In Crestron@..., "innoventgroup" <innoventgroup@> wrote:

Does anyone know how to figure out the URL for a APP on an iPad. I would like to use the Crestron Mobile Functions Device Extender to launch an APP for the client.

Thanks,
DAVE


Just Got My DMC-E Today!

ewilliams0305
 


Re: TSW series a lot to learn and ask...

Heath Volmer
 

On Mar 22, 2013, at 8:53 AM, jbudz1977 <jbudz1977@...> wrote:

My advise with Core 3 would be to start from the groud up, instead of trying to use a complicated example to learn from.
+1


Don't try to get wrapped up in making a Core 3 panel look exactly like an existing GUI that was done for a synapse panel, I think that is where a lot of people got hung up in the beginning.
+ 50. Guilty as charged. If you can, wait for the stuff in Labs to make it out. It will be much easier to use your existing images.


Re: Crestron Mobile Functions Device Extender

 

How about duh, Crestron online help.

--- In Crestron@..., "innoventgroup" <innoventgroup@...> wrote:

Please ignore this question... I figured it out... duh, Google :-)

--- In Crestron@..., "innoventgroup" <innoventgroup@> wrote:

Does anyone know how to figure out the URL for a APP on an iPad. I would like to use the Crestron Mobile Functions Device Extender to launch an APP for the client.

Thanks,
DAVE


Re: Crestron Mobile Functions Device Extender

Georges Khalil
 

I will hijack your question (if you don't mind!) and would like to know if
that also works for the Android application? Has anyone tried it before? It
would be nice to be able to launch for example the Sonos application frmo
within the Crestron Mobile app.


--
Georges Khalil, M.Sc.A.

Directeur de l'ingnierie
Engineering Manager

Design Homesync Inc.
www.homesync.ca
T : 514 360-3414


On Fri, Mar 22, 2013 at 11:55 AM, innoventgroup <innoventgroup@...>wrote:

**


Please ignore this question... I figured it out... duh, Google :-)


--- In Crestron@..., "innoventgroup" <innoventgroup@...>
wrote:

Does anyone know how to figure out the URL for a APP on an iPad. I would
like to use the Crestron Mobile Functions Device Extender to launch an APP
for the client.

Thanks,
DAVE


[Non-text portions of this message have been removed]


Re: Crestron Mobile Functions Device Extender

innoventgroup
 

Please ignore this question... I figured it out... duh, Google :-)

--- In Crestron@..., "innoventgroup" <innoventgroup@...> wrote:

Does anyone know how to figure out the URL for a APP on an iPad. I would like to use the Crestron Mobile Functions Device Extender to launch an APP for the client.

Thanks,
DAVE


Re: Tandberg Buffer Overflow error

 

I'm assuming the log entries you've included are from the Simpl+ module
'Tandberg MXP Processor v1 (cm)'.



Adding a ClearBuffer is rarely a good solution to a buffer overflow. I'd
suggest one of two things:



Make the buffer bigger. This isn't anything like a sure-fire solution, but
it's easily accomplished. This really only works when a module that will
always, eventually process (and remove) all data from its buffer is
overwhelmed with a lot of data in a very short period of time.



Make sure the module is configured in such a way that all data will always
be processed (and removed) from the buffer, regardless of the timing of its
arrival.



The Simpl+ in question appears to be written in such a way that the contents
of the buffer, assuming all data is delimited with a New Line, will
eventually be processed regardless of timing. I'm not a big fan of the
specific method used* but in and of itself, it should function as intended.
My guess, is this is one of those somewhat rare instances where making the
buffer bigger might actually pay off.



*More than a few bits of the logic inside the TandbergRx$ Change could be
rewritten to make life easier for both the programmer and the processor, but
you'd have to give up X-Gen compatibility along the way.



From: Crestron@... [mailto:Crestron@...] On Behalf
Of coolaiddrinker
Sent: Friday, March 22, 2013 10:53 AM
To: Crestron@...
Subject: [Crestron] Tandberg Buffer Overflow error





Hi Guys,

I am starting to get buffer overflow issues from Tandberg MXP Full Control
module (crestron written). I opened the module to see where the issue is
indicated, I can see they have put remove command so technically the buffer
shouldn't overflow. Should I just put a clearbuffer command at the end of
change event to rid me of this issue.

here is what i am receiving in the error logs

ystem log:

1. Notice: CIP device 12: back ONLINE
TimeStamp: 20:23:56 3-20-13 UpTime: 0 days 00:01:08.15 Task: UDP_Serv
2. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1007, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.36 Task: EvD0004
3. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1021, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.39 Task: EvD0004
4. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1022, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.41 Task: EvD0004
5. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1011, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.43 Task: EvD0004
6. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1002, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.44 Task: EvD0004
7. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1013, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.46 Task: EvD0004
8. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1002, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.48 Task: EvD0004
9. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1024, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.58 Task: EvD0004
Total Errors Logged = 9

just for curiosity, how do you guys fix these issues as i experience them
with clearone/Biamp(sometimes) modules and some others(all crestron modules)
as well?

