Re: Mag322 (Infomir) STB?IR?code ?

 

I just uploaded an IR driver I used for a MAG322 a few years ago.

/g/crestron/files/INFOMIR_MAG-250.ir

?


OT magazine and newsletters

 
Edited

Hi folks.
I'd like to be more educated and updated into newest trends.
Which magazines and or newsletters you like most in the commercial side of AV automation field?
Thanks


Re: SW-VMK-WIN

 

Hi Thorsten,?

i remeber that there was a document from TrueBlue which lined out some settings/registry changes so that this would also run on more recent Windows versions, maybe you want to reach out to them.?

Regards,?


StreamDeck Integration

 

Hi All
has anyone done any work on integration with StreamDeck?
Specifically, having a way for a StreamDeck button press to trigger an event in Crestron/SMW...

TIA!


Re: SW-VMK-WIN

 

OK - thanks, Tony.
Strange i didn?t get it to work.
I?m using now MCE and it seems to do the trick. EventGhost can do even more, but it?s also more complex and would be overkill for this job.

Cheers,
Thorsten

-----Urspr¨¹ngliche Nachricht-----
Von: [email protected] <[email protected]> Im Auftrag von Tony Golden
Gesendet: Dienstag, 31. Mai 2022 23:42
An: [email protected]
Betreff: Re: [crestron] SW-VMK-WIN

FYI, I used VMK-WIN on a couple of projects last year, with PCs running Windows 10. Although it worked okay for the simple functions I needed, MCE Controller and EventGhost looked a lot more flexible.

--- On Tuesday, May 31, 2022 at 2:51 AM, Thorsten K?hler wrote:

Yeah, i think it?s similar to EventGhost which i?ve used in the past.
I was just thinking using the Crestron tool would be easier to
interface as there are already drivers in SIMPL, but if the tool isn?t
working, that?s not helping.

@Chris
I?m not familiar with MCE, but EventGhost ()
is bidirectional and can trigger events to the outside world.


--- On Monday, May 30, 2022 at 8:50 PM, Geoffrey Reynolds wrote:

MCE Controller works really well:



Pair it with a TCP Client symbol in your SIMPL program and you're
good to
go.
I've been using it for years without any issues.



--- On Mon, May 30, 2022 at 4:09 PM Thorsten K?hler wrote:

i need to control a Windows 10 PC from a Crestron touchpanel and
wanted to give the VMK-WIN a try. It installs fine and the
service is running, but it doesn?t seem to work correctly. For
instance the Crestron symbol that should appear in the system tray after reboot is missing.
Any ideas or is this tool just too old for Windows 10/11?


Re: Horizon HZ-KPCN and HZ-KPEX on PAC2 and how do your remove the buttons.

 

I used a group (about 25) of HZ-KPCNwith a PAC2M and works fine. I only used the cresnet model, not the infinet.?


to remove the buttons use a mini plane screwdriver, and on the long sides, there's a small entry to the screwdriver.


Re: SW-VMK-WIN

 

FYI, I used VMK-WIN on a couple of projects last year, with PCs running Windows 10. Although it worked okay for the simple functions I needed, MCE Controller and EventGhost looked a lot more flexible.

--- On Tuesday, May 31, 2022 at 2:51 AM, Thorsten K?hler wrote:

Yeah, i think it?s similar to EventGhost which i?ve used in the past.
I was just thinking using the Crestron tool would be easier to interface as
there are already drivers in SIMPL, but if the tool isn?t working, that?s not
helping.

@Chris
I?m not familiar with MCE, but EventGhost () is
bidirectional and can trigger events to the outside world.


--- On Monday, May 30, 2022 at 8:50 PM, Geoffrey Reynolds wrote:

MCE Controller works really well:



Pair it with a TCP Client symbol in your SIMPL program and you're good to
go.
I've been using it for years without any issues.



--- On Mon, May 30, 2022 at 4:09 PM Thorsten K?hler wrote:

i need to control a Windows 10 PC from a Crestron touchpanel and wanted
to give the VMK-WIN a try. It installs fine and the service is running,
but it doesn?t seem to work correctly. For instance the Crestron symbol
that should appear in the system tray after reboot is missing.
Any ideas or is this tool just too old for Windows 10/11?


