Thanks in advance to anyone who can help me. I just finished the Fusion class last week but the answer to this question was only partially answered and now I regret not asking enough questions during the class.

It was explained to me in class if I have 1 processor running 3 rooms than I can add 3 SSI Modules (main module) to the program and make sure the SSID is different. Do I now need to add 3 "Fusion Room" symbols to the Ethernet Slot or somehow tie them all to the same Fusion Room symbol?

I only ask this because I was told that a program can only have 1 Fusion Room in it but if I only use 1 and try to tie 3 SSI modules than i would get jammed signals and I can't see this working properly. My gut says to use 3 Fusion Rooms but I remember being told you cant have more than 1 per program.

Shawn




Re: DIN-CENCN-2(-POE) anyone used it? I'm not impressed!

 

I have latest TB on a different VM to my normal production VM. Always the same issue.


Re: DIN-CENCN-2(-POE) anyone used it? I'm not impressed!

 

same ver of toolbox?


Re: DIN-CENCN-2(-POE) anyone used it? I'm not impressed!

 

To update this.
I still can't connect to these by USB on my MBP /Parallels combo. However my boss using MBP boot camp win10 had no problems connecting.


Re: DIN-CENCN-2(-POE) anyone used it? I'm not impressed!

 

No they can be outside the range and you can change them no problem.
ReportCresnet is your friend.
-s


Re: DIN-CENCN-2(-POE) anyone used it? I'm not impressed!

 

Does anyone know if I need to change Cresnet IDs to within the range accepted by the DIN-CENCN-2 before I connect them to the unit, or can I still access and change them after they are connected?

I'm thinking of Lincoln's earlier comment:

Just beware that it has a hard limit of 20 devices per leg ¨C as in only IDs 03-1B are available ¨C so pay careful attention to designers and consultants who may either try pushing limits or specifying Cresnet IDs that aren¡¯t accessable from programming

?(I nearly got bit by this a few months mack in Infinet ¨C the devices will let you set any ID from 03-FE, so an installer helpfully logically addressed them by floor even though every floor had its own gateway (e.g. 10-1F first floor¡­70-7F 7th?floor) but you only have access to 6something in SIMPL.


On Thu, Jun 15, 2017 at 4:13 AM, slip.cougan@... [Crestron] <Crestron@...> wrote:
?

Guys,


Thanks for the feedback.
What I've noticed is that all feedback &?ReportLightLevel works fine after a cold start but breaks after a ProgReset or ProgLoad.

I have another 8 here so I'll try the others and check that I don't have a dud.

Cheers
-s



Re: HR150 - Battery pull/Battery repalcements often?

 

I have seen this happen on a few remotes. ?Haven't figured out if it's a bad battery connection or something else.


Re: Content and Control over HDBT

 

It's just Ethernet over HDBT, so you need an IP module for the projector or a Crestron Connected Display module from Crestron database. ?Crestron connected features, if built in, may need to be enabled and assigned an IP ID. ?Sometimes you have to convert IP ID value from decimal to hex.

On Jul 3, 2017 12:24 AM, "titoortiz21@... [Crestron]" <Crestron@...> wrote:
?

Got new project.


Components are: DM-MD16x16 and NEC NP-PA53UJL Projectors and a CP3 processor.


The content and control are over HDBT for all projectors, and I haven¡¯t done controlling devices over HDBT.


Any advice??
-thank you!




Re: Content and Control over HDBT

 

I haven't done this, but from what I have seen when you configure your output cards for the receiver you choose HDBaseT Receiver and then just add your serial driver for that device. Im not 100% as I have not done it, but that's what I see.


-Chris

On Monday, July 3, 2017, 12:24:08 AM EDT, titoortiz21@... [Crestron] wrote:


?

Got new project.


Components are: DM-MD16x16 and NEC NP-PA53UJL Projectors and a CP3 processor.


The content and control are over HDBT for all projectors, and I haven¡¯t done controlling devices over HDBT.


