Sending an email with a Crestron Processor
Hi, I'm trying to send an email notification with a Crestron processor but I'm having problems finding a non encrypted non SSL service(since Crestron doesn't support authentication), any help on which email service is working for this purpose would be greatly appreciated. |
Re: Control of Elan equipment with Crestron
¿ªÔÆÌåÓý
Dustin,
Thankyou very much for your response and help.
From the looks of it. I will have to strip out all the Elan equipment and replace it with Crestron except for the tuner.?
Best regards,
Nirav
? From: Crestron@... on behalf of dustinwenninger@... [Crestron]
Sent: 14 June 2019 05:51 To: Crestron@... Subject: [Crestron] Re: Control of Elan equipment with Crestron ?
?
DT22: has RS-232 protocol listed in the manual (yes you can use this). HC12: This is Elan's version of a processor (as fas I know, no you can't).
M86a: Only talks with Elan components over ViaNet (I know the S86a you can use).
C2: Only talks with Elan components of ViaNet (I don't think you can use this).
|
Re: V24R-Wall and DGE2
Thanks, All for your responses
Just an FYI if you're in my situation, I contacted Wall-Smart and they will make a custom retro flush kit for this at a pretty reasonable price. They will make a version or their 2220 kit with a custom/larger bezel that will allow me to use the 2220 in place of the V24R-WALL, filling the hole. If you need this solution, or any other flush-mount solutions for Crestron TouchPanels or Keypads, or iPADs, etc. Check them out. I have had good luck with them: |
Re: Control of Elan equipment with Crestron
DT22: has RS-232 protocol listed in the manual (yes you can use this).
HC12: This is Elan's version of a processor (as fas I know, no you can't). M86a: Only talks with Elan components over ViaNet (I know the S86a you can use). C2: Only talks with Elan components of ViaNet (I don't think you can use this). |
Control of Elan equipment with Crestron
HI All, I am currently negotiating with a prospective client who has an Elan control system and lutron lighting control system. The client is looking to upgrade his Elan system and I am proposing Crestron rating than upgrading to newer Elan products, However, there is some Elan equipment that the client would like to retain and was wondering if there are modules available for controlling these with Crestron. I could not find anything for these equipment on application market and crestron database in Simpl.?? The existing equipment is:
? Any assistance is most appreciated.? Best regards, Nirav |
Re: V24R-Wall and DGE2
We had a client go for a Planar 24" display with the DM-DGE-200-C as a replacement for a DGE2/V24 because the 2220 wasn¡¯t big enough -- but we weren't concerned about filling a hole (they're on adjustable arms) so I can't say how close a match it would be size wise -- though there is a lot less bezel on the Planar than the V24 but the combo works well.
toggle quoted message
Show quoted text
Unfortunately as far as the V24 goes there's not a way to retain the V24 and upgrade the DGE -- have another client with a number of V24/DGE2s where we were looking at upgrading the DGE for weight and space reasons but had no need to change the display; engineering confirmed however that that wasn't/couldn¡¯t be supported. Lincoln -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D Commercial Market Director Sr. Systems Architect | Crestron Certified Master Programmer (Platinum) ControlWorks Consulting, LLC | D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106 Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer -----Original Message-----
From: Crestron@... <Crestron@...> Sent: Thursday, June 13, 2019 4:06 PM To: Crestron@... Subject: RE: [Crestron] V24R-Wall and DGE2 You don't have to use the TSD-2220. The DGE-100 and DM-DGE-200-C should work with most modern touchscreen monitors, so it should be possible to find something that's close to the size of the existing opening. You'll just have to do some searching... --- On Wednesday, June 12, 2019 at 2:29 AM, Michael Restrepo wrote: ------------------------------------ Posted by: "Tony Golden" <mrgolden@...> ------------------------------------ Check out the Files area for useful modules, documents, and drivers. A contact list of Crestron dealers and programmers can be found in the Database area. ------------------------------------ Yahoo Groups Links |
Re: V24R-Wall and DGE2
You don't have to use the TSD-2220. The DGE-100 and DM-DGE-200-C should work with most modern touchscreen monitors, so it should be possible to find something that's close to the size of the existing opening. You'll just have to do some searching...
toggle quoted message
Show quoted text
--- On Wednesday, June 12, 2019 at 2:29 AM, Michael Restrepo wrote: |
Re: LG Display IP Control WOL
What is the port number which you are using for IP control of the LG displays?
