Mag322 (Infomir) STB?IR?code ?

 

Hi

Looking for some IR captures of remote of Infomir STB (more specifically MAG322) although it looks to be same remote for all models. I found out an IP protocol but it looks quite cumbersome to get simple commands control. Someone got experiences with these ? or IR capture of the remote ?

Thanks

³Õ¾±²Ô³¦¨¨²Ô


Re: S# Pro on RMC4 with a DM-XIO-DIR #rmc4

 

Are you familiar with Answer ID?1000315?? Even with less than 65 endpoints defined, I have still seen similar issues with overloading the processor - I would recommend trying the commands in that section to see if it improves things.


On Thu, May 26, 2022 at 11:45 AM Mark via <junkmailhangar=[email protected]> wrote:
I have a program that defines a director, four NVX units, adds them to the unit and then registers the lot. I receive very odd messaging in the error log and am not sure where to begin looking. Another odd behavior is attempting to stop the program takes a very long time. Has anyone seen this before:


? 408. Error: SimplSharpPro[App01] # 2022-05-26 10:14:39 # ?Unable to post message to queue for Device ID DC for parent Type DEVICE_PARENT_ETHERNET_TYPE: IP-ID-DC
? 409. Error: CIPCommandProcessor # 2022-05-26 10:14:39 # ?SendDataToSocket: Send failed with error code 10058
? 410. Error: SimplSharpPro[App01] # 2022-05-26 10:14:59 # ?Unable to post message to queue for Device ID DC for parent Type DEVICE_PARENT_ETHERNET_TYPE: IP-ID-DC
? 411. Notice: TLDM # 2022-05-26 10:15:08 # WriteUnixDomainSocket: len=32 pid=3524; Thread 3539; timeout 20000; SO_SNDBUF 4196000 (tick end 77374425: start 77352881: delta 21544) maxMsg 4196; sendto /dev/shm/rqueue/SEND_1_QUEUE/0008469 error Resource temporarily unavailable(11)
? 412. Error: TLDM # 2022-05-26 10:15:08 # SendMessageToQueue : Unable to send message to queue App1Queue. Error Code 0xb
? 413. Error: SimplSharpPro[App01] # 2022-05-26 10:15:19 # ?Unable to post message to queue for Device ID DC for parent Type DEVICE_PARENT_ETHERNET_TYPE: IP-ID-DC
? 414. Notice: TLDM # 2022-05-26 10:15:28 # WriteUnixDomainSocket: len=76 pid=3524; Thread 3539; timeout 20000; SO_SNDBUF 4196000 (tick end 77394909: start 77374425: delta 20484) maxMsg 4196; sendto /dev/shm/rqueue/SEND_1_QUEUE/0008469 error Resource temporarily unavailable(11)
? 415. Error: TLDM # 2022-05-26 10:15:28 # SendMessageToQueue : Unable to send message to queue App1Queue. Error Code 0xb
? 416. Error: SimplSharpPro[App01] # 2022-05-26 10:15:39 # ?Unable to post message to queue for Device ID DC for parent Type DEVICE_PARENT_ETHERNET_TYPE: IP-ID-DC
? 417. Error: SimplSharpPro[App01] # 2022-05-26 10:15:59 # ?Unable to post message to queue for Device ID DC for parent Type DEVICE_PARENT_ETHERNET_TYPE: IP-ID-DC
? 418. Error: CIPCommandProcessor # 2022-05-26 10:16:14 # ?SendDataToSocket: Send failed with error code 10058
? 419. Error: SimplSharpPro[App01] # 2022-05-26 10:16:19 # ?Unable to post message to queue for Device ID DC for parent Type DEVICE_PARENT_ETHERNET_TYPE: IP-ID-DC
?


Re: 70 series VTP default page when processor offline

 

To find the reserved join, instead of typing a join number into the property box in VTP, use the drop-down beside it and select the function you want.
--
Josh Winn
The LiquidPixel Group


Re: SW-VMK-WIN

 

¿ªÔÆÌåÓý

Yeah, i think it?s similar to EventGhost which i?ve used in the past.

