Re: Media Matrix Xfram88

 

Tres, you're thinking Nion. xframe88 uses rs485 and a simple set/get protocol utilising three digit ID numbers and two digit values iirc... There is a word document with the serial control protocol that gets installed with xware. I'm fairly sure Chip posted a module to the files section many moons ago.

Regards
ʳ󾱱

Sent from my Samsung Galaxy Tab 10.1

[Non-text portions of this message have been removed]


Re: Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm

 

Nagel ends up getting used to more efficiently transfer data, given that if you want to transmit a single byte, the overhead is huge on a TCP/IP packet.

For a console session, I can see them wanting to. You want the data as it happens, not in "spurts" as the system decides to gather it up and transfer it in a lump according to however Nagel decides.

But, that's just my guess.

--- In Crestron@..., "xymox1357" <public2@...> wrote:


Hi Chip,

Thanks for responding.

I removed ALL the ethernet devices and removed the networktime sync and it still does it. Exactly once a minute.

Really annoying.

Maybe its time to ask trueblue cuz i have no way of knowing what this error means or what to diagnose.

Why in the world something on crestron would need to disable the Nagle algorithm and then what would cause it to not be able to is just a mystery.

Im now wondering if something from the outside is causing this error, maybe something on the network is sneding something to its IP address and causing this ?

--- In Crestron@..., "Chip" <cfm@> wrote:


What devices do you have configured in your program on the Ethernet interface?

- Chip


--- In Crestron@..., "xymox1357" <public2@> wrote:

Im seeing these once a minute in the log and im not sure whats causing them

--- In Crestron@..., "xymox1357" <public2@> wrote:


I am seeing a lot of these errors in my log. What does this mean ? They seem to occur about once a minute. Very annoying.

Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm for Console Sockets.


Re: Vtpro-e or Windows (saving a file with version number no longer works)

 

Tell trueblue something have been broke in the last update.

{Paf}
Le 10 juin 2013 15:06, "avsystemdesign" <avsystemdesign@...> a crit :

**


This has to be a Vtpro-e thing, as Simpl Windows still lets me save
version numbers. For some very strange reason Vtpro-e cuts off any file
name characters after the period. WTF!?

--- In Crestron@..., "avsystemdesign" <avsystemdesign@...>
wrote:

I'm not sure if this is a Vtpro-e thing or Windows...
I normally save a new file as v1.1, followed by v1.2 etc.
But, Vtpro-e won't do that anymore, it does not see the .2 for example,
so instead it saves it as v1 (which can for obvious reason wreck havoc).

Anyone come across this? Is there a patch or workaround?


[Non-text portions of this message have been removed]


Re: Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm

 

I have maybe an answer for you. Do you know id the network sending RIPV1
request on the network.

I got an issue of a mpc-m5 reaetting every minute due of that and i have
that measage in the error lof of another processor and i think the error
message stop when the client turn off that request on the network.

Maybe a conicidence.

{Paf}
Le 11 juin 2013 04:03, "xymox1357" <public2@...> a crit :

**


OK I initialized and reset the Pro 2. I then loaded a blank Pro2 program.

I still get the errors..

I have uploaded a SystemInfo dump of the system with the errors and a
blank Pro2 program.



--- In Crestron@..., "xymox1357" <public2@...> wrote:


Hmmmm.....

Even more confuzing... I deleted ALL my ethernet devices and the error
continued.




--- In Crestron@..., "xymox1357" <public2@> wrote:


Hmmmmmmm....

According to the Series 2 reference guide page 108
,d.dmQ&cad=rja

"Internal system error. Contact Crestron."

Whats weird is I was using a CP2E and it had this error and I switched
to a pro2 and it has this error.



--- In Crestron@..., "xymox1357" <public2@> wrote:


Hi Chip,

Thanks for responding.

I removed ALL the ethernet devices and removed the networktime sync
and it still does it. Exactly once a minute.

Really annoying.

Maybe its time to ask trueblue cuz i have no way of knowing what
this error means or what to diagnose.

Why in the world something on crestron would need to disable the
Nagle algorithm and then what would cause it to not be able to is just a
mystery.