Any advice??
-thank you!



Re: Lutron Radio Ra2 r05 Maestro Dimming module not working properly

 

i see the start/stop commands
I don't see the Y & Z values being sent as part of the string
just ramp to X value
I see the Y & Z values are passed in, but don't seem to be added to the string
maybe needs a MSP to make it work - i'll add one & see what happens

?mark


Content and Control over HDBT

 

Got new project.


Components are: DM-MD16x16 and NEC NP-PA53UJL Projectors and a CP3 processor.


The content and control are over HDBT for all projectors, and I haven¡¯t done controlling devices over HDBT.


Any advice??
-thank you!



Re: Lutron Radio Ra2 r05 Maestro Dimming module not working properly

 

It sounds like the raise/lower button is being released inadvertently. For Raise and Lower, the module sends a "start ramp" command when the buttons are pressed, then a "stop ramp" command when they're released. The stop command isn't exposed outside the module.

The analog input sends a single command to "ramp to X value, over Y period of time, after Z delay ", triggered by a Serial/Analog One-Shot. It's hard to say what would cause that to not work, without seeing the code.

--- On Sunday, July 2, 2017 8:20 AM, Mark wrote:

I am trying to use raise/lower to a Maestro dimmer module

I have had to fix the modules to be threadsafe, no THREADSAFE keyword or
semaphore implemented a single press works OK, but if you hold either
raise/lower, I see the analog feedback change but then bounces back about
1/2 way as the true feedback never catches up

there is a ramp in the module to simulate the feedback until the Lutron
side catches up

I watch the debugger and see the artificial feedback, but it only sends a
couple of values to the actual Lutron system, the last being about 1/2 way
through the ramping

I have tried just using the analog (not raise/lower) same thing, the
Maestro module doesn't send out a string for each analog change

mark


Re: DM endpoints power

 

Thanks everyone for the suggestions, I just remove that jumper, and everything worked.


New file uploaded to Crestron

 

Hello,

This email message is a notification to let you know that
a file has been uploaded to the Files area of the Crestron
group.

File : /IR Drivers/Flir M3100.ir
Uploaded by : keith.gossen <kgossen@...>
Description : Flir DVR remote for M Series 4-8-16 Channel

You can access this file at the URL:


To learn more about file sharing for your group, please visit:


Regards,

keith.gossen <kgossen@...>


Panasonic TX-55EZW954

 

Sehr geehrte Mitglieder,
f¨¹r oben benanntes Panasonic OLED-Ger?t suche ich ein Crestron-Macro.
Kann mir ein Mitglied helfen?
mit freundlichen Gr¨¹?en
Akhnaforest

Dear members,
for above-mentioned Panasonic OLED device I`m looking for a Crestron Maco.
Can a member help me?
Best regards
akhnaforest


SG tv presets Fios NY

 

Does anyone have an xml file for Fios? I know I can edit one myself but I am under the gun trying to get 2 projects done that want it by the 4th.


TIA if anyone can post it


Happy 4th of July


Re: Mobotix T25 camera and TSW-x60's?

 

Try the following:
rtsp://<IPADDRESS>:554/stream0/mobotix.mjpeg

These worked for me.


Re: Mobotix T25 camera and TSW-x60's?

 

seems to be known issue with TB
no solution yet

?mark


Lutron Radio Ra2 r05 Maestro Dimming module not working properly

 

I am trying to use raise/lower to a Maestro dimmer module

I have had to fix the modules to be threadsafe, no THREADSAFE keyword or semaphore implemented

a single press works OK, but if you hold either raise/lower, I see the analog feedback change but then bounces back about 1/2 way as the true feedback never catches up

there is a ramp in the module to simulate the feedback until the Lutron side catches up

I watch the debugger and see the artificial feedback, but it only sends a couple of values to the actual Lutron system, the last being about 1/2 way through the ramping

I have tried just using the analog (not raise/lower)

same thing, the Maestro module doesn't send out a string for each analog change