Mag322 (Infomir) STB?IR?code ?
Hi
Looking for some IR captures of remote of Infomir STB (more specifically MAG322) although it looks to be same remote for all models. I found out an IP protocol but it looks quite cumbersome to get simple commands control. Someone got experiences with these ? or IR capture of the remote ? Thanks ³Õ¾±²Ô³¦¨¨²Ô |
Re: S# Pro on RMC4 with a DM-XIO-DIR
#rmc4
Are you familiar with Answer ID?1000315?? Even with less than 65 endpoints defined, I have still seen similar issues with overloading the processor - I would recommend trying the commands in that section to see if it improves things. On Thu, May 26, 2022 at 11:45 AM Mark via <junkmailhangar=[email protected]> wrote: I have a program that defines a director, four NVX units, adds them to the unit and then registers the lot. I receive very odd messaging in the error log and am not sure where to begin looking. Another odd behavior is attempting to stop the program takes a very long time. Has anyone seen this before: |
Re: SW-VMK-WIN
¿ªÔÆÌåÓýYeah, i think it?s similar to EventGhost which i?ve used in the past. I was just thinking using the Crestron tool would be easier to interface as there are already drivers in SIMPL, but if the tool isn?t working, that?s not helping. ? @Chris ? Cheers, Thorsten ? Von: [email protected] <[email protected]> Im Auftrag von Geoffrey Reynolds ? MCE Controller works really well: ? ? Pair it with a TCP Client symbol in your SIMPL program and you're good to go.? I've been using it for years without any issues. ? Geoff ? On Mon, May 30, 2022 at 4:09 PM Thorsten K?hler <thorsten.koehler@...> wrote:
|
Re: SW-VMK-WIN
If you¡¯re asking about MCE controller, I think so, but I have only used it to initiate actions on the PC from the Crestron side. Geoff On Mon, May 30, 2022 at 7:55 PM ckangis <chris@...> wrote: Just curious, |
Re: SW-VMK-WIN
MCE Controller works really well: Pair it with a TCP Client symbol in your SIMPL program and you're good to go.? I've been using it for years without any issues. Geoff On Mon, May 30, 2022 at 4:09 PM Thorsten K?hler <thorsten.koehler@...> wrote:
|
SW-VMK-WIN
¿ªÔÆÌåÓýHi, ? i need to control a Windows 10 PC from a Crestron touchpanel and wanted to give the VMK-WIN a try. It installs fine and the service is running, but it doesn?t seem to work correctly. For instance the Crestron symbol that should appear in the system tray after reboot is missing. Any ideas or is this tool just too old for Windows 10/11? ? Cheers, Thorsten |
Re: 70 series VTP default page when processor offline
I'd do a modal subpage that is fed by the reserved join for panel offline.? On Mon, May 30, 2022, 3:01 PM RK-X <rkx1984@...> wrote: Bit of an embarrassing one here, You can display a page prior to processor online when panel boots (Page 1) *System startup, Please wait* I'm sure there was a way to display that page when the processor goes offline after successful System boot *System Failure - Call xxxxxx* |
70 series VTP default page when processor offline
Bit of an embarrassing one here, You can display a page prior to processor online when panel boots (Page 1) *System startup, Please wait* I'm sure there was a way to display that page when the processor goes offline after successful System boot *System Failure - Call xxxxxx*
I normally wouldn't bother because fusion handles notifications for Support. This is a non fusion setup with an old fashioned email alert. Did a test on a brand new panel and page 1 never shows when CP4's network is pulled. Please someone jog my memory or tell me I dreamt it... |
Biamp Tesira X400 - VOIP dialer not controlled via Crestron
Good day all,?
Trying to control the VOIP dialer within a Tesira Forte X400 unit.? The dialer from the DSP/Tesira software works.? However, i cannot get the VOIP dialer to initialize with the 3.0 or 3.2 module versions.? Leve/mute/state controls work well. Just the VOiP dialer does not work at all. If I set the Enable for VOIP low, then Command processor module init completes.? I did confirm both VOIP instance names from the DSP file. Copied and pasted to be sure program tags match the DSP file.?? Any ideas of how to work around this?? Tesira Forte x 400 FW: 4.2.4.5 Thanks,? Tray #Biamp # DSP |
Re: Launching a 3rd party app from the crestron go app
#crestronapp
Hi Tony, i've only just started using shortcuts and they could be very handle. Shortcuts works like a command list or schedule list. A Shortcut can also adds a icon on the iphone home page. Basically you can use the shortcut to open one or more apps. Its a good workaround if you can't find or a app doesn't have a URL scheme.??
