Looking for Leads on a New Gig
Hello Group,
I find myself thrust into the unfortunate state of no income stream :( So, I am looking for a new gig. If anyone knows of an available position, please let me know. I am currently looking in the Seattle, Denver or Dallas areas, but will consider other locations as well. Me: Silver Master (Gold after one more Masters class), AMX ACE Design/Programming (expired) with 20+ years in Crestron & AMX programming in commercial and residential markets. Any leads would be greatly appreciated. erik |
Re: Lutron QS Request Command <--Please someone help!!
Eric Williams
Its been a while but instead of "1" try the commands using "ALL_DEVICES" as your integration Id. It will definitely work for polling not sure about setting levels.
toggle quoted message
Show quoted text
-----Original Message-----
From: "sevenstarokawari" <tabata@...> Sent: ?3/?21/?2013 9:09 PM To: "Crestron@..." <Crestron@...> Subject: [Crestron] Re: Lutron QS Request Command <--Please someone help!! --- In Crestron@..., "sevenstarokawari" <tabata@...> wrote:
[Non-text portions of this message have been removed] |
Re: Lutron QS Request Command <--Please someone help!!
--- In Crestron@..., "sevenstarokawari" <tabata@...> wrote:
|
Re: Infinet EX Switch and 1 HP Motor
Pay attention to the minimum load...
toggle quoted message
Show quoted text
JRW --- In Crestron@..., "jac777888" <jchelton@...> wrote:
|
Re: Infinet EX Switch and 1 HP Motor
Great thats what I though, I knew the RadioRA switches had a minimum load, so wasnt sure if the same applied to the EX switches (first time using them).
toggle quoted message
Show quoted text
--- In Crestron@..., "seb_mtl" <seb514mtl@...> wrote:
|
Re: Infinet EX Switch and 1 HP Motor
a switch is a switch
toggle quoted message
Show quoted text
you can control a 120v coil relay who control another bigger relay. you can control a power plant if you want just , you need.... neutral ( the white one ) --- In Crestron@..., "jac777888" <jchelton@...> wrote:
|
Infinet EX Switch and 1 HP Motor
Hi,
I am trying to control a pool pump motor and notice the size limit for motors for the CLW-SWEX-P is 1/2 HP and pump is 1HP. My question is has anyone used or forsee any problems using a CLW-SWEX-P to activate a contactor like a Fuji SC-E1 that has a 120V coil? Thanks |
Re: Bacnet Comms with Honeywell hawk centraline. S/w coach ax
since march 3 2013 , the priority is managed in Crestron bacnet subsystem
toggle quoted message
Show quoted text
just tried today with latest database AND cp3 and it's working --- In Crestron@..., "Alessandro Maldini" <alessandro.maldini@...> wrote:
|
Re: symetrix jupiter 8 series
I made 6 or 7 big restaurants ( 350 people ) with that
toggle quoted message
Show quoted text
what do you want to know ? --- In Crestron@..., "Daniel Fattorini" <dan@...> wrote:
|
Re: subpage z-order ft-tps4
Been there, done that... The flip-top simply doesn't have that option. Which tells me that probably a separate team of engineers worked on the flip top model than the 4L. Other than that, I can't imagine why the hardware would be different between the two models.
toggle quoted message
Show quoted text
Weak... The last triggered subpage is what always shows up. You will have to do some tricks with delayed pulses or something... Fabio --- In Crestron@..., "jaaronart" <jaaron7@...> wrote:
|
Re: symetrix jupiter 8 series
Daniel Fattorini
There's a standard one out there (CresDB I think) but be warned: Symetrix stuff is odd. Last time I did one it had a very strange characteristic. It only responded to serial commands via the 232 port if it was connected to a network via the LAN. Pull out the LAN cable and wham: "err\x0D" to all commands. They said its a bug but a damn nasty one if you ask me. Ended up leaving my cheap 4 port switch in the back of it just to keep it working.
toggle quoted message
Show quoted text
--- In Crestron@..., "raid shamsa" <raidshamsa@...> wrote:
|
Re: Roomview Enabled Display Stupidity
@Jeremy
toggle quoted message
Show quoted text
In fairness to Vivitek, that issue was a Crestron issue, fixed in a SIMPL update (IIRC) about six months ago. It didn't affect just Vivitek, I believe BenQ and others were affected. And yes, increasing numbers of projectors are turning comms off by default when in standby to meet green star requirements. I had a job recently where we had to jump through hoops to get an Epson to play ball once it was placed in standby (something about Communications On in one of the sub menus...). Phil. --- In Crestron@..., Jeremy Weatherford <jweather@...> wrote:
|
D3 "link" levels between two switches
Heath Volmer
Is there any way to make one load's level always match another?
I have a case where a slave switch needs to turn on it's load, as well as an adjacent load. I thought there was a way to say "level1 = level2". Alternatively, is there a way to somehow respond to the slave button programmatically? I can't see anything, even at the simpl level. Might have to pull this slave out and stick in a keypad or dummy dimmer. Heath Volmer Digital Domain Systems Littleton, CO |
subpage z-order ft-tps4
Does the flip-top TPS4 not have the option for sub-page z-order? I've always preferred the option for "Follow subpage-reference Z-order" for my projects, so I can always be sure of how the subpages will display. The C2N-FT-TPS4 doesn't have that Compile option, but the TPS4L does.
I can't recall if the option was there before and has disappeared or if I'm just thinking of other touchpanels that I've used. Can someone confirm if this option was ever available for the ft-tps4? I just updated everything with Master Installer last night, so I'm wondering if a recent update may have done away with it. |
Re: On site with unfamiliar Denon Receiver
After a quick glance at the API, it appears to be using pretty standard
Denon AVR commands, so I would assume most any modern Denon AVR module would work. . .at least for core features like power, volume, input, etc. From: Crestron@... [mailto:Crestron@...] On Behalf Of Audible Solutions Sent: Thursday, March 21, 2013 6:35 PM To: Crestron@... Subject: [Crestron] On site with unfamiliar Denon Receiver On Commercial job with a Denon DN-500AV receiver. Not familiar with this unit and curious if anyone know if any existing module(s), and if so which, work with this unit? TIA Alan |
Re: Roomview Enabled Display Stupidity
Yeah, they just use the DB15 connector instead.... :)
toggle quoted message
Show quoted text
--- In Crestron@..., Jeremy Weatherford <jweather@...> wrote:
|
Re: Roomview Enabled Display Stupidity
My favorite is the Vivitek projectors that will select any input via the
toggle quoted message
Show quoted text
"RoomView Display" control module except for VGA. Nobody uses that anymore anyway... On Thu, Mar 21, 2013 at 3:25 PM, codinsorian <codinsorian@...> wrote:
I particularly enjoy the Epson projectors we purchased that is Roomview --
Jeremy Weatherford |
Re: Roomview Enabled Display Stupidity
There is a setting for Epson projectors to leave comm's enabled when the projector is off. Menu > Extended > Standby Mode > Communications On
toggle quoted message
Show quoted text
--- In Crestron@..., "codinsorian" <codinsorian@...> wrote:
|
to navigate to use esc to dismiss