Hello Group,

I find myself thrust into the unfortunate state of no income stream :(

So, I am looking for a new gig. If anyone knows of an available position, please let me know. I am currently looking in the Seattle, Denver or Dallas areas, but will consider other locations as well.

Me: Silver Master (Gold after one more Masters class), AMX ACE Design/Programming (expired) with 20+ years in Crestron & AMX programming in commercial and residential markets.

Any leads would be greatly appreciated.

erik


Re: Lutron QS Request Command <--Please someone help!!

Eric Williams
 

Its been a while but instead of "1" try the commands using "ALL_DEVICES" as your integration Id. It will definitely work for polling not sure about setting levels.

-----Original Message-----
From: "sevenstarokawari" <tabata@...>
Sent: ?3/?21/?2013 9:09 PM
To: "Crestron@..." <Crestron@...>
Subject: [Crestron] Re: Lutron QS Request Command <--Please someone help!!




--- In Crestron@..., "sevenstarokawari" <tabata@...> wrote:

Would someone advise me the command to get all zone's brightness of Lutron QS simultaneously?
Actually I sent"?OUTPUT,1,1<CR><LF>", but nothing happens.
The Lutron QS ID of mine is "1"


Regards,



[Non-text portions of this message have been removed]


Re: Lutron QS Request Command <--Please someone help!!

 

--- In Crestron@..., "sevenstarokawari" <tabata@...> wrote:

Would someone advise me the command to get all zone's brightness of Lutron QS simultaneously?
Actually I sent"?OUTPUT,1,1<CR><LF>", but nothing happens.
The Lutron QS ID of mine is "1"


Regards,


Re: Infinet EX Switch and 1 HP Motor

 

Pay attention to the minimum load...

JRW

--- In Crestron@..., "jac777888" <jchelton@...> wrote:

Great thats what I though, I knew the RadioRA switches had a minimum load, so wasnt sure if the same applied to the EX switches (first time using them).

--- In Crestron@..., "seb_mtl" <seb514mtl@> wrote:


a switch is a switch

you can control a 120v coil relay who control another bigger relay.

you can control a power plant if you want


just , you need.... neutral ( the white one )





--- In Crestron@..., "jac777888" <jchelton@> wrote:

Hi,

I am trying to control a pool pump motor and notice the size limit for motors for the CLW-SWEX-P is 1/2 HP and pump is 1HP.

My question is has anyone used or forsee any problems using a CLW-SWEX-P to activate a contactor like a Fuji SC-E1 that has a 120V coil?

Thanks


Re: Infinet EX Switch and 1 HP Motor

 

Great thats what I though, I knew the RadioRA switches had a minimum load, so wasnt sure if the same applied to the EX switches (first time using them).

--- In Crestron@..., "seb_mtl" <seb514mtl@...> wrote:


a switch is a switch

you can control a 120v coil relay who control another bigger relay.

you can control a power plant if you want


just , you need.... neutral ( the white one )





--- In Crestron@..., "jac777888" <jchelton@> wrote:

Hi,

I am trying to control a pool pump motor and notice the size limit for motors for the CLW-SWEX-P is 1/2 HP and pump is 1HP.

My question is has anyone used or forsee any problems using a CLW-SWEX-P to activate a contactor like a Fuji SC-E1 that has a 120V coil?

Thanks


Re: Infinet EX Switch and 1 HP Motor

 

a switch is a switch

you can control a 120v coil relay who control another bigger relay.

you can control a power plant if you want


just , you need.... neutral ( the white one )

--- In Crestron@..., "jac777888" <jchelton@...> wrote:

Hi,

I am trying to control a pool pump motor and notice the size limit for motors for the CLW-SWEX-P is 1/2 HP and pump is 1HP.

My question is has anyone used or forsee any problems using a CLW-SWEX-P to activate a contactor like a Fuji SC-E1 that has a 120V coil?

