I'm getting these in my error logs:
? 10. Error: RouterTransportProcess # 2023-01-25 13:02:03 # ProcessPortForwardResponse: PortForwardList Add Failed
? 11. Error: RouterTransportProcess # 2023-01-25 13:02:03 # ProcessPortForwardResponse: PortForwardList Add Failed
? 12. Error: RouterTransportProcess # 2023-01-25 13:03:05 # ProcessPortForwardResponse: PortForwardList Add Failed
? 13. Notice: SimplPlus[App01] # 2023-01-25 13:03:05 # iMXPATAdd FAILED (SET PORT ERROR: -1)
? 14. Error: SimplPlus[App01] # 2023-01-25 13:03:05 #? UDPServer: Unable to open port on the LAN side - Will work only on the CS side
? 15. Error: SimplPlus[App01] # 2023-01-25 13:03:05 # iMXPATRemove FAILED (PORT_FORWARD 2SERIES_REM ERROR: Entry Not Located)
? 16. Error: SimplPlus[App01] # 2023-01-25 13:03:05 #? UDPServer - Unable to remove port mapping for LAN side on device disconnect.
? 17. Error: SimplPlus[App01] # 2023-01-25 13:03:05 # iMXPATRemove FAILED (PORT_FORWARD 2SERIES_REM ERROR: Entry Not Located)
? 18. Error: SimplPlus[App01] # 2023-01-25 13:03:05 #? UDPServer - Unable to remove port mapping for LAN side on device disconnect.
? 19. Error: RouterTransportProcess # 2023-01-25 13:12:01 # ProcessPortForwardResponse: PortForwardList Add Failed
? 20. Error: RouterTransportProcess # 2023-01-25 13:12:01 # ProcessPortForwardResponse: PortForwardList Add Failed
? 21. Error: RouterTransportProcess # 2023-01-25 13:12:01 # ProcessPortForwardResponse: PortForwardList Add Failed
? 22. Error: RouterTransportProcess # 2023-01-25 13:12:01 # ProcessPortForwardResponse: PortForwardList Add Failed
? 23. Error: SimplPlus[App01] # 2023-01-25 13:13:03 # iMXPATRemove FAILED (PORT_FORWARD 2SERIES_REM ERROR: Entry Not Located)
? 24. Error: SimplPlus[App01] # 2023-01-25 13:13:03 #? UDPServer - Unable to remove port mapping for LAN side on device disconnect.
? 25. Error: SimplPlus[App01] # 2023-01-25 13:13:03 # iMXPATRemove FAILED (PORT_FORWARD 2SERIES_REM ERROR: Entry Not Located)
? 26. Error: SimplPlus[App01] # 2023-01-25 13:13:03 #? UDPServer - Unable to remove port mapping for LAN side on device disconnect.
? 27. Error: SimplPlus[App01] # 2023-01-25 13:13:03 # iMXPATRemove FAILED (PORT_FORWARD 2SERIES_REM ERROR: Entry Not Located)
? 28. Error: SimplPlus[App01] # 2023-01-25 13:13:03 #? UDPServer - Unable to remove port mapping for LAN side on device disconnect.
? 29. Error: SimplPlus[App01] # 2023-01-25 13:13:03 # iMXPATRemove FAILED (PORT_FORWARD 2SERIES_REM ERROR: Entry Not Located)
? 30. Error: SimplPlus[App01] # 2023-01-25 13:13:03 #? UDPServer - Unable to remove port mapping for LAN side on device disconnect.
? 31. Error: RouterTransportProcess # 2023-01-25 13:15:03 # ProcessPortForwardResponse: PortForwardList Add Failed
? 32. Notice: SimplPlus[App01] # 2023-01-25 13:15:03 # iMXPATAdd FAILED (SET PORT ERROR: -1)
? 33. Error: SimplPlus[App01] # 2023-01-25 13:15:03 #? UDPServer: Unable to open port on the LAN side - Will work only on the CS side
? 34. Error: RouterTransportProcess # 2023-01-25 13:16:06 # ProcessPortForwardResponse: PortForwardList Add Failed
? 35. Notice: SimplPlus[App01] # 2023-01-25 13:16:06 # iMXPATAdd FAILED (SET PORT ERROR: -1)
? 36. Error: SimplPlus[App01] # 2023-01-25 13:16:06 #? UDPServer: Unable to open port on the LAN side - Will work only on the CS side
? 37. Error: RouterTransportProcess # 2023-01-25 13:17:07 # ProcessPortForwardResponse: PortForwardList Add Failed
? 38. Notice: SimplPlus[App01] # 2023-01-25 13:17:07 # iMXPATAdd FAILED (SET PORT ERROR: -1)
? 39. Error: SimplPlus[App01] # 2023-01-25 13:17:07 #? UDPServer: Unable to open port on the LAN side - Will work only on the CS side