Im now wondering if something from the outside is causing this
error, maybe something on the network is sneding something to its IP
address and causing this ?

--- In Crestron@..., "Chip" <cfm@> wrote:


What devices do you have configured in your program on the
Ethernet interface?

- Chip


--- In Crestron@..., "xymox1357" <public2@> wrote:

Im seeing these once a minute in the log and im not sure whats
causing them

--- In Crestron@..., "xymox1357" <public2@> wrote:


I am seeing a lot of these errors in my log. What does this
mean ? They seem to occur about once a minute. Very annoying.

Error: CConsoleListenSocket::AcceptConnection: unable to
disable Nagle algorithm for Console Sockets.


[Non-text portions of this message have been removed]


Re: Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm

 

I've seen this error, but can't for the life of me remember what
the solution was. Did you try disconnecting the network cable
and monitoring the processor via serial to see if it still happens?

Have you set SHOWEXTRAERRORS ON? That may give something helpful
-noob

--- In Crestron@..., "xymox1357" <public2@...> wrote:

OK I initialized and reset the Pro 2. I then loaded a blank Pro2 program.

I still get the errors..

I have uploaded a SystemInfo dump of the system with the errors and a blank Pro2 program.



--- In Crestron@..., "xymox1357" <public2@> wrote:


Hmmmm.....

Even more confuzing... I deleted ALL my ethernet devices and the error continued.




--- In Crestron@..., "xymox1357" <public2@> wrote:


Hmmmmmmm....

According to the Series 2 reference guide page 108
,d.dmQ&cad=rja

"Internal system error. Contact Crestron."

Whats weird is I was using a CP2E and it had this error and I switched to a pro2 and it has this error.



--- In Crestron@..., "xymox1357" <public2@> wrote:


Hi Chip,

Thanks for responding.

I removed ALL the ethernet devices and removed the networktime sync and it still does it. Exactly once a minute.

Really annoying.

Maybe its time to ask trueblue cuz i have no way of knowing what this error means or what to diagnose.

Why in the world something on crestron would need to disable the Nagle algorithm and then what would cause it to not be able to is just a mystery.

Im now wondering if something from the outside is causing this error, maybe something on the network is sneding something to its IP address and causing this ?

--- In Crestron@..., "Chip" <cfm@> wrote:


What devices do you have configured in your program on the Ethernet interface?

- Chip


--- In Crestron@..., "xymox1357" <public2@> wrote:

Im seeing these once a minute in the log and im not sure whats causing them

--- In Crestron@..., "xymox1357" <public2@> wrote:


I am seeing a lot of these errors in my log. What does this mean ? They seem to occur about once a minute. Very annoying.

Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm for Console Sockets.


Re: Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm

 

OK I initialized and reset the Pro 2. I then loaded a blank Pro2 program.

I still get the errors..

I have uploaded a SystemInfo dump of the system with the errors and a blank Pro2 program.

--- In Crestron@..., "xymox1357" <public2@...> wrote:


Hmmmm.....

Even more confuzing... I deleted ALL my ethernet devices and the error continued.




--- In Crestron@..., "xymox1357" <public2@> wrote:


Hmmmmmmm....

According to the Series 2 reference guide page 108
,d.dmQ&cad=rja

"Internal system error. Contact Crestron."

Whats weird is I was using a CP2E and it had this error and I switched to a pro2 and it has this error.



--- In Crestron@..., "xymox1357" <public2@> wrote:


Hi Chip,

Thanks for responding.

I removed ALL the ethernet devices and removed the networktime sync and it still does it. Exactly once a minute.

Really annoying.

Maybe its time to ask trueblue cuz i have no way of knowing what this error means or what to diagnose.

Why in the world something on crestron would need to disable the Nagle algorithm and then what would cause it to not be able to is just a mystery.

Im now wondering if something from the outside is causing this error, maybe something on the network is sneding something to its IP address and causing this ?

--- In Crestron@..., "Chip" <cfm@> wrote:


What devices do you have configured in your program on the Ethernet interface?