Thanks


Infinet EX Switch and 1 HP Motor

 

Hi,

I am trying to control a pool pump motor and notice the size limit for motors for the CLW-SWEX-P is 1/2 HP and pump is 1HP.

My question is has anyone used or forsee any problems using a CLW-SWEX-P to activate a contactor like a Fuji SC-E1 that has a 120V coil?

Thanks


Re: Bacnet Comms with Honeywell hawk centraline. S/w coach ax

 

since march 3 2013 , the priority is managed in Crestron bacnet subsystem

just tried today with latest database AND cp3
and it's working

--- In Crestron@..., "Alessandro Maldini" <alessandro.maldini@...> wrote:

Hi Matt,
beware of the fact that Crestron processor doesn?€?t handle the ?€?priority array?€? of BACnet IP protocol ; when the processor writes a BACnet object, it always does it with ?€?Priority 1?€? (probably highest than that used by the Honeywell control unit).

Alessandro

From: Neil Dorin
Sent: Thursday, December 13, 2012 2:41 PM
To: Crestron@...
Subject: Re: [Crestron] Bacnet Comms with Honeywell hawk centraline. S/w coach ax


BACnet uses UDP communication so there's no need to specify an IP address.

You'll need to have unique IDs assigned for the Crestron processor and the HVAC device you're talking to. It doesn't matter what ID you use as long as they're separate.

Probably the easiest way to handle HVAC control is to use an analog value to send to the HVAC system to request a set point, then the HVAC programmer supplies you with an analog input (input to his system) that will represent the current temp read by his sensor(s).

This way you only need 2 BACnet points per HVAC zone. Add the two for your processor as a device and his HVAC controller you're at 4 points for a single zone, plus 2 points for each additional. Under 50 points can be done with the free license in a 3-series processor.

-Neil Dorin

Sent from my iPhone

On 2012-12-13, at 1:31 AM, "mattstrads" <mailto:matt.stradling%40dawsonsav.co.uk> wrote:

Has anyone got any experience controlling this system over bacnet?
The hvac programmer hasn't done this before and needs to create backet points according to crestron. How can they do this?

Also in the crestron remote bacnet modules there seems to be nowhere to enter the remote IP address, only the name, id and port. Is this all the crestron needs? We did get some feedback about the remote device.

Any tips would be appreciated
Many thanks

Matt






Nessun virus nel messaggio.
Controllato da AVG - www.avg.com
Versione: 2013.0.2805 / Database dei virus: 2634/5953 - Data di rilascio: 12/12/2012




Re: symetrix jupiter 8 series

 

I made 6 or 7 big restaurants ( 350 people ) with that

what do you want to know ?

--- In Crestron@..., "Daniel Fattorini" <dan@...> wrote:

There's a standard one out there (CresDB I think) but be warned: Symetrix stuff is odd. Last time I did one it had a very strange characteristic. It only responded to serial commands via the 232 port if it was connected to a network via the LAN. Pull out the LAN cable and wham: "err&#92;x0D" to all commands. They said its a bug but a damn nasty one if you ask me. Ended up leaving my cheap 4 port switch in the back of it just to keep it working.

--- In Crestron@..., "raid shamsa" <raidshamsa@> wrote:

hi

does any one have a moduel to control a jupitor syries audio switcher from symetrics. will be willing to pay if need be

thanks




Re: subpage z-order ft-tps4

 

Been there, done that... The flip-top simply doesn't have that option. Which tells me that probably a separate team of engineers worked on the flip top model than the 4L. Other than that, I can't imagine why the hardware would be different between the two models.

Weak...

The last triggered subpage is what always shows up. You will have to do some tricks with delayed pulses or something...
Fabio

--- In Crestron@..., "jaaronart" <jaaron7@...> wrote:

Does the flip-top TPS4 not have the option for sub-page z-order? I've always preferred the option for "Follow subpage-reference Z-order" for my projects, so I can always be sure of how the subpages will display. The C2N-FT-TPS4 doesn't have that Compile option, but the TPS4L does.

