OSC Protocol - Website Down
Does anyone have a copy of the OSC protocol standards? I have a project coming up that leans heavily on this and the website has been down for at least a week now. I've been looking around the net but just finding bits and pieces so I figured maybe someone on here has a full copy laying around?
?(currently down along with the entire site) Thanks in advance! Dustin |
Re: S+ Basic Question
"some of the complex logic either takes 30 steps in Simpl or can't be done at all (at least not by me) and I can get it done with 5 lines of S+ code. Those are the circumstances I will revert to S+." Here's the thing with that though, you're invoking a task switch each time you leave Simpl to do something in S+. If you're on 3-series processors, it's harder to tell because they're so much faster, but if you're on a 2-series processor you really need to find a good justification as to why you should jump out to S+. 30 steps in Simpl is not a big deal, particularly when dealing with a fast changing analog or serial.
|
Re: pyng wired devices
I talked to true blue about this as I wasnt sure if 200 was the max for infinet ex with expanders or if it was max total including wired devices. They told me that 200 was indeed the max for ALL devices both wireless and wired, this is the max the processor can handle, they also told me this isnt a hard cut off thats just what they guarantee. for instance if you had 210 devices it would most likely still work fine.
|
Re: Windows 10 indexing error?
I found this, it helped with my system when it was taking ages to create a new folder. It may help with this problem??
? |
Maximum IR files on a port
What is the limit of IR files on a single IR port? There will only ever be a single IR controlled device on each port but it must be configurable at run time. The scenario is a fully configurable program, on the touch panel I can select from a list of IR controlled devices and assign them to any port, the problem is that you cannot dynamically load IR files so my SIMPL program has to have every possible IR file loaded into every possible port and then the program uses crosspoint to route the controls to the correct driver file. It has to run on 2 and 3 series processors so I don't have the option of S#. I'm currently up to 5 IR files on each IR port but expect to add many more devices as needed, I am wondering when I will hit the limit and what will happen once I hit the limit. Is it a memory limitation or does SIMPL stop letting me drop IR files onto the port? |
Re: Adding a new device to a project
Has the module been configured for both 2 and 3 series processors?
|
Adding a new device to a project
I have an old project I'm working on where I need to swap the AVR for a new Anthem serial-controlled model.? I have the .umc file and I copied it to the SIMPL/USRMACRO directory, but I can't get it to appear in the User Devices list, even after reloading the libraries from disk and rebuilding the database.
I confirmed that I'm using the correct directory for user modules. What am I missing? ?- Dave |
Re: Windows 10 indexing error?
Heather Baiman
Crestron is aware of the symlib.tio error which has been around for several months now. Pretty sure it affects all windows versions. For me it happens on Win7 and simply closing Simpl and re-opening makes it go away.
________________________________________ From: Crestron@... [Crestron@...] Sent: Sunday, February 21, 2016 4:21 AM To: Crestron@... Subject: [Crestron] Windows 10 indexing error? I am getting a weird intermittent error in Simpl, it happens ¡®sometimes¡¯ when opening a module (i haven¡¯t seen it when opening a .smw) or re-synching a program. An error message appears saying ¡°Couldn¡¯t open file : c:\Program Files (x86)\Crestron\CresDB\Programming\symlib.tio - Be sure that the system indexing service is is disabled for SIMPL working directory ¡°smpwinWK¡±¡± To remove any uncertainty, I have completely disabled the indexing service in Windows 10 but am still seeing this, so it clearly has nothing to do with that. I have removed, rebooted and reinstalled SIMPL, but it hasn¡¯t helped. I have also tried running SIMPL (and Toolbox) in compatibility mode with Windows 8, to no avail. I am not saving anything to a Dropbox or SpiderOak monitored directory¡¡. Does anyone have any idea what might going on? ------------------------------------ Posted by: Marc Nield <marc@...> ------------------------------------ Check out the Files area for useful modules, documents, and drivers. A contact list of Crestron dealers and programmers can be found in the Database area. ------------------------------------ Yahoo Groups Links ============================================================================ Please refer to for important disclosures regarding this electronic communication. ============================================================================ |
Re: Panasonic AW-HE130
Hi group,
It appears that there still is trouble with Panasonic cameras. I'll soon have to control (PTZ and presets) 39 AW-HE40 via IP. If someone? have a working module or any tips for this specific reference, he will deserves a drink or more if he come to Lyon (France). Best regards. Matthieu |
Crestron & Mobotix SIP serwer
Can someone please help with some advice how to connect Crestron and Mobotix S14 using SIP serwer? I want to do this on iPad ( Crestron app) and on the mobotix camera model S14. On visualization Crestron ( iPad) I want to use the reserved join. I made the connection between Crestron and Mobotix in VoIP setting in Crestron app. So when I choose "dial" a have audio connection and I can speak. But on my vizualization, when I call on the mobotix camera, I don't have any notifications like the reserved join dont't work. I wonder why this is so that the connection between the application Crestron and MOBOTIX working but visualization did not respond to the call from the intercom. Do I have to create a user for Mobotix sip server and connect it to the iPad where the application is Crestron? |
Re: AIRZONE
toggle quoted message
Show quoted text
? |
Windows 10 indexing error?
I am getting a weird intermittent error in Simpl, it happens ¡®sometimes¡¯ when opening a module (i haven¡¯t seen it when opening a .smw) or re-synching a program. An error message appears saying ¡°Couldn¡¯t open file : c:\Program Files (x86)\Crestron\CresDB\Programming\symlib.tio - Be sure that the system indexing service is is disabled for SIMPL working directory ¡°smpwinWK¡±¡±
To remove any uncertainty, I have completely disabled the indexing service in Windows 10 but am still seeing this, so it clearly has nothing to do with that. I have removed, rebooted and reinstalled SIMPL, but it hasn¡¯t helped. I have also tried running SIMPL (and Toolbox) in compatibility mode with Windows 8, to no avail. I am not saving anything to a Dropbox or SpiderOak monitored directory¡¡. Does anyone have any idea what might going on? |