¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Re: Big Ass Fans

 

I wrote one that does most of the basic features. I wrote it before realizing that one may connect over TCP, so I implemented retransmit logic for UDP. It has been absolutely flawless for me; for two of our fans, I use the light in the fan as one of the room lights, turning on and off with the other lights. I also automate the fans to run during HVAC calls, so it gets plenty of activity. I will upload it to the file section. It wouldn't be hard to change it to TCP if you so desired. I haven't done so because UDP seems good. I do have a fairly robust WiFi network (UniFi) and sometimes the fans take a few seconds to respond (implying a few retransmit cycles) but so far they always do.
-jason

On Fri, Jan 20, 2017 at 9:25 AM, drh_784@... [Crestron] <Crestron@...> wrote:
?

Matt,


Did Big Ass Fans ever send you their Crestron driver? If so, would you mind sharing it?

I have a customer with two fans and an Element wall controller. Told them I would look into controlling it from Crestron.

Thanks,
David



Re: Big Ass Fans

 

Matt,

Did Big Ass Fans ever send you their Crestron driver? If so, would you mind sharing it?

I have a customer with two fans and an Element wall controller. Told them I would look into controlling it from Crestron.

Thanks,
David


Biamp Netgear GS724Tv4 questions RE streaming on crestron subnet

 

Ok, so I want to multicast stream a preview monitor to 3 TSW 1060. The System will already have a?Netgear GS724Tv4?for Biamp AVB--can I make a VLAN for the Crestron subnet with IGMP snooping apart from the Biamp AVB network, or will I need to add a seperate switch for this? Any experience with this? I will have a DM Matrix and a DM-txrx-100 to create the stream.

?


Re: Discreet Input IR Commands for Samsung Sound bars (HW K950)

 

The HW-J250 has discrete input commands that you could try. You can get the codes from the Global Cache' Control Tower database.


Re: Crestron DM System - Detecting a DM transmitter by IPID

 

x = the input card number. ?You would pre-populate all the DM input cards in simpl windows with a transmitter and then also add an offline manager for each transmitter. ?When a transmitter comes online, its offline manager will determine the value of x and thereby "rcon slot x.1 est\r" can query the mac address of the transmitter connected to that particular input card. ?Obviously this command needs to be sent to a TCP client on port 23 to the DM Frame IP Address.


Arcam AVR850 IP

 

I'm using the Crestron?IP module from the Arcam website but the results have not been stellar.? Unit locks up and must be hard rebooted (after a Crestron processor upload); it cycles itself on and off.? Generally, it is flaky.


The module seems straight-forward.? If anyone is successfully using it please let me know and I'll redouble my efforts to locate my? error.

On the other hand, if you've had issues please let me know.

Thanks



Discreet Input IR Commands for Samsung Sound bars (HW K950)

 

Wondering if any has come across Discreet Input IR commands for samsung sound bars (HW K950) i got a project where we have the TV audio on the digital input, and separate music input on the analog in. I would like to switch inputs on the sound bar but i doubt there will be any.


Thanks.


TSWPanels ANd Holovision VIO cr

 

Does anyone have a sample program to work with this unit ? trying to figure how to communicate with it to trip relays, adjust tones and Vol Etc. Thanks


Re: Crestron DM System - Detecting a DM transmitter by IPID

 

yeah i only have to do this for 4 transmitters, so wont need to read and write. question though in this command "rcon slot x.1 est\r" what is the x.1? if i wanted to query input 4/5/6/7 on a DM 16x16 frame how would that string look for each?


Re: Samsung TVs IR control discrete power on doesn't work after being off a long time

 


With all the Energy Smart stuff we've found many devices need a little push to wake up. On most of our Samsung models we send the power on command twice,(power off too) works every time


Re: Bose Soundtouch 300

 

Did you ever figure this out??


Updated SmartThings Interface Code

 

Something changed on either the SmartThings or Crestron side that introduced a bug in the code for an occupancy sensor connected a SmartThings hub. ?I've loaded an update onto github. ?In addition, because people where having trouble getting the code configured properly I've added documentation in the github readme file for the project on how to properly get all this configured.?

Thanks to Casey for his help on this.

The code can be found here


Thanks

Jay


Re: Lighting based on multiple occ sensors

 

IMO, it wouldn't work very reliably because the Occ sensors have timeouts and can be tripped from multiple distances.? You'd be better off putting a beam sensor at each end of the stairs and then monitoring sensors to determine direction.