I can't recall if the option was there before and has disappeared or if I'm just thinking of other touchpanels that I've used.

Can someone confirm if this option was ever available for the ft-tps4?

I just updated everything with Master Installer last night, so I'm wondering if a recent update may have done away with it.


Re: symetrix jupiter 8 series

Daniel Fattorini
 

There's a standard one out there (CresDB I think) but be warned: Symetrix stuff is odd. Last time I did one it had a very strange characteristic. It only responded to serial commands via the 232 port if it was connected to a network via the LAN. Pull out the LAN cable and wham: "err&#92;x0D" to all commands. They said its a bug but a damn nasty one if you ask me. Ended up leaving my cheap 4 port switch in the back of it just to keep it working.

--- In Crestron@..., "raid shamsa" <raidshamsa@...> wrote:

hi

does any one have a moduel to control a jupitor syries audio switcher from symetrics. will be willing to pay if need be

thanks




Re: Roomview Enabled Display Stupidity

 

@Jeremy

In fairness to Vivitek, that issue was a Crestron issue, fixed in a SIMPL update (IIRC) about six months ago. It didn't affect just Vivitek, I believe BenQ and others were affected.

And yes, increasing numbers of projectors are turning comms off by default when in standby to meet green star requirements. I had a job recently where we had to jump through hoops to get an Epson to play ball once it was placed in standby (something about Communications On in one of the sub menus...).

Phil.

--- In Crestron@..., Jeremy Weatherford <jweather@...> wrote:

My favorite is the Vivitek projectors that will select any input via the
"RoomView Display" control module except for VGA. Nobody uses that anymore
anyway...


On Thu, Mar 21, 2013 at 3:25 PM, codinsorian <codinsorian@...> wrote:

I particularly enjoy the Epson projectors we purchased that is Roomview
compliant that does not work with....Roomview Enterprise.

Throughly enjoyed that one.

- Dan

--- In Crestron@..., Eric Walters <sentry07@> wrote:

Whyyyyyyyyyyyyyyyyyyyyyy why why why why would a manufacturer put
Roomview
stuff in their projectors and then turn off the web/roomview interface
when
you turn off the projector? Unless I'm being extremely stupid here, and
not
seeing the option to disable this, I don't get it. Turn the projector on
with the remote and the roomview stuff works, turn the projector off with
roomview and now none of the roomview stuff works and the projector won't
turn on.

WHY?! Tell me I'm not alone on this one, please.


[Non-text portions of this message have been removed]



------------------------------------




Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the
Database area.
Yahoo!
Groups Links




--
Jeremy Weatherford




D3 "link" levels between two switches

Heath Volmer
 

Is there any way to make one load's level always match another?

I have a case where a slave switch needs to turn on it's load, as well as an adjacent load. I thought there was a way to say "level1 = level2".

Alternatively, is there a way to somehow respond to the slave button programmatically? I can't see anything, even at the simpl level. Might have to pull this slave out and stick in a keypad or dummy dimmer.

Heath Volmer
Digital Domain Systems
Littleton, CO


subpage z-order ft-tps4

 

Does the flip-top TPS4 not have the option for sub-page z-order? I've always preferred the option for "Follow subpage-reference Z-order" for my projects, so I can always be sure of how the subpages will display. The C2N-FT-TPS4 doesn't have that Compile option, but the TPS4L does.

I can't recall if the option was there before and has disappeared or if I'm just thinking of other touchpanels that I've used.

Can someone confirm if this option was ever available for the ft-tps4?

I just updated everything with Master Installer last night, so I'm wondering if a recent update may have done away with it.


Re: On site with unfamiliar Denon Receiver

 

After a quick glance at the API, it appears to be using pretty standard
Denon AVR commands, so I would assume most any modern Denon AVR module would
work. . .at least for core features like power, volume, input, etc.