Thanks in advance.


Re: Tandberg Buffer Overflow error

Seth Olle
 

Believe there are console commands to do that.
Of note, in theory should not see this on a 3 series processor, as its memory allocation is much better. IN THEORY

From: coolaiddrinker <coolaiddrinker@...<mailto:coolaiddrinker@...>>
Reply-To: "Crestron@...<mailto:Crestron@...>" <Crestron@...<mailto:Crestron@...>>
Date: Friday, March 22, 2013 11:40 AM
To: "Crestron@...<mailto:Crestron@...>" <Crestron@...<mailto:Crestron@...>>
Subject: [Crestron] Re: Tandberg Buffer Overflow error



It does work fine but i wanted to not have error logs bogging the processor down.
Is there a way to clear those errors in the processor at the end of the day or something?

--- In Crestron@...<mailto:Crestron%40yahoogroups.com>, Seth Olle <seth@...> wrote:

IN reality, this is a physical issue with how the 2 series processors divide up memory.
In my experience no matter how big you make the buffers you will have the same problems.
It does seem to work fine even with the errors.

I went round and round once with this module, trying to change the buffer size, did not fix the problem.
The messages that come back from the MXP are sometimes quite large.
It should work fine however.

From: Brian Gross <brian@...<mailto:brian@...>>
Reply-To: "Crestron@...<mailto:Crestron%40yahoogroups.com><mailto:Crestron@...<mailto:Crestron%40yahoogroups.com>Crestron@...<mailto:Crestron%40yahoogroups.com><mailto:Crestron@...<mailto:Crestron%40yahoogroups.com>>>
Date: Friday, March 22, 2013 11:14 AM
To: "Crestron@...<mailto:Crestron%40yahoogroups.com><mailto:Crestron@...<mailto:Crestron%40yahoogroups.com>Crestron@...<mailto:Crestron%40yahoogroups.com><mailto:Crestron@...<mailto:Crestron%40yahoogroups.com>>>
Subject: [Crestron] Re: Tandberg Buffer Overflow error



I am curious what people have to say about this as well. With the Tandberg module, I pretty much had to remove/comment out all the Crestron written feedback portion of the module, and just write my own code for the feedback I needed.

--- In Crestron@...<mailto:Crestron%40yahoogroups.com><mailto:Crestron%40yahoogroups.com>, "coolaiddrinker" <coolaiddrinker@> wrote:

Hi Guys,

I am starting to get buffer overflow issues from Tandberg MXP Full Control module (crestron written). I opened the module to see where the issue is indicated, I can see they have put remove command so technically the buffer shouldn't overflow. Should I just put a clearbuffer command at the end of change event to rid me of this issue.

here is what i am receiving in the error logs

ystem log:

1. Notice: CIP device 12: back ONLINE
TimeStamp: 20:23:56 3-20-13 UpTime: 0 days 00:01:08.15 Task: UDP_Serv
2. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1007, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.36 Task: EvD0004
3. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1021, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.39 Task: EvD0004
4. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1022, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.41 Task: EvD0004
5. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1011, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.43 Task: EvD0004
6. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1002, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.44 Task: EvD0004
7. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1013, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.46 Task: EvD0004
8. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1002, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.48 Task: EvD0004
9. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1024, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.58 Task: EvD0004
Total Errors Logged = 9


just for curiosity, how do you guys fix these issues as i experience them with clearone/Biamp(sometimes) modules and some others(all crestron modules) as well?

Thanks in advance.


Re: Tandberg Buffer Overflow error

 

It does work fine but i wanted to not have error logs bogging the processor down.
Is there a way to clear those errors in the processor at the end of the day or something?

--- In Crestron@..., Seth Olle <seth@...> wrote:

IN reality, this is a physical issue with how the 2 series processors divide up memory.
In my experience no matter how big you make the buffers you will have the same problems.
It does seem to work fine even with the errors.

