Just wanted to give this one a quick bump as we had to deal with these this week.? We ran into a bug during install on the module v1.1 which displayed this error sporadically when changing setpoints:

[ The setpoint requested violate the deadband set by the user. ]

Contacted the module creators (ControlConcepts) and Jen was quick to send us the hotfix clz file to correct it and all appears to working properly now.? She mentioned they will be updating the app market module, but until that point, I would reach out to them to get the hotfix if you run into this issue.? Thanks again Jen!


Re: EcoBee Thermostat

 

On Mon, Aug 7, 2023 at 11:42 AM, XSDS wrote:
Anything with tokens and updating is always a PITA these days.
You can say that again!...


Re: EcoBee Thermostat

 
Edited

On Sat, Aug 5, 2023 at 11:48 AM, ckangis wrote:
On Fri, Aug 4, 2023 at 10:47 AM, Pat Molettieri wrote:
Intersystems Control in Canada has a Simpl module.?
I'll give them a plug also. Great guys who provide good support for their modules...
Thirded.? They have provided great support for all their modules.? There is a little front end work you need to do to get this particular module working tip top, but the back end of the module works great.? Anything with tokens and updating is always a PITA these days.


Re: Elk M1G security panel with C1M1 module. Feedback but no control

 

Not sure why they don't work simultaneously but I'm suspecting it has to do with the C1M1 occupying the serial port. We were even on the phone with Elk tech support and it was never mentioned as something that might cause an issue. The security guys were giving up and disconnecting when all of a sudden things started working. I did the ol' "wait.... what'd you? just do???"?


Re: Elk M1G security panel with C1M1 module. Feedback but no control

 

On Mon, Aug 7, 2023 at 08:57 AM, @johnmax wrote:
How could they not make them both work at the same time...
That's a rhetorical question, right?...:)


Re: Elk M1G security panel with C1M1 module. Feedback but no control

 

That got me too as we are new to Elk and evaluating the product. How could they not make them both work at the same time...


Re: EcoBee Thermostat

 

On Fri, Aug 4, 2023 at 10:47 AM, Pat Molettieri wrote:
Intersystems Control in Canada has a Simpl module.?
I'll give them a plug also. Great guys who provide good support for their modules...


Re: Send myself a text when....

 

¿ªÔÆÌåÓý

I would also throw out that I believe there are other advantages to using a notification service, like PushOver.? Living in the west, we use the Do Not Disturb setting on our phones to keep from being woken up by group texts from friends on the east coast who don't think about the fact that someone on the list is several time zones away when they send an early morning text.?? PushOver, and some of the other notification services, allow you to prioritize the notifications your processor sends with different priorities.? So, some can have a low priority that obeys the do not disturb setting but others can have a high priority that includes a sound even in the middle of the night.?

Finally, PushOver and Vybit include the ability to use different sounds for different notifications.? My wife and I do a great deal of mountain biking during the summer.? I send out notifications through PushOver whenever our WeatherFlow Tempest weather station detects lightning.? These have a custom sound so we don't have to look at our phone while riding to know that there is a thunderstorm approaching and it is time to head home.?

Hope this helps

Jay


On 8/4/2023 10:18 PM, Randy S wrote:

The problem with using the email to text gateways from the cell phone providers is they have recently started putting all kinds of antispam filters on the gateways that block any sort of suspicious messages and you can't count on them working all the time. I'd been sending texts from my Crestron system for years through those email gateways but they just got too unreliable so I looked for another way. My alternative is to have an old Android phone on a $8/month account with US Cellular. Using an Android program called Automagic I can send a simple HTTP Get request from the Crestron system to that phone and it will trigger an event that sends me texts on the cellular network directly. This has been working well for a while, though it's a total cludge.

I would also send those same messages via email at the same time, but that got snarky as the email providers put up stronger measures to stop the spammers from using their SMTP networks. The Cestron emails don't seem to have all the authentication data that Comcast, Gmail and others want to see to accept and send emails. I set up a free Sendgrid SMTP account and that's been working well for a long time.


Re: Send myself a text when....