I don't think I have that documented anywhere and I would like to go ahead and try it out to see if at least I can get the display into a full standby mode and then use WOL to revive the display. I haven't dug through the files section to see if we have a friendly posted module for IP control on there or not.? I do have a solid enough LG module right now that works great for RS232 control of LG displays. Totally bums me out that they failed so hard on this.? We have a consultant specified system with over 100 LG displays and a Crestron Connected requirement, so I am pressing kind of hard on LG about this issue as well as Crestron for what integrators can expect when Crestron claims a display is Crestron Connected Certified.? Because it seems that they need to pressure LG, or remove them from their list.? Likewise, LG needs to actually meet the requirements, or stop advertising that functionality. Their RS232 is so good (IMO) compared to some others.? I'm saddened they didn't put the same effort into their LAN control. |
Sendmail Sharp General SendMail error
Have a job the SendMail Sharp module has been in that has been working for months.? No changes at all.? Suddenly the mail notifications stop working and looking at the module it is reporting General SendMail errors. Not sure what would have happened to cause this.? Nothing was changed.? Anyone else experiencing issues? |
Re: V24R-Wall and DGE2
¿ªÔÆÌåÓýCustom get the trim or tile guy to fix itMichael Restrepo | Owner
Restrepo Innovations
411 Sette Drive, Suite N3
Paramus, NJ 07652
Office | 201.925.0059
Cell| 201.952.4624
Email |
mike@...
|
SIMPL# Pro and HD-MD-400-C-E "HDCP Support"
Hi All If so could you help me with some information on how this was done. .HdcpSupportedLevelFeedback.ToString() Property always returns (Unknown) as I am assuming this device does not support this as support is either Enable or Disabled and does not support 2x. However when I try to Enable/Disable the HDCP Support using the code below this does not set the "HDCP Support" on the device, but the PrintLine will return the correct current value if I change this via the devices webpage. In this code basicSwitcher is the place holder for the HdMd400CE. I currently have the switching and sync detection functioning correctly so the device is online and the other parts of this code are correct. if (globalHDCP != null && globalHDCP.Value) ? ? ? ? ? ? ? ? { ? ? ? ? ? ? ? ? ? ? foreach (HdMdNxMHdmiInput hdmiInput in (basicSwitcher as HdMdxxxCE).HdmiInputs) ? ? ? ? ? ? ? ? ? ? { ? ? ? ? ? ? ? ? ? ? ? ? hdmiInput.HdmiInputPort.HdcpSupportOn(); ? ? ? ConsoleServer.PrintLine("HDMD400CE Input {0} HDCP Support = {1}, On = {2}", hdmiInput.ToString(), hdmiInput.HdmiInputPort.HdcpSupportedLevelFeedback.ToString(), hdmiInput.HdmiInputPort.HdcpSupportOnFeedback.ToString()); ? ? ? ? ? ? ? ? ? ? } ? ? ? ? ? ? ? ? } ? ? ? ? ? ? ? ? else ? ? ? ? ? ? ? ? { ? ? ? ? ? ? ? ? ? ? foreach (HdMdNxMHdmiInput hdmiInput in (basicSwitcher as HdMdxxxCE).HdmiInputs) ? ? ? ? ? ? ? ? ? ? { ? ? ? ? ? ? ? ? ? ? ? ? hdmiInput.HdmiInputPort.HdcpSupportOff(); ConsoleServer.PrintLine("HDMD400CE Input {0} HDCP Support = {1}, On = {2}", hdmiInput.ToString(), hdmiInput.HdmiInputPort.HdcpSupportedLevelFeedback.ToString(), hdmiInput.HdmiInputPort.HdcpSupportOnFeedback.ToString()); ? ? ? ? ? ? ? ? ? ? } ? ? ? ? ? ? ? ? } I have tried casting the HDMIInput as different types but have not been able to find the correct way of setting this value. I have also tried using the .HdcpSupportedLevel property but this has no effect. As this is available from SIMPL I am hoping it is available in SIMPL# Pro. Can anyone doing SIMPL# Pro offer any advice. Thanks in advance for any help. |
Re: QM-RMC 12V Trigger Output
I am utilizing the Paradigm Link Player's 12V trigger to drive the voltage (or at least I thought I was) through the coil, and then utilizing the normally open relay to of course close the contact circuit when power is fed.? Unfortunately I don't think I am doing this right, as I thought originally that the 12V trigger from the PW link could be fed directly to the QM-RMC based on page 1 of the manual.? Looking at it further, it is clear that as mentioned it can't accept the 12V signal.
Hope that explanation makes a bit more sense for what I am looking for.? Thanks for the help and some education. I may just need to look at an optically controlled relay. |
V24R-Wall and DGE2
Hi All, I have a project with (2) setups like this (for control and TV) in a residence. I want to upgrade them, BUT... Crestron's replacement is the TSD-2220 which has a considerably smaller footprint.? The V24R-WALL is 24.5"W x 17"H. and of course, these units are installed in really nice wood and tile, respectively, making reductions VERY difficult! Has anyone found a good replacement for this big V24R hole? I'm assuming 3rd party. I'd love to know peoples ideas on this conundrum... TIA!! |
Re: QM-RMC 12V Trigger Output