Re: Novastar TU15Pro and VX Series
toggle quoted message
Show quoted text
On Fri, 3 Jan 2025, 18:01 stevedearmore79 via , <stevedearmore79=[email protected]> wrote:
|
Re: Novastar TU15Pro and VX Series
Hi Steve, Please send to ady.putra@... Thank in advance On Fri, Jan 3, 2025, 22:01 stevedearmore79 via <stevedearmore79=[email protected]> wrote:
|
Re: 2n Crestron RAVA
I¡¯m not in front an a 2N so I can¡¯t remember the settings page this is in, I think it under general settings, but you need to enable this.?
?
End Group Calls at First Rejection ¨C enable the device to end all outgoing group calls if any of the called destinations rejects the call. |
Crestron Home Extension driver
Hi all,
?
I am trying to compile the sample 'ExtensionDriver' from the latest SDK resources, and after resolving all missing dependencies and outdated framework issues, it is building without any major problems.?
However, the PKG file is not generated due to this error during startup:? "Null Exception: Reference to a string is not set to an instance of a String."
?
I am stuck without any clue.?
|
New Series4 symbol in SIMPL
¿ªÔÆÌåÓýHi, I noticed a new device symbol for 4-series processors was introduced into SIMPL. When I load an older program, SIMPL asks me to replace with the new one. Is that a good idea? Did anybody experience any issues? ? Thanks, Thorsten |
Topics in Home Automation - New Article in Residential Tech Today
Most articles on smart home technology, including many I've written, focus on smart home technology for a suburban home.? My latest article, "How to Maximize Small Spaces With Smart Furnishings", looks at how smart home technology, including robotic furnishing, can optimize living in small spaces.? Beyond that, the information in the article is applicable in other living situations.? For example, creating a room that converts between a home office and guest bedroom.
You can find the article here: For those interested in earlier articles that I've written, you can find those here: For these interested in even earlier content that I wrote, you can find it all here though older content has formatting issues due to a transfer from blogspot to wordpress. Thanks |
Re: Novastar H series
Your email link wasn't complete so I couldn't send you the .pdf I have. This is the only info I see in the manual for input selection.
?
?
4.3.1 Switching Input Source of Layer
(2) Command to switch input source of layer Switch the input source of layer to CardNo: 55 aa 00 00 fe 00 00 00 00 00 01 00 Addr0 Addr1 Addr2 Addr3 03 00 CardNo 00 00 SUM_L SUM_H The command data is in hexadecimal format. The parameter descriptions are as follows. a. CardNo stands for the slot number (refer to Appendix 3). For example, CardNo of HDMI 2.0 is 0x00. b. SUM_L and SUM_H constitute the checksum of this command frame, which is the sum of the underlined data and 0x5555. The calculation formula is as below. SUM = 0x00 + 0x00 + 0xfe + 0x00 + 0x00 + 0x00 + 0x00 + 0x00 + 0x01 + 0x00 + Addr0 + Addr1 + Addr2 + Addr3 + 0x03 + 0x00 + CardNo + Priority + Source + 0x5555, SUM = SUM_H<<8 + SUM_L (SUM_L stands for the lower 8 bits of SUM, while SUM_H stands for the higher 8 bits of SUM). c. Addr: Addr stands for the layer parameter address (Addr = Addr3<<24 + Addr2<<16 + Addr1<<8 + Addr0). Different layers have different parameter addresses. The calculation formula for Addr is Addr = 0x13020012 + WindowNo * 0x30. For example, if you want to adjust the parameters of MAIN layer, then Addr = 0x13020012 + 0 * 0x30 = 0x13020012, that is, Addr0 = 0x12, Addr1 = 0x00, Addr2 = 0x02, Addr3 = 0x13. d. Addr: Addr stands for the layer parameter address (Addr = Addr3<<24 + Addr2<<16 + Addr1<<8 + Addr0). Different layers have different parameter addresses. The calculation formula for Addr is Addr = 0x13020012 + WindowNo * 0x30. For example, if you want to adjust the parameters of PIP1 layer, then Addr = 0x13020012 + 1 * 0x30 = 0x13020042 = Addr3<<24 + Addr2<<16 + Addr1<<8 + Addr0 = 0x13<<24 + 0x02<<16 + 0x00<<8 + 0x42, that is, Addr0 = 0x42, Addr1 = 0x00, Addr2 = 0x02, Addr3 = 0x13. e. Addr: Addr stands for the layer parameter address (Addr = Addr3<<24 + Addr2<<16 + Addr1<<8 + Addr0). Different layers have different parameter addresses. The calculation formula for Addr is Addr = 0x13020012 + WindowNo * 0x30. For example, if you want to adjust the parameters of PIP2 layer, then Addr = 0x13020012 + 2 * 0x30 = 0x13020072 = Addr3<<24 + Addr2<<16 + Addr1<<8 + Addr0 = 0x13<<24 + 0x02<<16 + 0x00<<8 + 0x72, that is, Addr0 = 0x72, Addr1 = 0x00, Addr2 = 0x02, Addr3 = 0x13. ?
