Re: Wire control of Haivision Stingray2?
Crestron FTP under _discontinued_software\windeal On Thu, Feb 18, 2016 at 9:54 AM, FBC Tech Team sound@... [Crestron] <Crestron@...> wrote:
|
Re: Wire control of Haivision Stingray2?
On Thu, Feb 18, 2016 at 4:40 AM, phil@... [Crestron] <Crestron@...> wrote: Open the IR driver in Deal or Toolbox and save it without carrier. Presto. Phil, Are you talking about in Device Learner in Toolbox? If so, there wasn't an option that we saw to save without carrier, either with the IR file that we "learned" or the Crestron Haivision "Set Top Box" IR file. We also can't find DEAL anywhere...it's not something we've used, but recognize the name, but we can't find it online or on our Crestron PC anywhere. Thanks, Jeff ------------------------------------- Jeff Klein, DMC- E Audio Visual Project Manager Dept of Defense Washington D.C. District ?"Clothe yourselves, all of you, with humility toward one another, for God opposes the proud but gives grace to the humble." 1 Peter 5:5 |
help with creating lighting scenes
client wants to be able to create, edit, delete and rename lighting scenes in his system on the touchpanel.
something like this: - press create lighting scene button - pick the loads affected and set the levels - save and name the scene - the scene will then appear on the list if saved is there a module that works like this? |
Re: S+ Basic Question
Some friendly advice... figure out how to do things in SIMPL first.? SIMPL+ is not designed to build your whole system, it's built as an "escape hatch" when the SIMPL logic or string parsing gets too complicated.? It may sound like a great idea to do everything in SIMPL+ right now, but the collective experience of this group has showed that it always ends in tears. On Wed, Feb 17, 2016 at 9:17 PM, enidsaldin@... [Crestron] <Crestron@...> wrote:
|
Re: can't communicate with QM-RMC
Hi all I Got it worked for me,,
I will be the problem with configuration of IP adress Here What it is : Go to system info and check the SSL : <Dissabled>? if it is dissabled and self assigned you need to make it enabled by putting it to DHCP. this mode will assign an ip and remove SSL support? you will get SSLL<Not supported> then reassign your IP to static....!!!! it works like champ.. for me Thanks? Regards; Shridhar. CSD India (P) Ltd.,Bangalore, India www.csdav.com |
Re: OT: DMX Lighting Fixtures
¿ªÔÆÌåÓýNo need to special module. You need just Intersystem Communications. More info at in the resource section.D¨¾a 18.2.2016 o 3:41
johnkennethsantiago@... [Crestron] nap¨ªsal(a):
? |
Re: Wire control of Haivision Stingray2?
So Phil, is there a way to strip out the carrier frequency? We figured out that we do indeed need to convert the modulated codes that the CP3 would send out of its IR port into the demodulated code that the receiving IR bud would put out, but we're having trouble figuring out how to do that. Haivision is trying to help, but we're not quite there. Can the CP3 IR port even do that? Can any IR port? We really wanted to use the SVSi decoder IR control port for this, but it will only do IR outputs, not IR or serial like the CP3 can do, so if it has to be a serial output to simulate a demodulated signal, then we might not be able to use the SVSi method. Thanks,
Jeff ------------------------------------- Jeff Klein, DMC- E Audio Visual Project Manager Dept of Defense Washington D.C. District ?"Clothe yourselves, all of you, with humility toward one another, for God opposes the proud but gives grace to the humble." 1 Peter 5:5 On Tue, Feb 9, 2016 at 1:36 PM, FBC Tech Team <sound@...> wrote:
|
Re: S+ Basic Question
Well I actually didn't think she was being patronizing I just figured (based on some other 'lame' questions I have asked in the past she really thought I had no basic programming knowledge. I cop to struggling with Crestron programming (Simpl Windows in particular) having come from a very different programming background. However, I will probably find S+ more comfortable after playing with it a bit the past few days.?And I found the problem :) Thanks to everyone for the help and putting up with my somewhat lame questions. |
Re: Sonance DSP series amps
bruce pearce
¿ªÔÆÌåÓýHi? I have used these before . Great amps with ip control . The only problem is they take ages to turn on with an ip command . And while they are turning on they don't respond to any commands . From what I remember it's is about 2-3 minuets before it becomes operational from off? From bruce On 17 Feb 2016, at 18:17, lucas.christy@... [Crestron] <Crestron@...> wrote:
|
Sonance DSP series amps
Quoting an upcoming job where these will be used. Plan is to use these as a switcher/amp/volume control.?
Has anyone used these and is there anything to watch out for? There are downloads from the Sonance site for both IP and IR commands but no pre built modules. Has anyone developed a module for these? TIA. |
Re: Compile crashing
Andrew, ? ? I think you need to take a step back and calm down. Yes, I am aware that TB does not physically write the applications. My comment was simply to let the original poster be aware that this topic has come up on this forum before and months ago TB was aware of it. When TB is aware of it that typically means that the engineers are aware of it and since the problem is still occurring, we can only assume they have not made a fix for it yet. I am on CrestronLabs and am very familiar with the platform. As others have stated, that is not the correct path for a resolution. ? The correct path has already been taken. Called TB, reported the problem, confirmed the problem is known to Crestron, sit back and wait for them to get around to fixing it. I have been doing Crestron long enough to know that they will fix it when they want to and the rest of us just have to work around it. It has been like that for years. I don't have to like it, I just have to do my job. |