- Chip


--- In Crestron@..., "xymox1357" <public2@> wrote:

Im seeing these once a minute in the log and im not sure whats causing them

--- In Crestron@..., "xymox1357" <public2@> wrote:


I am seeing a lot of these errors in my log. What does this mean ? They seem to occur about once a minute. Very annoying.

Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm for Console Sockets.


Re: Another samsung ex-link question

 

Thanks guys for the input, polling was the cause of the on-screen pop up.

--- In Crestron@..., Jeremy Weatherford <jweather@...> wrote:

PRO2


On Mon, Jun 10, 2013 at 12:58 PM, Oliver <oliver@...> wrote:

Jeremy

Was that at 3 series job?

--- In Crestron@..., Jeremy Weatherford <jweather@> wrote:

FYI, we ran across a TV last week (UN46ES7500F) that would only respond
to
"off" commands from a 1-way 232 port, not from a full COM port. Maybe
EX-Link expects TTL levels and gets overdriven by standard 232? No idea,
this is the first time I've seen this, but then we usually have these on
1-way 232 ports anyway...



------------------------------------




Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the
Database area.
Yahoo!
Groups Links




--
Jeremy Weatherford


[Non-text portions of this message have been removed]


Re: Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm

 

Hmmmm.....

Even more confuzing... I deleted ALL my ethernet devices and the error continued.

--- In Crestron@..., "xymox1357" <public2@...> wrote:


Hmmmmmmm....

According to the Series 2 reference guide page 108
,d.dmQ&cad=rja

"Internal system error. Contact Crestron."

Whats weird is I was using a CP2E and it had this error and I switched to a pro2 and it has this error.



--- In Crestron@..., "xymox1357" <public2@> wrote:


Hi Chip,

Thanks for responding.

I removed ALL the ethernet devices and removed the networktime sync and it still does it. Exactly once a minute.

Really annoying.

Maybe its time to ask trueblue cuz i have no way of knowing what this error means or what to diagnose.

Why in the world something on crestron would need to disable the Nagle algorithm and then what would cause it to not be able to is just a mystery.

Im now wondering if something from the outside is causing this error, maybe something on the network is sneding something to its IP address and causing this ?

--- In Crestron@..., "Chip" <cfm@> wrote:


What devices do you have configured in your program on the Ethernet interface?

- Chip


--- In Crestron@..., "xymox1357" <public2@> wrote:

Im seeing these once a minute in the log and im not sure whats causing them

--- In Crestron@..., "xymox1357" <public2@> wrote:


I am seeing a lot of these errors in my log. What does this mean ? They seem to occur about once a minute. Very annoying.

Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm for Console Sockets.


Re: Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm

 

Hmmmmmmm....

According to the Series 2 reference guide page 108
,d.dmQ&cad=rja

"Internal system error. Contact Crestron."

Whats weird is I was using a CP2E and it had this error and I switched to a pro2 and it has this error.

--- In Crestron@..., "xymox1357" <public2@...> wrote:


Hi Chip,

Thanks for responding.

I removed ALL the ethernet devices and removed the networktime sync and it still does it. Exactly once a minute.

Really annoying.

Maybe its time to ask trueblue cuz i have no way of knowing what this error means or what to diagnose.

Why in the world something on crestron would need to disable the Nagle algorithm and then what would cause it to not be able to is just a mystery.

Im now wondering if something from the outside is causing this error, maybe something on the network is sneding something to its IP address and causing this ?

--- In Crestron@..., "Chip" <cfm@> wrote:


What devices do you have configured in your program on the Ethernet interface?

- Chip


--- In Crestron@..., "xymox1357" <public2@> wrote:

Im seeing these once a minute in the log and im not sure whats causing them

--- In Crestron@..., "xymox1357" <public2@> wrote:


I am seeing a lot of these errors in my log. What does this mean ? They seem to occur about once a minute. Very annoying.

Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm for Console Sockets.


Re: Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm

 

Hi Chip,

Thanks for responding.

I removed ALL the ethernet devices and removed the networktime sync and it still does it. Exactly once a minute.

Really annoying.

Maybe its time to ask trueblue cuz i have no way of knowing what this error means or what to diagnose.

Why in the world something on crestron would need to disable the Nagle algorithm and then what would cause it to not be able to is just a mystery.