(2) Response packet
If the response packet is in the following format, the layer parameters are set successfully. aa 55 00 00 00 fe 00 00 00 00 01 00 Addr0 Addr1 Addr2 Addr3 00 00 SUM_L SUM_H ¡°SUM_L¡± and ¡°SUM_H¡± constitute the checksum of this command frame, which is the sum of the underlined data and 0x5555. The calculation formula is as below. SUM = 0x00 + 0x00 + 0x00 + 0xfe + 0x00 + 0x00 + 0x00 + 0x00 + 0x01 + 0x00 + Addr0 + Addr1 + Addr2 + Addr3 + 0x00 + 0x00 + 0x5555, SUM = SUM_H<<8 + SUM_L (SUM_L stands for the lower 8 bits of SUM, while SUM_H stands for the higher 8 bits of SUM). |
Re: Novastar H series
4.4.1 Loading Presets
(1) Command to load a preset Load Preset XX: 55 aa 00 00 fe 00 00 00 00 00 01 00 00 01 51 13 01 00 XX SUM_L SUM_H The command data is in hexadecimal format and XX stands for the preset number. The number range is 0x00-0x09 which represent Preset 1-10. For the detailed preset numbers, see Appendix 6. ¡°SUM_L¡± and ¡°SUM_H¡± constitute the checksum of this command frame, which is the sum of the underlined data and 0x5555. The calculation formula is as below. SUM = 0x00 + 0x00 + 0xfe + 0x00 + 0x00 + 0x00 + 0x00 + 0x00 + 0x01 + 0x00 + 0x00 + 0x01 + 0x51 + 0x13 + 0x01 + 0x00 + XX + 0x5555, SUM = SUM_H<<8 + SUM_L (SUM_L stands for the lower 8 bits of SUM, while SUM_H stands for the higher 8 bits of SUM). (2) Response packet If the response packet is in the following format, the preset is successfully loaded. aa 55 00 00 00 fe 00 00 00 00 01 00 00 01 51 13 00 00 b9 56 |
Re: Novastar H series
Hello Tonny,
Thanks but I need Hexa code for SIMPL windows or if you have module plss share at pasibalkrishan51@...
?
Thanks in advance? |
Re: JVC NZ9 Control
¿ªÔÆÌåÓýHo Oliver, ? Happy New Year (to the whole group) and any news on this topic? ? Thanks, Thorsten ? Von: [email protected] <[email protected]> Im Auftrag von Oliver Hall ? Hi Thorsten, I¡¯ll need to check the docs as the driver does support various aspect ratios and user preset recalls (for display mode configs) I¡¯ll report back¡ Oliver |
I'm guessing you are connecting to the Marantz and staying connected. For some reason if you are connected to the Marantz when Crestron reboots, Crestron can not reestablish the connection until the state of the Marantz changes. I'm guessing at this point is when the Marantz realizes the connection is no longer active and closes it.
What I have done in the past is, just after program start I send the http commands to power it on and then back off. It also helps a lot if you only have the Marantz connection connected when it is in use. |