I do have a SIMPL+ module that uses a C# code which contains the UDPServer object.
There's about 20 of these modules in the SIMPL code. The UDPservers are opening to specific IP addresses not broadcast.
Should I be worried about these error log entries?




Re: Manifest.xml not found

 

Is the App set for local file?


Re: VC4 and CrestronGo

 

Do you mean to reset the 90-day trial?


Re: VC4 and CrestronGo

 

I'm using the free trail.? I've rebuilt it a few times already to reset it.?


Need help controlling old Somfy shades via IR

 

I've inherited a project that is controlling older Somfy shades via IR but the Somfy has low->high voltage controllers in electric junction boxes.? Each junction box houses 6 or 9 small low->high voltage controllers which are all daisy chained together via an RJ11 cable that then goes to a little box with the IR emitter stuck to it from the Crestron processor.

The current program controls the shades but I don't have the source code so it's a rewrite.? None of the Somfy IR codes I'm finding in the Crestron database or RemoteCentral work to move any of the shades.? I've tried the IR driver with just up/down/stop, the IR driver with 8 channels, and the IR driver with 24 channels.

Anybody remember dealing with this kind of setup and can provide some guidance or an IR driver that may work?

You can see a picture of one of the electric junction boxes here :


Thanks,
Dorel


Re: VC4 and CrestronGo

 

@dblpnt you saved the day!?

Under settings -> Authentication Management, I had to add the group name (in my case set as administrator) and that was it!

To be honest I tried this yesterday but at first it didn't work because I was entering the wrong group name, but after you mentioned it,? I decided to take a good second look at it and got it right! Thanks for nudging me in the right direction.

?


Re: sony control 232 via ADCP

 

¿ªÔÆÌåÓý

Hi,

?

are you sure the ADCP is activated and running on the projector? It is off by default.

?

Cheers,

Thorsten

?

Von: [email protected] <[email protected]> Im Auftrag von Tray Schaeffer
Gesendet: Mittwoch, 25. Januar 2023 16:42
An: [email protected]
Betreff: [crestron] sony control 232 via ADCP

?

I saw other threads here but cannot use IP for control. 232 is my only option.?
Projector model is Sony VPL-PHZ60 and?I set the comspec to 38400 E 8 1.?

When I send a command, I just get the reply:?
err_cmd
Which means the comspec and 232 wiring are good.?

As a test, I used the following:?
power "on"\r
power "off"\r
also tested without the quotes.

Any ideas of what I can do more to gain control of this device??

Thanks in advance.

?


Re: VC4 and CrestronGo

 

Besides hardening, have you added the user group of the user you are using for the iPad in the authentication management on VC-4?


Re: Zoom Rooms app on TSW-1060

 

Same issue on well over a dozen 1060 panels here- called TB in the morning and they had the same advice, which I had already tried before calling.? So far no joy.? I know there are console commands to change the firmware update and sonos specific update manifest URLs, does anyone know of a command to change the regular app update manifest URL?? I was able to find the Zoom 5.12 APK somewhere, I'd like to try "sideloading" that via a modified app update manifest file.??