Im now wondering if something from the outside is causing this error, maybe something on the network is sneding something to its IP address and causing this ?

--- In Crestron@..., "Chip" <cfm@...> wrote:


What devices do you have configured in your program on the Ethernet interface?

- Chip


--- In Crestron@..., "xymox1357" <public2@> wrote:

Im seeing these once a minute in the log and im not sure whats causing them

--- In Crestron@..., "xymox1357" <public2@> wrote:


I am seeing a lot of these errors in my log. What does this mean ? They seem to occur about once a minute. Very annoying.

Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm for Console Sockets.


Re: Device Firmware

 

If a S+ module uses THREADSAFE it will also require newer fw (rewrite to use a semaphore if this is the case).

--- In Crestron@..., Heather Baiman <heather@...> wrote:

4.003.0015 is not the latest firmware for the 2-series.

Most programs don't need to upgrade beyond this version unless you're doing stuff with Smart Graphics I think.
________________________________________
From: Crestron@... [Crestron@...] on behalf of Sebastian [s.marszalek11@...]
Sent: Monday, June 10, 2013 7:36 PM
To: Crestron@...
Subject: [Crestron] Device Firmware

Hey All,

I keep getting this message when I upload a program to a processor.

" The device firmware does not meet the minimum requirements of the File.

Device:4.003.0015(Oct 04 2010)
File:4.006"

This is the latest firmware for the device, anyone know why it's asking that?

Thank you,



------------------------------------



Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the Database area.
Yahoo! Groups Links


Re: Media Matrix Xfram88

Tres
 

Look in their manaul for the RATC2 protocol.. It is very straight forward.
The trickiest part is connecting over ethernet to the frame and its not
really that tricky.

I suggest creating your own user name and password for connecting from the
crestron processor.



From: Crestron@... [mailto:Crestron@...] On Behalf
Of ken santiago
Sent: Tuesday, June 11, 2013 12:38 AM
To: Crestron@...
Subject: [Crestron] Media Matrix Xfram88





Good Day,

Need Help in Controlling media matrix x-frame 88.
Just a sample code or module.

Really need to control media matrix xframe
Thanks in Advance.

Kenneth



_____

No virus found in this message.
Checked by AVG - www.avg.com
Version: 2013.0.3343 / Virus Database: 3199/6397 - Release Date: 06/09/13


Media Matrix Xfram88

 

Good Day,

Need Help in Controlling media matrix x-frame 88.
Just a sample code or module.

Really need to control media matrix xframe
Thanks in Advance.


Kenneth


Re: Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm

Chip
 

What devices do you have configured in your program on the Ethernet interface?

- Chip

--- In Crestron@..., "xymox1357" <public2@...> wrote:

Im seeing these once a minute in the log and im not sure whats causing them

--- In Crestron@..., "xymox1357" <public2@> wrote:


I am seeing a lot of these errors in my log. What does this mean ? They seem to occur about once a minute. Very annoying.

Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm for Console Sockets.


Re: Launching Sonos App from inside Mobile

 

Not likely to happen. So os doesn't want to add it to their app. I asked and was told they thought it was a security risk. rollseyes :

Sent from my pocket computer


Re: c# development

 

Foo,

I was referring to SIMPL# Pro which is not yet released.
On 2013-06-10, at 5:15 PM, "RobK" <fooguy89@...> wrote:

Neil,

OP is trying to do C# from his computer, you'll notice he's trying to create a viewport (toolbox) session to upload files. Not on a controller.

Also... SIMPL# - the ability to write libraries in C# and call them from your SIMPL+ modules - is released. It's not in beta.

--- In Crestron@..., Neil Dorin <neildorin@...> wrote:

You need to check on creatronlabs.com

Full c# programming is very much in beta still

Sent from my iPhone

On 2013-06-10, at 4:45 PM, Bradley Seman <el_perro_azul@...> wrote:

I did a search for c# in the Crestron group and it returned no results. Maybe i'm doing it wrong, but i'm new here.

We are trying to write a program in c# and part of the functionality needed to for it to be able to connect to a DMPS or MC2E and upload a new program for it and it's connected touch panel.