I went round and round once with this module, trying to change the buffer size, did not fix the problem.
The messages that come back from the MXP are sometimes quite large.
It should work fine however.

From: Brian Gross <brian@...<mailto:brian@...>>
Reply-To: "Crestron@...<mailto:Crestron@...>" <Crestron@...<mailto:Crestron@...>>
Date: Friday, March 22, 2013 11:14 AM
To: "Crestron@...<mailto:Crestron@...>" <Crestron@...<mailto:Crestron@...>>
Subject: [Crestron] Re: Tandberg Buffer Overflow error



I am curious what people have to say about this as well. With the Tandberg module, I pretty much had to remove/comment out all the Crestron written feedback portion of the module, and just write my own code for the feedback I needed.

--- In Crestron@...<mailto:Crestron%40yahoogroups.com>, "coolaiddrinker" <coolaiddrinker@> wrote:

Hi Guys,

I am starting to get buffer overflow issues from Tandberg MXP Full Control module (crestron written). I opened the module to see where the issue is indicated, I can see they have put remove command so technically the buffer shouldn't overflow. Should I just put a clearbuffer command at the end of change event to rid me of this issue.

here is what i am receiving in the error logs

ystem log:

1. Notice: CIP device 12: back ONLINE
TimeStamp: 20:23:56 3-20-13 UpTime: 0 days 00:01:08.15 Task: UDP_Serv
2. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1007, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.36 Task: EvD0004
3. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1021, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.39 Task: EvD0004
4. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1022, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.41 Task: EvD0004
5. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1011, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.43 Task: EvD0004
6. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1002, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.44 Task: EvD0004
7. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1013, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.46 Task: EvD0004
8. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1002, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.48 Task: EvD0004
9. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1024, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.58 Task: EvD0004
Total Errors Logged = 9


just for curiosity, how do you guys fix these issues as i experience them with clearone/Biamp(sometimes) modules and some others(all crestron modules) as well?

Thanks in advance.


Re: Tandberg Buffer Overflow error

Seth Olle
 

IN reality, this is a physical issue with how the 2 series processors divide up memory.
In my experience no matter how big you make the buffers you will have the same problems.
It does seem to work fine even with the errors.

I went round and round once with this module, trying to change the buffer size, did not fix the problem.
The messages that come back from the MXP are sometimes quite large.
It should work fine however.

From: Brian Gross <brian@...<mailto:brian@...>>
Reply-To: "Crestron@...<mailto:Crestron@...>" <Crestron@...<mailto:Crestron@...>>
Date: Friday, March 22, 2013 11:14 AM
To: "Crestron@...<mailto:Crestron@...>" <Crestron@...<mailto:Crestron@...>>
Subject: [Crestron] Re: Tandberg Buffer Overflow error



I am curious what people have to say about this as well. With the Tandberg module, I pretty much had to remove/comment out all the Crestron written feedback portion of the module, and just write my own code for the feedback I needed.

--- In Crestron@...<mailto:Crestron%40yahoogroups.com>, "coolaiddrinker" <coolaiddrinker@...> wrote:

Hi Guys,

I am starting to get buffer overflow issues from Tandberg MXP Full Control module (crestron written). I opened the module to see where the issue is indicated, I can see they have put remove command so technically the buffer shouldn't overflow. Should I just put a clearbuffer command at the end of change event to rid me of this issue.

here is what i am receiving in the error logs

ystem log:

1. Notice: CIP device 12: back ONLINE
TimeStamp: 20:23:56 3-20-13 UpTime: 0 days 00:01:08.15 Task: UDP_Serv
2. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1007, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.36 Task: EvD0004
3. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1021, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.39 Task: EvD0004
4. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1022, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.41 Task: EvD0004
5. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1011, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.43 Task: EvD0004
6. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1002, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.44 Task: EvD0004
7. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1013, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.46 Task: EvD0004
8. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1002, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.48 Task: EvD0004
9. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New = 1024, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.58 Task: EvD0004
Total Errors Logged = 9


just for curiosity, how do you guys fix these issues as i experience them with clearone/Biamp(sometimes) modules and some others(all crestron modules) as well?

Thanks in advance.


Crestron Mobile Functions Device Extender

innoventgroup
 

Does anyone know how to figure out the URL for a APP on an iPad. I would like to use the Crestron Mobile Functions Device Extender to launch an APP for the client.

Thanks,
DAVE