You may find that this question and any other module related questions can
be answered by opening an instance of SIMPL, set it up as a module then click on the ArgumentDefinition in program view then hit F1. This will get you a help page that explains how to set the parameter properties (close to bottom of page) inside a module and many other useful pieces of information on how to set up a module. HTH ChipG From: Crestron@... [mailto:Crestron@...] On Behalf Of avsystemdesign Sent: Sunday, February 20, 2011 10:56 AM To: Crestron@... Subject: [Crestron] Simpl module I want to create a module in Simpl, which contains an analog initialize feeding into an analog equate. I want the module to have a parameter field, so that I can for example in parameter field 1, enter 1d, this then needs to feed both the initialize and equate that value. A neat thing to have, but not necessary, would be to have its value set to a default of 1d for field 1, 2d for field 2 etc. Is this possible to do in Simpl or do I need to enter the world of S+ for this? Any help appreciated. _____ No virus found in this message. Checked by AVG - www.avg.com Version: 10.0.1204 / Virus Database: 1435/3454 - Release Date: 02/19/11 |
Re: NewOld.csp error in complie log
slip.cougan
Ahh, there lies the rub. Having been following the posts recently re 3.01.22.00 I'm a bit loath to upgrade just yet. We are trying to maintain similar stable environments on all our machines so I may just downgrade the Crestron Database to 23.05.010.01.
toggle quoted message
Show quoted text
I only upgraded that to get the myCrestron DNS demo working. Thanks for the info Robert. Kind regards Gary --- In Crestron@..., Robert Parker <robertparkernc@...> wrote:
|
Simpl module
I want to create a module in Simpl, which contains an analog initialize feeding into an analog equate.
I want the module to have a parameter field, so that I can for example in parameter field 1, enter 1d, this then needs to feed both the initialize and equate that value. A neat thing to have, but not necessary, would be to have its value set to a default of 1d for field 1, 2d for field 2 etc. Is this possible to do in Simpl or do I need to enter the world of S+ for this? Any help appreciated. |
Re: Driveway sensors
cabledude1122
Thanks for that link. Yes two way traffic was an issue with Cartell and looks like Renoae has a solution for it. No work around.
toggle quoted message
Show quoted text
--- In Crestron@..., Chris Niles <chris.niles.crestron@...> wrote:
|
Re: 120volts to trig 347Volts solution
Square D has a 120v coil DPDT 30 Amp relay with device mounting box that I use on exterior in ground lighting to isolate the switch from the lighting. Around $85.00.
Ross On Feb 20, 2011, at 11:18 AM, "Raphael Thiffault" <rthiffault@...> wrote: No problem to control the switch, i will check for a relay who can do the jobs. I have use in the past a box who control the light because the load use exceed the maximum value of the clW switch. [Non-text portions of this message have been removed] |
Re: 120volts to trig 347Volts solution
Raphael Thiffault
No problem to control the switch, i will check for a relay who can do the jobs. I have use in the past a box who control the light because the load use exceed the maximum value of the clW switch.
toggle quoted message
Show quoted text
I know we caln do the trick with the green light solution but the light switch are already install except for the 347 line. Raphaël Thiffault Programmeur Intégrations Duocom Canada 10000, Boul. Cavendish St-Laurent, Qc H4M 2V1 Message envoyé avec mon Blackberry ----- Message d'origine -----
De : Heath Volmer [mailto:hvolmer@...] Envoyé : Sunday, February 20, 2011 12:10 PM À : Crestron@... <Crestron@...> Objet : Re: [Crestron] 120volts to trig 347Volts solution I would imagine you can use a 120V coil relay to to that (as long as the switched voltage rating is sufficient. Mount the relay in a J-Box near the dimmer. Are you able to power the 120V CLW properly? I didn't realize that Canada's power was that different from the US. Heath On Sun, Feb 20, 2011 at 8:46 AM, Raphael Thiffault <rthiffault@...>wrote:
-- Heath Volmer Digital Domain Systems Littleton, CO 303-517-9714 ------------------------------------ Check out the Files area for useful modules, documents, and drivers. A contact list of Crestron dealers and programmers can be found in the Database area. Yahoo! Groups Links |
Re: 120volts to trig 347Volts solution
Heath Volmer
I would imagine you can use a 120V coil relay to to that (as long as the
switched voltage rating is sufficient. Mount the relay in a J-Box near the dimmer. Are you able to power the 120V CLW properly? I didn't realize that Canada's power was that different from the US. Heath On Sun, Feb 20, 2011 at 8:46 AM, Raphael Thiffault <rthiffault@...>wrote:
-- Heath Volmer Digital Domain Systems Littleton, CO 303-517-9714 [Non-text portions of this message have been removed] |
Re: 120volts to trig 347Volts solution
Relay or contactor, either with a 120v coil.
Chris On 2/20/2011 9:46 AM, Raphael Thiffault wrote:
[Non-text portions of this message have been removed] |
Re: 120volts to trig 347Volts solution
What you require is called a three phase "contactor" with a 120 volt coil.