I was just thinking using the Crestron tool would be easier to interface as there are already drivers in SIMPL, but if the tool isn?t working, that?s not helping.

?

@Chris
I?m not familiar with MCE, but EventGhost () is bidirectional and can trigger events to the outside world.

?

Cheers,

Thorsten

?

Von: [email protected] <[email protected]> Im Auftrag von Geoffrey Reynolds
Gesendet: Montag, 30. Mai 2022 22:50
An: [email protected]
Betreff: Re: [crestron] SW-VMK-WIN

?

MCE Controller works really well:

?

?

Pair it with a TCP Client symbol in your SIMPL program and you're good to go.? I've been using it for years without any issues.

?

Geoff

?

On Mon, May 30, 2022 at 4:09 PM Thorsten K?hler <thorsten.koehler@...> wrote:

Hi,

?

i need to control a Windows 10 PC from a Crestron touchpanel and wanted to give the VMK-WIN a try.

It installs fine and the service is running, but it doesn?t seem to work correctly. For instance the Crestron symbol that should appear in the system tray after reboot is missing.

Any ideas or is this tool just too old for Windows 10/11?

?

Cheers,

Thorsten


Re: SW-VMK-WIN

 

If you¡¯re asking about MCE controller, I think so, but I have only used it to initiate actions on the PC from the Crestron side.

Geoff

On Mon, May 30, 2022 at 7:55 PM ckangis <chris@...> wrote:
Just curious,
Can you have the PC control Crestron also??? i.e. is it bi-directional??


Re: SW-VMK-WIN

 

Just curious,
Can you have the PC control Crestron also??? i.e. is it bi-directional??


Re: SW-VMK-WIN

 

MCE Controller works really well:


Pair it with a TCP Client symbol in your SIMPL program and you're good to go.? I've been using it for years without any issues.

Geoff


On Mon, May 30, 2022 at 4:09 PM Thorsten K?hler <thorsten.koehler@...> wrote:

Hi,

?

i need to control a Windows 10 PC from a Crestron touchpanel and wanted to give the VMK-WIN a try.

It installs fine and the service is running, but it doesn?t seem to work correctly. For instance the Crestron symbol that should appear in the system tray after reboot is missing.

Any ideas or is this tool just too old for Windows 10/11?

?

Cheers,

Thorsten


Re: 70 series VTP default page when processor offline

 

What Phil said


SW-VMK-WIN

 

¿ªÔÆÌåÓý

Hi,

?

i need to control a Windows 10 PC from a Crestron touchpanel and wanted to give the VMK-WIN a try.

It installs fine and the service is running, but it doesn?t seem to work correctly. For instance the Crestron symbol that should appear in the system tray after reboot is missing.

Any ideas or is this tool just too old for Windows 10/11?

?

Cheers,

Thorsten


Re: 70 series VTP default page when processor offline

 

I'd do a modal subpage that is fed by the reserved join for panel offline.?


On Mon, May 30, 2022, 3:01 PM RK-X <rkx1984@...> wrote:
Bit of an embarrassing one here, You can display a page prior to processor online when panel boots (Page 1) *System startup, Please wait* I'm sure there was a way to display that page when the processor goes offline after successful System boot *System Failure - Call xxxxxx*

I normally wouldn't bother because fusion handles notifications for Support. This is a non fusion setup with an old fashioned email alert.

Did a test on a brand new panel and page 1 never shows when CP4's network is pulled.

Please someone jog my memory or tell me I dreamt it...


70 series VTP default page when processor offline

 

Bit of an embarrassing one here, You can display a page prior to processor online when panel boots (Page 1) *System startup, Please wait* I'm sure there was a way to display that page when the processor goes offline after successful System boot *System Failure - Call xxxxxx*

I normally wouldn't bother because fusion handles notifications for Support. This is a non fusion setup with an old fashioned email alert.

