¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Streaming H.264 HDHomeRun & Smartgraphics

 

Has anyone had any luck streaming an HDHomeRun from Silicondust into a smart graphics Embedded Video Object? ? ?I can see the stream at http://192.168.1.140:5004/auto/v8.1?in VLC and it shows the stream is H.264.

?


Re: First Time use of Smart Graphics TV Preset

 

Did anyone ever end up making Directv files they'd be willing to post?


Re: Toolbox (ish)

 

So you got Simpl and VTPro to run in Linux?


Re: c2n-amp-4x100 dead?

 

¿ªÔÆÌåÓý

Thanks for all the suggestions. It turns out to have been a dying old Squeezebox on one of the inputs via a Kramer switch. It looks as if it was working properly but when I disconnected it from the switch, everything came back to life. I guess I need to check the switch as well¡­..

Anyhow, thanks again.

On 2 Feb 2016, at 23:48, stefuel@... [Crestron] <Crestron@...> wrote:


If NOTHING has changed in the system then do as suggested.? Pull all the inputs and see if the noise is still there.? Then pull one output at a time.? Not sure what else is in the rack but try pulling the coax inputs off the cable boxes. You could be grabbing ground loop from the street.? If all else fails start looking at the amps power supply for swollen/leaking electrolytic capacitors.
?
In a message dated 2/2/2016 9:50:28 A.M. Eastern Standard Time, Crestron@... writes:
?

In Addition to Michael's suggestion of a ground loop... Try disconnecting _everything_ (inputs and outputs) and adding things back one at a time (one source and one output) to see if perhaps something up or downstream has made it particularly unhappy.?



--?
Lincoln King-Cliby, CTS, DMC-E-4K/T/D?
Commercial Market Director?
Sr. Systems Architect | Crestron Certified Master Programmer (Gold)?
ControlWorks Consulting, LLC?
V: 440.449.1100 x1107 F: 440-449-1106 I: ?
Crestron Services Provider | Biamp Audia Certified | Extron Authorized Programmer?


-----Original Message-----?
From: Crestron@... [mailto:Crestron@...]?
Sent: Tuesday, February 02, 2016 2:15 AM?
To: Crestron@...?
Subject: [Crestron] c2n-amp-4x100 dead??

Yesterday everything was working just fine. I made no changes to any programs or configuration, but today I just get a buzz (medium pitched similar to one of those annoying scooters, varies with volume) out of all channels. I have tried the obvious, unplug from main, leave it a while, reload firmware, but no change. I can¡¯t even claim that it is tired and sh4gged out after a prolonged squawk, t¡¯s only ever been used for internet radio, some dinner music and such via ceiling speakers.?

Does anyone have any idea what else I might be able to try before I declare it demised??

------------------------------------?
Posted by: Marc Nield <marc@...>?
------------------------------------?

?

Check out the Files area for useful modules, documents, and drivers.?

A contact list of Crestron dealers and programmers can be found in the Database area.?
?
------------------------------------?

Yahoo Groups Links?






Re: SIP camera to IPAD app

Jayson Small
 

I think Siedle ()?makes the Mobotix SIP door camera.

Jayson

From: <Crestron@...> on behalf of "ripper99@... [Crestron]" <Crestron@...>
Reply-To: <Crestron@...>
Date: Wednesday, February 3, 2016 at 1:48 PM
To: <Crestron@...>
Subject: [Crestron] Re: SIP camera to IPAD app

?

You can do this with Mobotix cameras and the Mobotix app however I am not so sure about integration with the Crestron app, I know some programmers were able to get a TPMC-4SM-FD working with the Mobotix T24/T25 doorstation but not sure about the other models.


Re: Latest SWAMP firmware: Added doorbell feature capabilities

Andrew Welker
 

I'm not that familiar with the SWAMP, but have you checked if there is an option, either with toolbox or on the SIMPL symbol, to disable the amp power off? Seems to me this should be optional behavior and have a checkbox somewhere.