toggle quoted message
Show quoted text
I am assuming that 347 volts is three phase, I not familiar with your power system in Canada. the American company Square D mfg.'s then in the states, but it is a common item. Confirm that the 120 volt coil on the contactor is with in the amp rating of the Crestron switch. I'm sure it will be well within the limits. Dean Lips Electronics ----- Original Message -----
From: Raphael Thiffault Date: Sunday, February 20, 2011 10:47 am Subject: [Crestron] 120volts to trig 347Volts solution To: Crestron@... Any suggestion. [Non-text portions of this message have been removed] |
Re: NewOld.csp error in complie log
I just had the same problem. You need to update your SIMPL as well. I
updated both the Crestron DB and the Device DB but did not update SIMPL and got the exact same error. Updated SIMPL to 3.01.22.00 and problem solved. HTH Robert On Sun, Feb 20, 2011 at 8:15 AM, slip.cougan <slip.cougan@...>wrote:
[Non-text portions of this message have been removed] |
Re: BENQ W5000
Over on AVS, there was discussion that the W5000 was being rebadged as a
toggle quoted message
Show quoted text
Sim2 D60. Try that protocol, serial specs, pinout. Chris On 2/20/2011 12:17 AM, roomy4545 wrote:
|
Re: Driveway sensors
So did we, before we switched to Rena A&E. Cartell's box is larger, and
toggle quoted message
Show quoted text
you'd need to custom wire 2 of them (and call them to get the wiring diagram) in order to do directional logic. We've been much happier, and haven't had any failures whatsoever. We buy the AX2-4-2C. (10-35v AC/DC, 2 connector, fail safe). It just works. Directional Logic (Model AX2DL): The Model AX2DL's directional logic feature uses the Channel 1 and Channel 2 loops to determine the direction a vehicle is traveling. The loops must spaced such that the vehicle can span both loops. The expected installation is two loops, one after the other in the same lane, spaced anywhere from overlapping to 6 feet apart. When a vehicle travels from the CH 1 Loop and enters the CH 2 Loop, the CH 2 Relay and LED activate to indicate the AB direction. When a vehicle travels from the CH 2 Loop and enters the CH 1 Loop, the CH 1 Relay and LED activate to indicate the BA direction. Chris On 2/20/2011 8:04 AM, tombaldwin1122 wrote:
|
Re: Driveway sensors
tombaldwin1122
Try these guys - -
toggle quoted message
Show quoted text
I have used them before without any issues. There is extra set of relays, either NO or NC where you can program an event after vehicle detection. Tom --- In Crestron@..., Heath Volmer <hvolmer@...> wrote:
|
Re: Squeezebox Module
fun_hackers
Hi,
toggle quoted message
Show quoted text
I'm stiil a beginner in programming SIMPL I've found the module on google code. I compiled it with SMPL+ and can see the module in SIMPL windows I also paste the module under the logic and assigned the required parameters such as IP address, tcp port and some singnals The TCPIP_Connect input I triggered with entering the Squeezepage on Touchpanel. But if i pressed for example the play button nothing happens on Squeezebox If I need a TCPIP Client to configure, how must I make the connection between the client and the module ? I can see in the debugger, that my button press goes out, but no tcpip communication seen --- In Crestron@..., Jason Melvin <jwmelvin@...> wrote:
|
Re: Squeezebox Module
fun_hackers
Hi,
toggle quoted message
Show quoted text
I'm stiil a beginner in programming SIMPL I've found the module on google code. I compiled it with SMPL+ and can see the module in SIMPL windows I also paste the module under the logic and assigned the required parameters such as IP address, tcp port and some singnals The TCPIP_Connect input I triggered with entering the Squeezepage on Touchpanel. But if i pressed for example the play button nothing happens on Squeezebox If I need a TCPIP Client to configure, how must I make the connection between the client and the module ? I can see in the debugger, that my button press goes out, but no tcpip communication seen --- In Crestron@..., Jason Melvin <jwmelvin@...> wrote:
|
NewOld.csp error in complie log
slip.cougan
I've just been handed an archive from one of my colleagues to make some additions. First thing I did was import the archive into simpl & compiled before making any changes (a habit I have to make sure there are not going to be issues before I make any changes)
My colleagues version compiles fine. I'm getting the errors listed below in the compile log: We are both running similar sw setups: SIMPL Windows: 2.12.44 SIMPL+: 3.03.13 symlib.tio: 690 iodev.tio: 690 Include3.dat 1.69 Device Database: 31.05.005.00 I'm running Crestron Database 24.00.039.00 whereas my colleague is running 23.05.010.01 (Can't see that that should make much difference) Compile log: ERROR (CMCVT149) File: C:\Documents and Settings\...\Simpl\NewOld.csp, Line 39 Undefined variable: '#IF_SERIES2' ERROR (CMCVT149) File: C:\Documents and Settings\...\Simpl\NewOld.csp, Line 41 Undefined variable: '#ELSE' ERROR (CMCVT149) File: C:\Documents and Settings\...\Simpl\NewOld.csp, Line 42 Undefined variable: 'GETPROGRAMNUMBER' ERROR (CMCVT149) File: C:\Documents and Settings\...\Simpl\NewOld.csp, Line 43 Unmatched symbol: '#ENDIF' ERROR (CMCVT149) File: C:\Documents and Settings\...\Simpl\NewOld.csp, Line 46 Statement outside of function scope ERROR (CMCVT149) File: C:\Documents and Settings\...\Simpl\NewOld.csp, Line 47 Missing ';' ERROR (CMCVT149) File: C:\Documents and Settings\...\Simpl\NewOld.csp, Line 48 Local variables must be declared at top of function ERROR (RLCMCVT171) Could not copy SIMPL+ output file to C:\Documents and Settings\...\Simpl\_S2_199_AV2__MAIN_PROCESSOR_20__feb_new.spl. WARNING(RLCMCVT220) NewOld.csh gets created in the \SPlsWork but I cannot find NewOld.csp so assume it gets deleted after the compile. Any ideas what may be causing these errors? Many thanks gary |
Re: MTX-3 Subpage Join Number Crash
I have had the same problem recently.
toggle quoted message
Show quoted text
Talk to True Blue, they have a firmware fix for it.... --- In Crestron@..., "Haydn Miller" <cresprog@...> wrote:
|
Re: Dm switcher not ready on power on
Thanks I will Try that it looks like it will do the trick