Did a test on a brand new panel and page 1 never shows when CP4's network is pulled.

Please someone jog my memory or tell me I dreamt it...


Re: Biamp Tesira X400 - VOIP dialer not controlled via Crestron

 

Contact biamp. They have a newer .clz that has to be added to the processor


Biamp Tesira X400 - VOIP dialer not controlled via Crestron

 

Good day all,?

Trying to control the VOIP dialer within a Tesira Forte X400 unit.?
The dialer from the DSP/Tesira software works.?
However, i cannot get the VOIP dialer to initialize with the 3.0 or 3.2 module versions.?

Leve/mute/state controls work well. Just the VOiP dialer does not work at all. If I set the Enable for VOIP low, then Command processor module init completes.?
I did confirm both VOIP instance names from the DSP file. Copied and pasted to be sure program tags match the DSP file.??

Any ideas of how to work around this??

Tesira Forte x 400
FW: 4.2.4.5

Thanks,?

Tray


#Biamp # DSP


Re: Launching a 3rd party app from the crestron go app #crestronapp

 

Hi Tony, i've only just started using shortcuts and they could be very handle. Shortcuts works like a command list or schedule list. A Shortcut can also adds a icon on the iphone home page. Basically you can use the shortcut to open one or more apps. Its a good workaround if you can't find or a app doesn't have a URL scheme.??


Re: File Loading

 

On Thu, May 26, 2022 at 02:36 PM, Mark wrote:
Take a look at answer ID?1000489.

100%.??

Toolbox automatically zips the .sig file to a .zig during program upload; you have to do that manually and push the .zig to \simpl\app##\.


Re: telnet control of DM-RMC scaler

 

I'm not sure about a DM-MD8x8 but I know in a DMPS3 you can pass telnet through the DMPS3 to the endpoint on certain ports.? Try doing a DUMPDMIPCONFIG?on the 8x8 and see if it gives you a table that looks something like this:

TableStart: DM IP Config

Slot# ? ? ? ? |Device_Name ? ? ? ? ? ? |FW_Version ? ? ?|Ext_IP_Address |TCP_Port|Int_IP_Address |LINK |MAG
-----------------------------------------------------------------------------------------------------------
8 ? ? ? ? ? ? |C2I-DMPS3-4K-AUDIO ? ? ?|1.3711.00005 ? ?|10.111.7.113 ? |50003 ? |169.254.0.3 ? ?|UP ? |N ?
9 ? ? ? ? ? ? |C2I-DMPS3-4K-350-VIDEO ?|1.3458.0033 ? ? |10.111.7.113 ? |50004 ? |169.254.0.4 ? ?|UP ? |N ?
9.1 ? ? ? ? ? |DMPS3-4K-300-HDMI-RX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ?
9.2 ? ? ? ? ? |DMPS3-4K-300-HDMI-RX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ?
9.3 ? ? ? ? ? |DMPS3-4K-300-HDMI-RX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ?
9.4 ? ? ? ? ? |DMPS3-4K-300-HDMI-RX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ?
9.5 ? ? ? ? ? |DMPS3-4K-300-HDMI-RX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ?
9.6 ? ? ? ? ? |DMPS3-4K-300-HDMI-RX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ?
9.7 ? ? ? ? ? |DMPS3-4K-300-DM-RX ? ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ?
9.8 ? ? ? ? ? |DMPS3-4K-300-DM-RX ? ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ?
9.9 ? ? ? ? ? |DMPS3-4K-STR ? ? ? ? ? ?|1.3459.00091 ? ?|10.111.7.113 ? |50009 ? |169.254.0.9 ? ?|UP ? |N ?
9.11 ? ? ? ? ?|DMPS3-4K-300-HDMI-TX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ?
9.12 ? ? ? ? ?|DMPS3-4K-300-HDMI-TX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ?
9.13 ? ? ? ? ?|DMPS3-4K-300-DM-TX ? ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ?
9.13.1 ? ? ? ?|DM-RMC-4KZ-SCALER-C ? ? |1.3991.00063 ? ?|10.111.7.113 ? |50007 ? |169.254.0.7 ? ?|UP ? |N ?
9.14 ? ? ? ? ?|DMPS3-4K-300-DM-TX ? ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ?
9.14.1 ? ? ? ?|DM-RMC-4KZ-SCALER-C ? ? |1.3991.00063 ? ?|10.111.7.113 ? |50008 ? |169.254.0.8 ? ?|UP ? |N??