 

The problem with using the email to text gateways from the cell phone providers is they have recently started putting all kinds of antispam filters on the gateways that block any sort of suspicious messages and you can't count on them working all the time. I'd been sending texts from my Crestron system for years through those email gateways but they just got too unreliable so I looked for another way. My alternative is to have an old Android phone on a $8/month account with US Cellular. Using an Android program called Automagic I can send a simple HTTP Get request from the Crestron system to that phone and it will trigger an event that sends me texts on the cellular network directly. This has been working well for a while, though it's a total cludge.

I would also send those same messages via email at the same time, but that got snarky as the email providers put up stronger measures to stop the spammers from using their SMTP networks. The Cestron emails don't seem to have all the authentication data that Comcast, Gmail and others want to see to accept and send emails. I set up a free Sendgrid SMTP account and that's been working well for a long time.


Re: Elk M1G security panel with C1M1 module. Feedback but no control

 

They figured it out.... Apparently you can't use the security RP software AND Crestron control at the same time.


Elk M1G security panel with C1M1 module. Feedback but no control

 

I have an Elk M1G that I'm trying to control IP in SIMPL through a C1M1 module. I am getting all proper feedback and status updates but for some reason I can't arm/disarm. I'm working with the security contractor and they've set the G29-G42 sections to checked for keypad, zones and output changes. I don't know of any other setup or configuration that's required. Anybody have any advice or recommendations on what I might try?


Re: Clearone Converge PRO 2 - ProcBlock control

 

I figured it out. Just had to use the module for GainMute control and name appropriately. Default names of the demo program mixed me up.


Clearone Converge PRO 2 - ProcBlock control

 

I am using the Clearone ConvergePro2 v1.2 IP demo project to control a ClearOne Converge Pro2 128VT.

I have control of the unit but I am unclear on how to control the "ProcBloc" entities which were configured by the DSP contractor.?

Control of the MicLine in and Outs works fine. If anyone can point me in the right direction that would be helpful. Thanks.


Re: EcoBee Thermostat

 

¿ªÔÆÌåÓý

Thank you!!

?

From: [email protected] <[email protected]> On Behalf Of Pat Molettieri
Sent: Friday, August 4, 2023 8:48 AM
To: [email protected]
Subject: Re: [crestron] EcoBee Thermostat

?

Intersystems Control in Canada has a Simpl module.?

?

Pat M

?

Please consider donating to the 2023 Helping Hands 280 mile charity bike ride.?? 100% match on all donations through link above.

?

?

From: "[email protected]" <[email protected]> on behalf of Doug Greenhalgh <Doug1369@...>
Reply-To: "[email protected]" <[email protected]>
Date: Friday, August 4, 2023 at 10:45 AM
To: "[email protected]" <[email protected]>
Subject: [crestron] EcoBee Thermostat

?

Hi All, does anyone have a module for this? I have looked through the archives and noticed the c3-na reference, but it looks like there out of business? Website just errors out. I am happy to pay for a module.


Re: EcoBee Thermostat

 

¿ªÔÆÌåÓý

Intersystems Control in Canada has a Simpl module.?

?

Pat M

?

Please consider donating to the 2023 Helping Hands 280 mile charity bike ride.?? 100% match on all donations through link above.

?

?

From: "[email protected]" <[email protected]> on behalf of Doug Greenhalgh <Doug1369@...>
Reply-To: "[email protected]" <[email protected]>
Date: Friday, August 4, 2023 at 10:45 AM
To: "[email protected]" <[email protected]>
Subject: [crestron] EcoBee Thermostat

?

Hi All, does anyone have a module for this? I have looked through the archives and noticed the c3-na reference, but it looks like there out of business? Website just errors out. I am happy to pay for a module.


EcoBee Thermostat

 

Hi All, does anyone have a module for this? I have looked through the archives and noticed the c3-na reference, but it looks like there out of business? Website just errors out. I am happy to pay for a module.


Re: TSW SIP/Rava send DTMF

 

Awesome, Thanks Eric that worked.
Regards
s


APIs for Tripp Lite UPS APIs

 

Hello, has anyone seen API documentation for Tripp Lite UPS's.? Specifically, I am interested this PDU - PDUMV20NETLX.

Thank you
Bryan


Re: Biamp Tesira Modules Suite

 

thank you.? I completely forgot to check Biamp site.??


Re: Biamp Tesira Modules Suite

 

This can all be found on Biamp's support website.

Module 1.7 deep dive