Horizon HZ-KPCN and HZ-KPEX on PAC2 and how do your remove the buttons.

 

I have an old PAC2 system (programmed in SIMPL) that I am suppose to add a number HZ-KPCN and HZ-KP keypads along with a CEN-GWEXER.? SIMPL lets me add these devices to program but I am a little concern that there may be issues with using them on a Series 2.? Has anyone used these devices with a Series 2 processor and did they work okay?

Also, how do you get the buttons off to replace them with engrave buttons?? I removed the face plate and the sub face plate.? But I cannot get the buttons off -- afraid I might break them if I apply too much force.

Thanks,
Steve


Re: TCP Client Stopped working

 

hi Michael,
I think my situation is different than what you're dealing with...
I just had a TCP client stop communicating and would not keep trying to re-connect.
Since rebooting the processor, we haven't had any issues (??). It was suggested that I set up a routine that periodically tests the connection and toggle the 'CONNECT' input if things are down for X time.
I haven't gotten to this as I don't have regular connection to this site.?
I assume that if I changed to a websocket, this would also 'solve' the potential issues...

Alternatively, It'd be great for Crestron to fix this kind of thing - In 20+ years of using TCP clients I've not had this issue personally, so it is very unusual I think...


Re: TCP Client Stopped working

 

I'm curious what the results were to your testing. ?I'm having a somewhat similar issue with a HTTP GET that is used for polling. ?I've been running on CP3 with both 1.6 and 1.8 FW and had the same results. ?If you look at the NETSTAT command you see sockets ESTABLISHED, WAITING, etc. ?The start port seems to be around 48xxx and when the counter gets to about 59xxx there are no more ports. ?I would thing the garbage collector in the OS would recycle these ports but no love. ?Ive seen this happen with S+ direct connections and S# GET with identical results. ?The only fix seems to be rebooting the proc :( ?I'm doing the same stress testing on a PRO4 and the start port is around 12xxx so the testing is taking quite a bit longer.

any ideas?


Re: Converting AMX Module to Crestron Module

 

I think my module would deal specificallu with the Antex sirius XM unit and is RS232. I saw the words triplePlay, which is what they call that, so I don't think it would help...


Re: Converting AMX Module to Crestron Module

 

It is a TriplePlay Server that communicates to each TriplePlay Play3R-SP1 signage players. Uses JSON for all communication. Working on creating control via C# but just not adverse in C# yet.

I would look at any module to get me going in the right direction.


Re: Converting AMX Module to Crestron Module

 

Hi Brad,
I'm thinking that there's no easy way to convert. probably the best way is to have both open side by side and just copy/paste the concepts into SMW

If you're talking about the Antex SRX-3 Sirius TriplePlay unit, I may have an old module to at least get you started...LMK


Converting AMX Module to Crestron Module

 

Has anyone or is it not worth the headache to attempt to take AMX Netlinx Studio Code and convert to Crestron.

AMX already has a TriplePlay Server Module but not able to find a Crestron version anywhere.


Re: Replacement for multichannel amplifier

 

¿ªÔÆÌåÓý

Hi Angel,

?

the Dayton Audio i?m using is pretty simple ¨C no Crestron control involved.

I?m using the input sense functionality of the amplifier, so each zone independently powers up when music playback starts.

The amplifier can also be turned on using a 12V trigger, but that would fire up all zones which i don?t want to.

?

HTH

?

Cheers,

Thorsten

?

Von: [email protected] <[email protected]> Im Auftrag von Angel Marti
Gesendet: Dienstag, 31. Mai 2022 17:00
An: [email protected]
Betreff: Re: [crestron] Replacement for multichannel amplifier

?

Hello all,

Thorsten, how did you controll the Dayton Audio amp, just commands or with some module?

I'm just started a project using a Dayton Audio amplifier, but I haven't found any module for it yet. Would you share something I can use for make it work?


Thank you, Angel.


Re: Replacement for multichannel amplifier

 

Hello all,

Thorsten, how did you controll the Dayton Audio amp, just commands or with some module?