|
Re: telnet control of DM-RMC scaler
I'm not sure about a DM-MD8x8 but I know in a DMPS3 you can pass telnet through the DMPS3 to the endpoint on certain ports.? Try doing a DUMPDMIPCONFIG?on the 8x8 and see if it gives you a table that looks something like this: TableStart: DM IP Config Slot# ? ? ? ? |Device_Name ? ? ? ? ? ? |FW_Version ? ? ?|Ext_IP_Address |TCP_Port|Int_IP_Address |LINK |MAG ----------------------------------------------------------------------------------------------------------- 8 ? ? ? ? ? ? |C2I-DMPS3-4K-AUDIO ? ? ?|1.3711.00005 ? ?|10.111.7.113 ? |50003 ? |169.254.0.3 ? ?|UP ? |N ? 9 ? ? ? ? ? ? |C2I-DMPS3-4K-350-VIDEO ?|1.3458.0033 ? ? |10.111.7.113 ? |50004 ? |169.254.0.4 ? ?|UP ? |N ? 9.1 ? ? ? ? ? |DMPS3-4K-300-HDMI-RX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ? 9.2 ? ? ? ? ? |DMPS3-4K-300-HDMI-RX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ? 9.3 ? ? ? ? ? |DMPS3-4K-300-HDMI-RX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ? 9.4 ? ? ? ? ? |DMPS3-4K-300-HDMI-RX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ? 9.5 ? ? ? ? ? |DMPS3-4K-300-HDMI-RX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ? 9.6 ? ? ? ? ? |DMPS3-4K-300-HDMI-RX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ? 9.7 ? ? ? ? ? |DMPS3-4K-300-DM-RX ? ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ? 9.8 ? ? ? ? ? |DMPS3-4K-300-DM-RX ? ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ? 9.9 ? ? ? ? ? |DMPS3-4K-STR ? ? ? ? ? ?|1.3459.00091 ? ?|10.111.7.113 ? |50009 ? |169.254.0.9 ? ?|UP ? |N ? 9.11 ? ? ? ? ?|DMPS3-4K-300-HDMI-TX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ? 9.12 ? ? ? ? ?|DMPS3-4K-300-HDMI-TX ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ? 9.13 ? ? ? ? ?|DMPS3-4K-300-DM-TX ? ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ? 9.13.1 ? ? ? ?|DM-RMC-4KZ-SCALER-C ? ? |1.3991.00063 ? ?|10.111.7.113 ? |50007 ? |169.254.0.7 ? ?|UP ? |N ? 9.14 ? ? ? ? ?|DMPS3-4K-300-DM-TX ? ? ?|1.3458.00047 ? ?| ? ? ? ? ? ? ? |00000 ? | ? ? ? ? ? ? ? |DOWN |N ? 9.14.1 ? ? ? ?|DM-RMC-4KZ-SCALER-C ? ? |1.3991.00063 ? ?|10.111.7.113 ? |50008 ? |169.254.0.8 ? ?|UP ? |N?? What this means is if you telnet into the DMPS3-4k (10.111.7.113) on port 50007 or 50008, you will actually be telnetting into the scalers connected by DM. On Thu, May 26, 2022 at 7:25 PM ebalsley via <ebalsley=[email protected]> wrote: I'm building an external control system that will send simple commands to a Crestron DM using TCP (telnet) commands.? This works fine with the DM-MD8x8.? But I'm not sure how to switch inputs on the DM-RMC-4KZ-SCALER-C.? This device doesn't have a regular IP address because it receives its input from the DM over HDbaseT.? Is there some way to talk to this device through the network? |
Re: Launching a 3rd party app from the crestron go app
#crestronapp
Alex,Yes, this works. The action you want is "Show Remote Control". |
Re: telnet control of DM-RMC scaler
Back in the early days of the DM-MD8x8, there were no private addresses for the DM endpoints.? Instead everything was on the same subnet as the DM chassis.? Later firmware allowed you to switch to a private subnet in DM Tools.? In more recent firmware releases, it looks like you can still turn off the private subnet for end points using the "PRIVATENETConfig" console command.? I've never tried it but it looks like you can still put on the end points on the same subnet as the chassis using this command. Use "PRIVATENETConfig ?" to get help on how to do this.
It is also possible to talk to DM endpoint via the LAN port if it is not connected to a DM chassis.? In that case the end point's LAN port will default to DHCP and you can drop DM-RCM-xxx on an Ethernet slot in your program instead of on the DM chassis..? If have done this in several cases where I use a DM-RMC-4KZ-100-C as a balun when combined with a DM-TX-xxx transmitter. However, if the end point connected to a DM chassis, it will cause a network loop if you attached the LAN jack of the end point to your network. Now whether you can control the endpoint via telnet, I do not know as I have never tried that. |
Re: telnet control of DM-RMC scaler
Of course I'm assuming this isn't a client, you could use a new processor in that case, I just assume you're going via tcp commands for some kind of lab/personal thing. On Fri, May 27, 2022 at 2:06 AM J.B. Parker via <jbparker216=[email protected]> wrote:
|
Re: telnet control of DM-RMC scaler
For something like this I would probably just rack up an old mp2e from ebay. You can enable?external network mode on the switcher to give it an ip, I'm not sure if there's a documented telnet protocol though, the switchers are kind of unique in that way. On Thu, May 26, 2022 at 7:25 PM ebalsley via <ebalsley=[email protected]> wrote: I'm building an external control system that will send simple commands to a Crestron DM using TCP (telnet) commands.? This works fine with the DM-MD8x8.? But I'm not sure how to switch inputs on the DM-RMC-4KZ-SCALER-C.? This device doesn't have a regular IP address because it receives its input from the DM over HDbaseT.? Is there some way to talk to this device through the network? |