What this means is if you telnet into the DMPS3-4k (10.111.7.113) on port 50007 or 50008, you will actually be telnetting into the scalers connected by DM.

On Thu, May 26, 2022 at 7:25 PM ebalsley via <ebalsley=[email protected]> wrote:
I'm building an external control system that will send simple commands to a Crestron DM using TCP (telnet) commands.? This works fine with the DM-MD8x8.? But I'm not sure how to switch inputs on the DM-RMC-4KZ-SCALER-C.? This device doesn't have a regular IP address because it receives its input from the DM over HDbaseT.? Is there some way to talk to this device through the network?


Re: Launching a 3rd party app from the crestron go app #crestronapp

 

Alex,
Does this still work with the ATV remote now that it is relegated to the Control Center??
Yes, this works. The action you want is "Show Remote Control".


Re: telnet control of DM-RMC scaler

 

Back in the early days of the DM-MD8x8, there were no private addresses for the DM endpoints.? Instead everything was on the same subnet as the DM chassis.? Later firmware allowed you to switch to a private subnet in DM Tools.? In more recent firmware releases, it looks like you can still turn off the private subnet for end points using the "PRIVATENETConfig" console command.? I've never tried it but it looks like you can still put on the end points on the same subnet as the chassis using this command. Use "PRIVATENETConfig ?" to get help on how to do this.

It is also possible to talk to DM endpoint via the LAN port if it is not connected to a DM chassis.? In that case the end point's LAN port will default to DHCP and you can drop DM-RCM-xxx on an Ethernet slot in your program instead of on the DM chassis..? If have done this in several cases where I use a DM-RMC-4KZ-100-C as a balun when combined with a DM-TX-xxx transmitter. However, if the end point connected to a DM chassis, it will cause a network loop if you attached the LAN jack of the end point to your network.

Now whether you can control the endpoint via telnet, I do not know as I have never tried that.


Re: telnet control of DM-RMC scaler

 

Of course I'm assuming this isn't a client, you could use a new processor in that case, I just assume you're going via tcp commands for some kind of lab/personal thing.


On Fri, May 27, 2022 at 2:06 AM J.B. Parker via <jbparker216=[email protected]> wrote:
For something like this I would probably just rack up an old mp2e from ebay. You can enable?external network mode on the switcher to give it an ip, I'm not sure if there's a documented telnet protocol though, the switchers are kind of unique in that way.

On Thu, May 26, 2022 at 7:25 PM ebalsley via <ebalsley=[email protected]> wrote:
I'm building an external control system that will send simple commands to a Crestron DM using TCP (telnet) commands.? This works fine with the DM-MD8x8.? But I'm not sure how to switch inputs on the DM-RMC-4KZ-SCALER-C.? This device doesn't have a regular IP address because it receives its input from the DM over HDbaseT.? Is there some way to talk to this device through the network?


Re: telnet control of DM-RMC scaler

 

For something like this I would probably just rack up an old mp2e from ebay. You can enable?external network mode on the switcher to give it an ip, I'm not sure if there's a documented telnet protocol though, the switchers are kind of unique in that way.


On Thu, May 26, 2022 at 7:25 PM ebalsley via <ebalsley=[email protected]> wrote:
I'm building an external control system that will send simple commands to a Crestron DM using TCP (telnet) commands.? This works fine with the DM-MD8x8.? But I'm not sure how to switch inputs on the DM-RMC-4KZ-SCALER-C.? This device doesn't have a regular IP address because it receives its input from the DM over HDbaseT.? Is there some way to talk to this device through the network?