Re: Sony VPL-VW695ES projector with RS-232 control
¿ªÔÆÌåÓýHi, i?m currently having issues with a GTZ380 and IP control at a client?s residence. I was using the Sony VPL-VW1000 v1.0 successfully with the VW790 he had before, but with the new projector (exact same physical connection and switch port), connection seems to drop after some time and being unreliable in general. So I dropped the module and went for using ADCP commands ¨C that seems to have fixed the issue: IP control is stable for a couple of weeks now. ? Cheers, Thorsten ? Von: [email protected] <[email protected]> Im Auftrag von ckangis ? [Edited Message Follows] Hi All, |
Re: Sony VPL-VW695ES projector with RS-232 control
Second to that some switches have error threasholds crc wise and will disable a port, you could be triggering a storm control mechanism,? A stretch, something flaky, turn poe off on the port if its not needed On Sat, Dec 24, 2022 at 7:01 PM <gbnet.hifi@...> wrote:
|
Re: Sony VPL-VW695ES projector with RS-232 control
¿ªÔÆÌåÓýThat¡¯s a fair point. ?If the same setup elsewhere is not having the network up and down issues then I would be suspicious of the networking side of things. ? Either an issue with a switch or Ethernet cabling / termination for that run of cable.?
On 25 Dec 2022, at 9:25 am, bi0drain <naplesisnotmyhome@...> wrote:
|
Re: Sony VPL-VW695ES projector with RS-232 control
I meant from previous network experience the switch port link speed negotiation between 10/100/1000... nic flapping, hence the up down state.... basic switch troubleshooting but it needs to be checked.... most of the time its fine, some times it needs to be forced..? On Sat, Dec 24, 2022 at 4:58 PM ckangis <chris@...> wrote: gbnet, |
Re: Sony VPL-VW695ES projector with RS-232 control
gbnet,
Though I have had good experience with IP control of Sony products, I pivoted back to RS232 for many things, as IP was getting a lot of noise, specifically with Smart TVs and their crappy apps and updates that clients couldn't handle. it seemed easier/better to update FW, disconnect the IP and run good 'ol reliable RS232...? ?Generally a very good thing... Obviously we don't have the same 'Smart' issues with projectors, so maybe I'll need to go that way, which allows for domotz monitoring,,, bi0drain (love the handle BTW!) Not sure exactly what you're getting at. are you referring to the IP monitoring? even when I set the IP address to be reserved, we still saw issues with both IP and serial stability...? My real concern is why would I have serial issues with no IP attached (assuming that Support is right about dual connections...:(? ?) |
Re: Sony VPL-VW695ES projector with RS-232 control
Dare i ask if your flapping behavior happens autonegotiate synch wise something happening at the net level / forced link speed. Some sort of interference based flapping. On Sat, Dec 24, 2022 at 4:44 PM ckangis <chris@...> wrote: Hi All, |
Re: Sony VPL-VW695ES projector with RS-232 control
¿ªÔÆÌåÓýI haven¡¯t seen this on my projector ( a 550es which is the same as American 675es) but I use IP only.?
Just curious why you use both rs232 and IP. ? For me the IP control has been rock solid with this projector. ? I mean 100% uptime for 2 plus years sort of rock solid. ? I get Al the feedback that I need via ip?
Just wondering what advantage rs232 has ?
On 25 Dec 2022, at 8:44 am, ckangis <chris@...> wrote:
|
Sony VPL-VW695ES projector with RS-232 control
Hi All,
I have a site with this projector, controlled via RS-232 thru a DM-RMC-4KZ-100-C room box (50' from the rack). It's been installed for about a couple years... Though I do not remember having this issue initially, for the last year, we have had a condition where after ~1-3 weeks, it will stop responding to commands and also the RX/feedback stops. Sony support says that this is common when you have both RS-232 and IP connections simultaneously, which we did, though the IP connection was only for management and Domotz pinging...We noticed that Domotz would see a tremendous amount of network Up/Down states, and then often it would just go down and stay down... Though I think the issue with having IP and Serial connections being a problem is bogus for a professional product, we have disconnected the IP connection. Still we've seen the issue, and it requires a hard-boot to restore the serial communications... Anyone else see this kind of behavior??? I have another site with a 715 that we have not seen this issue with.... FYI, I'm using the Sony VPL-VW1000 v1.0 serial module TIA! |
Re: VC4 Room to Room Communication
#vc4
For people searching this topic in the future, also verify you don't have Secure Only for connections.? If this is on you can't even get slot to slot connections to work.? Was setting up a new VM thinking something got installed wrong when I noticed this setting.
|
Re: Crestron DM-DA4-4K-C
#crestron
ok, Thank you very much!!
It's been a long week and my brain is fried. Have a good Christmas |
Re: Crestron DM-DA4-4K-C
#crestron
Don't think you need to add it. Just add your rmc's under the Ethernet and then set your ip table on the rmc's. The DA just needs to be on the same vlan as your controller.
toggle quoted message
Show quoted text
Thanks, Ephrain On Dec 23, 2022, at 11:03 AM, metalmok via groups.io <metalmok@...> wrote: |
Crestron DM-DA4-4K-C
#crestron
Does anyone know how to add a DM-DA4-4K-C to a Simpl program? It doesn't show up in the "Select a new device" window when I try to add it to my program. Tru Blu Support is closed today December 23rd for Christmas but I'm still working. The only reason I need it in my program is for RS-232 display control through the 4 DM-RMC-4KZ-100-C that are connected to it.
|
File /SonyAVRWebAPILibrary.clz uploaded
#file-notice
Group Notification
The following files and folders have been uploaded to the Files area of the [email protected] group. By: ckangis <chris@...> Description: |
Re: Sony STR-ZA1100ES direct volume setting
Nope, sorry! The archive has the old CLZ. I just posted the new (updated for NewtonSoft) CLZ in the files section. Search for 'SonyAVRWebAPILibrary.clz'
Put it and the S+ usp and ush files in your S+ library folder... |
Re: HTTP Post Help with a TCP/IP Client CP3
¿ªÔÆÌåÓýI believe postman shows the http code you would send. Its a button on the right looks like <>.
You can also use notepad and putty to port 80 to send the same text.?
If you're building the string in Simpl or Simpl+ then \n is \r\n. If using C#, then you would need \r\n.
Your content looks like json so I'm not sure if the header Content-Type should be application/json
Daniel Portugal
Cell: 562.519.6972
Email: joyousdan@...
|
Re: Funky RS232 Simpl Bug
#simpl
So what's the magic incantation that is breaking it? On Thu, Dec 22, 2022 at 9:39 AM Sam <sam.orifici@...> wrote: Hey all, just curious if anyone's seen this before. |
Re: VC4 Room to Room Communication
#vc4
Okay thanks, yeah I have it up in running. I guess it's just my OCD that's making me feel weird with this ...as you say "inconsistently enough" ...my brain is screaming at me to use a VC-4 EISC Server haha.
|