From: Crestron@... [mailto:Crestron@...] On Behalf
Of Audible Solutions
Sent: Thursday, March 21, 2013 6:35 PM
To: Crestron@...
Subject: [Crestron] On site with unfamiliar Denon Receiver





On Commercial job with a Denon DN-500AV receiver. Not familiar with this
unit and curious if anyone know if any existing module(s), and if so which,
work with this unit?

TIA

Alan


On site with unfamiliar Denon Receiver

 

On Commercial job with a Denon DN-500AV receiver. Not familiar with this unit and curious if anyone know if any existing module(s), and if so which, work with this unit?

TIA

Alan


Re: Roomview Enabled Display Stupidity

 

Yeah, they just use the DB15 connector instead.... :)

--- In Crestron@..., Jeremy Weatherford <jweather@...> wrote:

My favorite is the Vivitek projectors that will select any input via the
"RoomView Display" control module except for VGA. Nobody uses that anymore
anyway...


On Thu, Mar 21, 2013 at 3:25 PM, codinsorian <codinsorian@...> wrote:

I particularly enjoy the Epson projectors we purchased that is Roomview
compliant that does not work with....Roomview Enterprise.

Throughly enjoyed that one.

- Dan

--- In Crestron@..., Eric Walters <sentry07@> wrote:

Whyyyyyyyyyyyyyyyyyyyyyy why why why why would a manufacturer put
Roomview
stuff in their projectors and then turn off the web/roomview interface
when
you turn off the projector? Unless I'm being extremely stupid here, and
not
seeing the option to disable this, I don't get it. Turn the projector on
with the remote and the roomview stuff works, turn the projector off with
roomview and now none of the roomview stuff works and the projector won't
turn on.

WHY?! Tell me I'm not alone on this one, please.


[Non-text portions of this message have been removed]



------------------------------------




Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the
Database area.
Yahoo!
Groups Links




--
Jeremy Weatherford




Re: Roomview Enabled Display Stupidity

 

My favorite is the Vivitek projectors that will select any input via the
"RoomView Display" control module except for VGA. Nobody uses that anymore
anyway...

On Thu, Mar 21, 2013 at 3:25 PM, codinsorian <codinsorian@...> wrote:

I particularly enjoy the Epson projectors we purchased that is Roomview
compliant that does not work with....Roomview Enterprise.

Throughly enjoyed that one.

- Dan

--- In Crestron@..., Eric Walters <sentry07@...> wrote:

Whyyyyyyyyyyyyyyyyyyyyyy why why why why would a manufacturer put
Roomview
stuff in their projectors and then turn off the web/roomview interface
when
you turn off the projector? Unless I'm being extremely stupid here, and
not
seeing the option to disable this, I don't get it. Turn the projector on
with the remote and the roomview stuff works, turn the projector off with
roomview and now none of the roomview stuff works and the projector won't
turn on.

WHY?! Tell me I'm not alone on this one, please.






------------------------------------




Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the
Database area.
Yahoo!
Groups Links


--
Jeremy Weatherford


symetrix jupiter 8 series

 

hi

does any one have a moduel to control a jupitor syries audio switcher from symetrics. will be willing to pay if need be

thanks



Re: Roomview Enabled Display Stupidity

 

There is a setting for Epson projectors to leave comm's enabled when the projector is off. Menu > Extended > Standby Mode > Communications On

--- In Crestron@..., "codinsorian" <codinsorian@...> wrote:

I particularly enjoy the Epson projectors we purchased that is Roomview compliant that does not work with....Roomview Enterprise.

Throughly enjoyed that one.

- Dan

--- In Crestron@..., Eric Walters <sentry07@> wrote:

Whyyyyyyyyyyyyyyyyyyyyyy why why why why would a manufacturer put Roomview
stuff in their projectors and then turn off the web/roomview interface when
you turn off the projector? Unless I'm being extremely stupid here, and not
seeing the option to disable this, I don't get it. Turn the projector on
with the remote and the roomview stuff works, turn the projector off with
roomview and now none of the roomview stuff works and the projector won't
turn on.

WHY?! Tell me I'm not alone on this one, please.