On Wed, Feb 3, 2016, 1:50 PM?ripper99@... [Crestron] <Crestron@...> wrote:
?

Hi Ross, thanks for the suggestion and this might work but I have no unused zones and I think if I implemented something like that the feedback is gonna show a zone as always being on the way most modules work, probably cause confusion.


Re: Help!!! Remote CP2E Processor locked up!

 

Very important rule to follow...Don't do anything remotely with a processor without at least one of the following two things put in place:

1- Have someone on site to immediately deal with a locked up or unreachable system.
2 - Let the client know that you will be connecting to the system and there is a chance that it will go done until you can get back out to the site.


Re: Latest SWAMP firmware: Added doorbell feature capabilities

 

Hi Ross, thanks for the suggestion and this might work but I have no unused zones and I think if I implemented something like that the feedback is gonna show a zone as always being on the way most modules work, probably cause confusion.


Re: SIP camera to IPAD app

 

You can do this with Mobotix cameras and the Mobotix app however I am not so sure about integration with the Crestron app, I know some programmers were able to get a TPMC-4SM-FD working with the Mobotix T24/T25 doorstation but not sure about the other models.


Re: Latest SWAMP firmware: Added doorbell feature capabilities

 

¿ªÔÆÌåÓý

Can you keep an unused zone on 24:7 at 0 volume? ?


On Feb 3, 2016, at 12:14 PM, ripper99@... [Crestron] <Crestron@...> wrote:

?

I just tested this the past hour and my doorbell is working again but *only* if I add a 4.5 second delay before my Play Doorbell sequence, if I don't do this and all zones are OFF then I never hear the doorbell at all.


Basically when the interrupt is pulsed I guess its turning on the amp so all zones are ready however in the past the amp was in a state where it would play right away.

The revision history for the firmware says this?

Firmware?SWAMP24X8: v4.002.283411084

*** Revision History Build 1.39 November 6, 2015 ©\?added feature that turns amp off if all zones are turned off ©\?eliminated??erroneous start©\up messages ©\?corrected start©\up volumes higher thatn 50% in outputs 5©\8 ©\?added doorbell feature capabilities



Perhaps this new firmware they created makes things faster for doorbells IF you have at least one zone on but if not it slows down everything by at least 4 seconds.

Another example of how this slows things, I notice now when I turn on a room and choose a source such as AM/FM that it takes about 4 seconds for audio to be heard from this source IF all other zones are off, before I would choose AM/FM and it would turn on immediately and you hear the audio in about 1 second.


I'm pretty sure anybody using the interrupt feature will notice that announcements, doorbells, chimes etc may not work that same as they did before if they upgrade to this firmware, time will tell.



Re: Latest SWAMP firmware: Added doorbell feature capabilities

 

I just tested this the past hour and my doorbell is working again but *only* if I add a 4.5 second delay before my Play Doorbell sequence, if I don't do this and all zones are OFF then I never hear the doorbell at all.

Basically when the interrupt is pulsed I guess its turning on the amp so all zones are ready however in the past the amp was in a state where it would play right away.

The revision history for the firmware says this?

Firmware?SWAMP24X8: v4.002.283411084

*** Revision History Build 1.39 November 6, 2015 ©\?added feature that turns amp off if all zones are turned off ©\?eliminated??erroneous start©\up messages ©\?corrected start©\up volumes higher thatn 50% in outputs 5©\8 ©\?added doorbell feature capabilities



Perhaps this new firmware they created makes things faster for doorbells IF you have at least one zone on but if not it slows down everything by at least 4 seconds.

Another example of how this slows things, I notice now when I turn on a room and choose a source such as AM/FM that it takes about 4 seconds for audio to be heard from this source IF all other zones are off, before I would choose AM/FM and it would turn on immediately and you hear the audio in about 1 second.


I'm pretty sure anybody using the interrupt feature will notice that announcements, doorbells, chimes etc may not work that same as they did before if they upgrade to this firmware, time will tell.