Top or bottom of stairs gets tripped and sets a latch.? When you get to the other end (or turn around and cross the beam again), it clears the latch.? If neither end is latched, when you cross a beam, then it will know which side you are coming from and trigger the correct loads.

Example:

Trip the beam at top of stairs
IF the top beam is already latched (you've turned around) then clear the latch
IF the bottom beam was crossed then clear the latch for the bottom beam
IF the bottom beam hasn't been crossed then turn on the lights at the bottom of the stairs and set a latch.

Trip beam at bottom of stairs
IF the bottom beam is already latched (you've turned around) then clear the latch
IF the top beam was crossed then clear the latch for the top beam
IF the top beam hasn't been crossed then turn on the lights at the top of the stairs and set a latch.


Re: Samsung TVs IR control discrete power on doesn't work after being off a long time

 

¿ªÔÆÌåÓý

OP

?

Try using the UN55ES8000 IR codes from the Crestron Database.? Been using it for years for discrete¡¯s, up to this year¡¯s KS9000

?

Trey

?

From: Crestron@... [mailto:Crestron@...]
Sent: Tuesday, January 17, 2017 4:39 PM
To: Crestron@...
Subject: [Crestron] Samsung TVs IR control discrete power on doesn't work after being off a long time

?

?

This is strange but something that we've noticed with two Samsung TVs on a particular job: If "warm" then the discrete power code for "on" works fine. But if "cold" ie first time turned on in the morning, then the power on code never works first time. The factory remote with its toggling code always turns them on just fine. This is the same Samsung discrete IR codeset I've used for years which I think got from this group originally (Samsung UN46B8000XF.ir).?

?

Anyone seen this before? Does sending multiple power commands eventually wake it up? Not on site to test, getting this third had from tech on site.

?

Thx in advance

?

OP

?


Re: Lighting based on multiple occ sensors

 

Assuming 2 motion detectors (one at the top of the stairs and one at the bottom). ?One solution is to run the motion detectors into logic wave pulse symbols so the output of the motion sensor is reduced to a single logic wave and can then be run into a truth table without worrying about circular logic. ?If the top of stair or bottom of stair motion detector is tripped and the other motion detector hasn't been tripped (latch is clear) then start the appropriate scene and set the latch. ?If one of the motion detectors is tripped and the latch is set then don't do anything because you've already started your lighting scene.

Every time a motion detector is tripped trigger a retriggerable one shot. ?This is going to be the timeout period for the lighting scene. ?After the ROS has expired the person has left the stairs and you can turn off the lighting scene and clear the latch. ?

I personally like using truth tables.?

This is going to require some real world testing. ?You could have issues with multiple people going different directions, etc. It will depend on how your scenes act.

Hope this helps

Jay

------ Original Message ------
From: "ComeAlive@... [Crestron]" <Crestron@...>
Sent: 1/19/2017 2:05:52 PM
Subject: [Crestron] Lighting based on multiple occ sensors

?

Have a client that has multiple occupancy sensor in his staircase and would like to trigger different loads in different ways depending on which direction he is going. Up versus down of course. ?Anybody done something similar and would like to share? ?Or suggest ideas on just how to accomplish this.


Re: Multi zone hvac control.

 

CoolMaster Net

On Jan 19, 2017 3:30 PM, "dave.dunaway@... [Crestron]" <Crestron@...> wrote:
?

Are there any new hvac zone controllers that communicate in similar fashion to the old carrier comfort zone systems?



Lighting based on multiple occ sensors

 

Have a client that has multiple occupancy sensor in his staircase and would like to trigger different loads in different ways depending on which direction he is going. Up versus down of course. ?Anybody done something similar and would like to share? ?Or suggest ideas on just how to accomplish this.


Re: Adding a stop command after PZT action controlling a camera

Bob Smith
 

Thanks for the reply guys worked perfectly!


On Thursday, January 19, 2017 3:11 PM, "oliver.hall@... [Crestron]" wrote:


?
Fair point Chip.



Re: Adding a stop command after PZT action controlling a camera

 

Fair point Chip.


Multi zone hvac control.

 

Are there any new hvac zone controllers that communicate in similar fashion to the old carrier comfort zone systems?