¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Re: Sony VPL-FHZ75 Serial control

 
Edited

Sony projectors use 38400 Baud on the 9pin Sub-D, but 19200? 9600on the RS232 over HDBT. (Corrected Baud Rate, thanks to Bambam_101)
+1 for EVEN as mentioned by Brendon, both on Sub-D and RS232 over HDBT.

Best regards
Crestronfreak55


Re: Toolbox Debugger does show the state changes but not the signal names anymore

 

Thanks Tony,

the column width was the issue.
Resolved!

Best regards
Crestronfreak55


Re: Toolbox Debugger does show the state changes but not the signal names anymore

 

I also found this when I opened up toolbox on an old virtual machine. If I recall correctly it was something to do with the low resolution setting I had in the virtual machine, I just had to resize the columns (or make the toolbox window bigger) as all the signal info had been simply pushed off to the right out of view.
TH

Il giorno sab 26 giu 2021 alle 16:39 ckangis <chris@...> ha scritto:
Give us your Software versions list....

--
Regards
Tony Howard
?
?T???|???B???|???T?
?
|??tony@...??|??+39 333 5971791?


Re: DSC Neo module?

 


Where you able to get any integration with DSC Neo?? Looking for way to control it.

Luis


Re: Yale Lock Aquire

 

Thanks,

That did the trick.? Everything acquired and working now.


Re: Sony VPL-FHZ75 Serial control

 

Sony projectors use even parity, it's tripped me up once or twice.

-Brendon

On Sat, Jun 26, 2021 at 6:44 PM Benjamin Brotcke <BBROTCKE@...> wrote:
Check your baud rate.

On Sat, Jun 26, 2021, 2:19 PM <williamtejral@...> wrote:
I have been using IP and CEC to control displays for quite some time. I am now working on a system using RS-232. There are 2 Sony Bravia panels that are working correctly, but I am having issues with the Projector. Using both Crestron Certified Drivers and and older module, all I get as return is?\x00x\x00\x00\xf8\xf8. since it is formatted and comes after something is sent, it seems I have the Tx/Rx and the baud rate correct. The on-screen menu only references HDBaseT rs-232. Does anyone know of necessary setup on the? VPL-FHZ75? Thanks in advance.

--
Brendon Packwood


Re: Sony VPL-FHZ75 Serial control

 

Check your baud rate.


On Sat, Jun 26, 2021, 2:19 PM <williamtejral@...> wrote:
I have been using IP and CEC to control displays for quite some time. I am now working on a system using RS-232. There are 2 Sony Bravia panels that are working correctly, but I am having issues with the Projector. Using both Crestron Certified Drivers and and older module, all I get as return is?\x00x\x00\x00\xf8\xf8. since it is formatted and comes after something is sent, it seems I have the Tx/Rx and the baud rate correct. The on-screen menu only references HDBaseT rs-232. Does anyone know of necessary setup on the? VPL-FHZ75? Thanks in advance.


Sony VPL-FHZ75 Serial control

 

I have been using IP and CEC to control displays for quite some time. I am now working on a system using RS-232. There are 2 Sony Bravia panels that are working correctly, but I am having issues with the Projector. Using both Crestron Certified Drivers and and older module, all I get as return is?\x00x\x00\x00\xf8\xf8. since it is formatted and comes after something is sent, it seems I have the Tx/Rx and the baud rate correct. The on-screen menu only references HDBaseT rs-232. Does anyone know of necessary setup on the? VPL-FHZ75? Thanks in advance.


Re: ATEM Television Studio HD

 

Hi All,

sorry for the late update.
Unfortunately I had the same issues as described by S¨¦bastien LENOIR: no reliable communication.
I ended up adding a Skaarhoj TCP ATEM Link device. This thing is rock solid, provides unsolicited feedback of changes, runs for approx a year now.

I just received an ATEM Mini PRO, updated it to version 8.6.1 and tested the module again.
This is a really small system with an old MPC M-25, containing a C2N-CAMIDJ, a VISCA over IP driver and the ATEM Mini PRO.
So far this system runs with no issues using the modules from the files section.
I think the issues are related to timing, since the ATEM seems to be very picky on timing.

Best regards
Crestronfreak55


Re: Toolbox Debugger does show the state changes but not the signal names anymore

 

Give us your Software versions list....


Toolbox Debugger does show the state changes but not the signal names anymore

 

Hi Folks,

I think I had this before, but cannot remember the root cause/solution.
In Toolbox Debugger, the trace shows the state changes, but not the signal names anymore.
I did not change anything (at least nothing I am aware of).

Any ideas?

Thanks
Crestronfreak55


Re: Rebooting a UC Engine via Code

 

Thanks.

I thought the console symbol could only be used for the processor and not a connection to the UC Engine?

I can see port "41797: Tunnel is ssl: unknown service" is available on the UC Engine, i will try that. Previously i only tried connecting to port 443


Re: Simpl+ Parsing Help

 

Contrary to the suggestions above, I would recommend using the Gather() or GatherAsync() functions for this with CRLF as the delimiter.

--
?
Crestron Service Provider - TBD Enterprises Inc.


Re: Rebooting a UC Engine via Code

 

Yes.
I use it quite frequently, it's part of the Foundation I put into all my programs.
I use it on the settings page for a "PROGLOAD -P:ALL, Named "Install Update".? This is so I can load code to the Processor, and wait to have the Field Tech Install the program when they are there, or when the customer is ready to.
I also use it the "PROGRES -P:01" "As a Program Restart" as apposed to a reboot, on the same settings screen.

I used a TCP/IP_Client (Port 41795d, Tied to the Address of the Processor)
? ? ?Simply take the TX$/RX$ to an SIO.
? ? ?The commands are the same as in Text Console + \n (i.e. PROGLOAD -P:ALL\n) ; I just put the \n in the [delimiter].

My Sr. Programmer chooses to use the Symbol "User Program Command" Tied to an SIO (same Parameter formatting), with the TX$ Tied to a "Console" symbol.
? ? ?The "Console" symbol being what your looking for.



Re: Somfy URTSI II

 

I Believe that shades can have multiple addresses, so you can send a "1","2","3" for individual shade control; "5" for Room Control; and "20" house control.
It sounds like your shade has both addresses 6, and 8. in it, so it's responding to both codes sent.


Re: NVX not showing up as online in IPTable

 

Hi,

I encountered the same problem this week with a customer with 2 units and the only solution was a restore as well. ?I have had this problem following several power and network outages.


Re: Yale Lock Aquire

 

I agree.
The Batteries, are very important.?
DO NOT "Hot Swap" the RF Module, they are fragile.


Rebooting a UC Engine via Code

 

Has anyone been able to do this?

Apparently, you need to write a TLS console connection to the UC which then allows you to send "reboot" via the console (like via Toolbox)
This connection needs "admin" "sfb" prefilled.


Simpl controlled devices into XIO cloud #xio #simpl

 

Hello tribe,

Is there any easy way of getting a simpl controlled third party device into XIO?
There is no certified driver for this very make/model but a rather trivial TCP-protocol on port xxx. (think of RS-232 over IP)

Obivously the real deal would be to write a real XIO-enabled driver with the driver SDK, but doing this for just a few monitors in a single project is beyond the budget...

During masters 2021 the topic has been briefly mentioned as "coming soon" but anybody know any time frame?

?

Any ideas? Thanks for your help

HST


Re: Simpl+ Parsing Help

 

You need to search (in a loop) for a string starting with a Space and ending in .mov Then locate the \x0D\x0A delimiter in that new string and remove just the chars after the delimiter which is the movie filename.

You then must handle the very first entry as it different with just the filename at the start.