Re: Latest SWAMP firmware: Added doorbell feature capabilities

 

I tested this again, the CEN-TIA is connected to Cresnet and not?Ethernet and works fine but I believe the problem has to possibly do with the new firmware turning off the amp *power* when all zones are off, I don't think it did this before.

So now with the module I was using with an interrupt the *only* way it works now is I have to turn on a source in *any* zone and only then can I hear when the doorbell is pressed, I will test using a delay of say 4 seconds to give the amp time to power on.

I'm not sure how this firmware would speed up doorbells and the interrupt IF the amp now is powered off when all rooms are OFF, if this is the case I doubt it made things faster and in my case it broke something.

CEN-TIA I am using has work fine since 2009, was working fine just hours before the firmware was upgraded also.


SIP camera to IPAD app

 

I have a client who wants to put a camera in the kids playroom, and be able to view and talk TWO WAY to the kids in that room via Crestron App. ?There are no speakers in the room.


I was thinking a SIP cameras with audio might fit the bill. ?Anyone have any recommendations or pitfalls to avoid?


Re: Using CEC with DM8x8 to my SamsungTV

Georges Tabet
 

Dear?

I am wondering if you can send me the codes for Samsung Anynet + CEC I m using DM-MD 1616 with DMC-HDO and DM-RMC-200
I tried the Crestron module it is not working.
Anynet+ is on on the TV?

Regards?




On Tuesday, September 1, 2015, 23:30, basti76nie@... [Crestron] wrote:

?

No sorry! Only PON and POF and HDMI 1 - 4 worked.
Could you choose the Source TV by CEC?


Re: MC3 - remote Ethernet slave & a local program; at the same time?

 

Just use a EISC. Why 2 MC3's?


Re: BACnet

Mark Conde
 

Yeah that is a bit?different and a perfect case scenario, you have a controller that the thermostats connect to.?
You communicate with the main controller unit, it communicates with the thermostats.
My Situation consists of a thermostat wired directly into the Damper unit itself..


On Sunday, January 31, 2016 1:13 PM, "Joe Vossen jkvossen@... [Crestron]" wrote:


?
Not sure what type of damper unit you are connecting to; I have 5 HAI thermostats connected to a Honeywell zone controller controlling 5 dampers with all of the HAI tstats being controlled through a serial port on a QM-RMC and the QM-RMC talking to a CP3N.....works fine

On Jan 31, 2016, at 12:38 PM, Mark Conde mcjaran@... [Crestron] <Crestron@...> wrote:


Looked at the install instructions for the HAI Thermostat and seems to be design for a standard HVAC Unit.

I need it to control a single zone Damper unit.

Thanks anyways. I appreciate the suggestion.



Re: Emailing from 3-Series

 

Crestron's IP address is added to the whitelist, it just rejects the email because Crestron is trying to authenticate with blank username and password. ?I'm going to try using a 2-series first. ?Hopefully that'll work. ?Otherwise I will try the TEK 3 solution.


Re: Emailing from 3-Series

 

Since you have a server available already, you could install an SMTP relay on the Fusion server that accepts mail from localhost:25 and sends it via TLS/SMTP AUTH to the appropriate host.

On Tue, Feb 2, 2016 at 8:35 PM, jcallaghan0176@... [Crestron] <Crestron@...> wrote:
?

Most?mail servers use TLS and other forms of authentication. The mail server authenticates the username and password and then relays it to the SMTP server. The SMTP server will only allow packets sent from a whitelist.? If you don't have them put the Crestron IP address in that whitelist you will never be able to send mail.

?

We came across this with Fusion. We were not doing exchange integration and wanted to send mail. Fusion only supports SMTP on port 25. There is no way to change it or enable higher forms of authentication. The only work around was to add the Fusion server to the whitelist and allow it to communicate to the mail relay.



Re: Text Entry Field Example (Smart Graphics)

 

Thanks for the response. I'm away from the office without benefit of a processor, so I am not able to test with an xpanel.?


Re: Latest SWAMP firmware: Added doorbell feature capabilities

 

I'll check this tonight when I'm free, thanks for the tips.