Our attempts at connecting to a device on the local network have not been successful.

The code we have been using is this (this is just test code, the actual code will use variable names instead of hard coded info):

VptSessionset = newVptSession();

private void btn_Load_Click(object sender, EventArgs e)
{
DialogResult result;
Form LoadForm = new LoadForm(listboxLoadList,
txtControlPanel.Text, txtTPProgram.Text, txtWebInterface.Text,
txtControlFirmware.Text, txtTPFirmware.Text);
result = LoadForm.ShowDialog();
if (result == System.Windows.Forms.DialogResult.OK)
{
//Here is
where we load the list
Console.WriteLine("New VtpSession created!");
set.OpenSession("tcp
10.25.146.126", "C# test");
Console.WriteLine("Session opened!");
int TransID = 0;
String program = ;//fill in your own path/file here
set.AsyncActivateStr(0, program, 10000, TransID, 0, 0);
Console.WriteLine("Session program send!");
}
else if (result ==
System.Windows.Forms.DialogResult.Cancel)
{
// Don't load the list
;
}
}
The program string is blank since you guys will have a different file and directory to use.

after this function is called the set_OnActivateStrComplete function is called:
private void set_OnActivateStrComplete(int nTransactionID, int nAbilityCode, byte bSuccess, string pszOutputs, int nUserPassBack)
{
Console.WriteLine("Inside
of the complete!");
Console.WriteLine(bSuccess);
Console.WriteLine(pszOutputs);
}

when bSuccess is output to the Console, a zero is printed, indicating failure.
does anyone have any suggestions?

[Non-text portions of this message have been removed]


[Non-text portions of this message have been removed]

[Non-text portions of this message have been removed]


Re: c# development

 

I believe your best bet is to get an MSDN subscription.

--- In Crestron@..., Eric Williams <ewilliams0305@...> wrote:

Where are people purchasing vs 2008 pro from. I'm finding nothing but shady looking resources (old software). I'm not seeing it on Microsoft. I've been told that vs 2012 pro would include down grade rites?

-----Original Message-----
From: "Neil Dorin" <neildorin@...>
Sent: �6/�10/�2013 6:55 PM
To: "Crestron@..." <Crestron@...>
Subject: Re: [Crestron] c# development


You need to check on creatronlabs.com

Full c# programming is very much in beta still

Sent from my iPhone

On 2013-06-10, at 4:45 PM, Bradley Seman <el_perro_azul@...> wrote:

I did a search for c# in the Crestron group and it returned no results. Maybe i'm doing it wrong, but i'm new here.

We are trying to write a program in c# and part of the functionality needed to for it to be able to connect to a DMPS or MC2E and upload a new program for it and it's connected touch panel.

Our attempts at connecting to a device on the local network have not been successful.

The code we have been using is this (this is just test code, the actual code will use variable names instead of hard coded info):

VptSessionset = newVptSession();

private void btn_Load_Click(object sender, EventArgs e)
{
DialogResult result;
Form LoadForm = new LoadForm(listboxLoadList,
txtControlPanel.Text, txtTPProgram.Text, txtWebInterface.Text,
txtControlFirmware.Text, txtTPFirmware.Text);
result = LoadForm.ShowDialog();
if (result == System.Windows.Forms.DialogResult.OK)
{
//Here is
where we load the list
Console.WriteLine("New VtpSession created!");
set.OpenSession("tcp
10.25.146.126", "C# test");
Console.WriteLine("Session opened!");
int TransID = 0;
String program = ;//fill in your own path/file here
set.AsyncActivateStr(0, program, 10000, TransID, 0, 0);
Console.WriteLine("Session program send!");
}
else if (result ==
System.Windows.Forms.DialogResult.Cancel)
{
// Don't load the list
;
}
}
The program string is blank since you guys will have a different file and directory to use.

after this function is called the set_OnActivateStrComplete function is called:
private void set_OnActivateStrComplete(int nTransactionID, int nAbilityCode, byte bSuccess, string pszOutputs, int nUserPassBack)
{
Console.WriteLine("Inside
of the complete!");
Console.WriteLine(bSuccess);
Console.WriteLine(pszOutputs);
}

when bSuccess is output to the Console, a zero is printed, indicating failure.
does anyone have any suggestions?