I'm just started a project using a Dayton Audio amplifier, but I haven't found any module for it yet. Would you share something I can use for make it work?


Thank you, Angel.


Mag322 (Infomir) STB?IR?code ?

 

Hi

Looking for some IR captures of remote of Infomir STB (more specifically MAG322) although it looks to be same remote for all models. I found out an IP protocol but it looks quite cumbersome to get simple commands control. Someone got experiences with these ? or IR capture of the remote ?

Thanks

³Õ¾±²Ô³¦¨¨²Ô


Re: S# Pro on RMC4 with a DM-XIO-DIR #rmc4

 

Are you familiar with Answer ID?1000315?? Even with less than 65 endpoints defined, I have still seen similar issues with overloading the processor - I would recommend trying the commands in that section to see if it improves things.


On Thu, May 26, 2022 at 11:45 AM Mark via <junkmailhangar=[email protected]> wrote:
I have a program that defines a director, four NVX units, adds them to the unit and then registers the lot. I receive very odd messaging in the error log and am not sure where to begin looking. Another odd behavior is attempting to stop the program takes a very long time. Has anyone seen this before:


? 408. Error: SimplSharpPro[App01] # 2022-05-26 10:14:39 # ?Unable to post message to queue for Device ID DC for parent Type DEVICE_PARENT_ETHERNET_TYPE: IP-ID-DC
? 409. Error: CIPCommandProcessor # 2022-05-26 10:14:39 # ?SendDataToSocket: Send failed with error code 10058
? 410. Error: SimplSharpPro[App01] # 2022-05-26 10:14:59 # ?Unable to post message to queue for Device ID DC for parent Type DEVICE_PARENT_ETHERNET_TYPE: IP-ID-DC
? 411. Notice: TLDM # 2022-05-26 10:15:08 # WriteUnixDomainSocket: len=32 pid=3524; Thread 3539; timeout 20000; SO_SNDBUF 4196000 (tick end 77374425: start 77352881: delta 21544) maxMsg 4196; sendto /dev/shm/rqueue/SEND_1_QUEUE/0008469 error Resource temporarily unavailable(11)
? 412. Error: TLDM # 2022-05-26 10:15:08 # SendMessageToQueue : Unable to send message to queue App1Queue. Error Code 0xb
? 413. Error: SimplSharpPro[App01] # 2022-05-26 10:15:19 # ?Unable to post message to queue for Device ID DC for parent Type DEVICE_PARENT_ETHERNET_TYPE: IP-ID-DC
? 414. Notice: TLDM # 2022-05-26 10:15:28 # WriteUnixDomainSocket: len=76 pid=3524; Thread 3539; timeout 20000; SO_SNDBUF 4196000 (tick end 77394909: start 77374425: delta 20484) maxMsg 4196; sendto /dev/shm/rqueue/SEND_1_QUEUE/0008469 error Resource temporarily unavailable(11)
? 415. Error: TLDM # 2022-05-26 10:15:28 # SendMessageToQueue : Unable to send message to queue App1Queue. Error Code 0xb
? 416. Error: SimplSharpPro[App01] # 2022-05-26 10:15:39 # ?Unable to post message to queue for Device ID DC for parent Type DEVICE_PARENT_ETHERNET_TYPE: IP-ID-DC
? 417. Error: SimplSharpPro[App01] # 2022-05-26 10:15:59 # ?Unable to post message to queue for Device ID DC for parent Type DEVICE_PARENT_ETHERNET_TYPE: IP-ID-DC
? 418. Error: CIPCommandProcessor # 2022-05-26 10:16:14 # ?SendDataToSocket: Send failed with error code 10058
? 419. Error: SimplSharpPro[App01] # 2022-05-26 10:16:19 # ?Unable to post message to queue for Device ID DC for parent Type DEVICE_PARENT_ETHERNET_TYPE: IP-ID-DC
?


Re: 70 series VTP default page when processor offline

 

To find the reserved join, instead of typing a join number into the property box in VTP, use the drop-down beside it and select the function you want.
--
Josh Winn
The LiquidPixel Group