It's hopefully just a terrible coincidence?this happens the same day they release this:?
While also the day after the announcement of a 15% price increase in the 70 series panels.??

-Marc

On Wed, Jan 25, 2023 at 2:51 PM David H via <drh_784=[email protected]> wrote:
I had a customer call me this morning to report that the TSW-1060 in one of their conference rooms was showing the Crestron logo and the message: Application could not be installed. Please ensure there is an internet connection.

TB said to do the following:?Change Application to Default via web UI. Panel will reboot, then change app back to Zoom.Panel will reboot again, then go back to the same screen.Give it some time to download v5.13.0, which was released last night, and then Zoom should launch normally

This did not work and I am back on hold with TB.

Anyone run into this issue? If so, did you figure out a solution?

Thanks,
David?



--
Marc Polansky
Programmer - DNR Laboratories LLC
76 Westbury Park Road - Suite 101E
Watertown, CT 06795 - 203-263-0003


Zoom Rooms app on TSW-1060

 

I had a customer call me this morning to report that the TSW-1060 in one of their conference rooms was showing the Crestron logo and the message: Application could not be installed. Please ensure there is an internet connection.

TB said to do the following:?Change Application to Default via web UI. Panel will reboot, then change app back to Zoom.Panel will reboot again, then go back to the same screen.Give it some time to download v5.13.0, which was released last night, and then Zoom should launch normally

This did not work and I am back on hold with TB.

Anyone run into this issue? If so, did you figure out a solution?

Thanks,
David?


Manifest.xml not found

 

?Hey all. I am loading my Crestron App (silver one) for android. Loading project into the processor. I get the error Manifest.xml not found not sure what i am missing been a while since i have done this


Re: sony control 232 via ADCP

 

I updated firmware through the web interface, downloaded firmware from the support page for the projector model.?


Re: sony control 232 via ADCP

 

I am using the DB9 port for control.?
I saw in the documentation where baud rate for the HDBaseT port is 9600


Re: VC4 and CrestronGo

 

Hi @thesaabdr

Thank you for answering. One thing you did not mention was if you have a "paid" or "free-trial" version of VC4? (I'm on a free-trial)

I am running in Bridged mode just like you (when using Virtualbox this seems to be the best way to make the VC-4 appear on the network as transparently as possible) and I have this on a laptop other than the one I typically use for programming (so I don't have to worry about port-forwarding between Host OS and Guest OS)

This still doesn't solve my issue, but at least is good to hear that you can confirm to have this working... I wonder if there is a difference between Rocky and Alma in this regard...It would be reassuring to hear if anybody has this working on an Alma Linux install.

The system is definitely hardened as per instructions, because I can use Simpl Debugger just fine.?

For now, I continue to scratch my head...

?


Re: sony control 232 via ADCP

 

Hi Tray,

are you using the RS232 port on the projector or RS232 via HDBT?
Sony uses different baud rate on HDBT, iirc 19200 N 8 1, but not 100% sure if N or E.

Best regards
Crestronfreak55


Re: sony control 232 via ADCP

 

Nick,?

Since I have not heard back from Sony yet, how does one update the firmware??
Do I have to get a file and put it on a USB stick??


Re: Need help with Watchdog

 

Thanks Andy.

The plogs contain more of the same. Errors before the watchdog log entries are JSON in nature that deal with the NTP clock servers.
NVRAMreboot came up empty.


Re: sony control 232 via ADCP

 

I was having some control issues before I updated Firmware on the projector...?


Re: sony control 232 via ADCP

 

Thanks Zac,?

Yes, I have even parity set and get plain text reply from the projector.?
So, I am confident in the wiring and comspec.?
Display just does not like the command format. As always, MFR documents are very poor.?

Also tried PJ link commands via 232 but they did not work either.?
Called into Sony support. They say I might get a call back in a day or two.?


Re: sony control 232 via ADCP

 

Sony PJs require even parity. Check that setting and? put a loopback to confirm that bytes looped back are exactly what you sent.