[Non-text portions of this message have been removed]

[Non-text portions of this message have been removed]




[Non-text portions of this message have been removed]


Re: c# development

Eric Williams
 

Where are people purchasing vs 2008 pro from. I'm finding nothing but shady looking resources (old software). I'm not seeing it on Microsoft. I've been told that vs 2012 pro would include down grade rites?

-----Original Message-----
From: "Neil Dorin" <neildorin@...>
Sent: �6/�10/�2013 6:55 PM
To: "Crestron@..." <Crestron@...>
Subject: Re: [Crestron] c# development


You need to check on creatronlabs.com

Full c# programming is very much in beta still
On 2013-06-10, at 4:45 PM, Bradley Seman <el_perro_azul@...> wrote:

I did a search for c# in the Crestron group and it returned no results. Maybe i'm doing it wrong, but i'm new here.

We are trying to write a program in c# and part of the functionality needed to for it to be able to connect to a DMPS or MC2E and upload a new program for it and it's connected touch panel.

Our attempts at connecting to a device on the local network have not been successful.

The code we have been using is this (this is just test code, the actual code will use variable names instead of hard coded info):

VptSessionset = newVptSession();

private void btn_Load_Click(object sender, EventArgs e)
{
DialogResult result;
Form LoadForm = new LoadForm(listboxLoadList,
txtControlPanel.Text, txtTPProgram.Text, txtWebInterface.Text,
txtControlFirmware.Text, txtTPFirmware.Text);
result = LoadForm.ShowDialog();
if (result == System.Windows.Forms.DialogResult.OK)
{
//Here is
where we load the list
Console.WriteLine("New VtpSession created!");
set.OpenSession("tcp
10.25.146.126", "C# test");
Console.WriteLine("Session opened!");
int TransID = 0;
String program = ;//fill in your own path/file here
set.AsyncActivateStr(0, program, 10000, TransID, 0, 0);
Console.WriteLine("Session program send!");
}
else if (result ==
System.Windows.Forms.DialogResult.Cancel)
{
// Don't load the list
;
}
}
The program string is blank since you guys will have a different file and directory to use.

after this function is called the set_OnActivateStrComplete function is called:
private void set_OnActivateStrComplete(int nTransactionID, int nAbilityCode, byte bSuccess, string pszOutputs, int nUserPassBack)
{
Console.WriteLine("Inside
of the complete!");
Console.WriteLine(bSuccess);
Console.WriteLine(pszOutputs);
}

when bSuccess is output to the Console, a zero is printed, indicating failure.
does anyone have any suggestions?

[Non-text portions of this message have been removed]






[Non-text portions of this message have been removed]


Re: Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm

 

Im seeing these once a minute in the log and im not sure whats causing them

--- In Crestron@..., "xymox1357" <public2@...> wrote:


I am seeing a lot of these errors in my log. What does this mean ? They seem to occur about once a minute. Very annoying.

Error: CConsoleListenSocket::AcceptConnection: unable to disable Nagle algorithm for Console Sockets.


Re: Device Firmware

 

4.003.0015 is the latest released firmware for MP2E and QM-RMC style processors.

But yes, it is indeed lagging behind the rest of the 2 series so you might want to see if you need a beta firmware for your processor depending on what you're trying to do.

--- In Crestron@..., Heather Baiman <heather@...> wrote:

4.003.0015 is not the latest firmware for the 2-series.

Most programs don't need to upgrade beyond this version unless you're doing stuff with Smart Graphics I think.
________________________________________
From: Crestron@... [Crestron@...] on behalf of Sebastian [s.marszalek11@...]
Sent: Monday, June 10, 2013 7:36 PM
To: Crestron@...
Subject: [Crestron] Device Firmware

Hey All,

I keep getting this message when I upload a program to a processor.

" The device firmware does not meet the minimum requirements of the File.

Device:4.003.0015(Oct 04 2010)
File:4.006"

This is the latest firmware for the device, anyone know why it's asking that?