SONOS and NAX audio zone grouping in Crestron Home #crestronhome #sonos

 

Hello,

Is there a way to group audio zones using both SONOS amps and Crestron NAX zones?

Thanks.


Re: DM-NUX multi-device pairing through SIMPL

 

Here's True Blue Support's Apr.2022 USB Routing Example/Demo (for DM-NUX, USB-NX2, NVX).
/g/crestron/files/DM-NUX%20-%20USB-NX2%20-%20DM-NVX%20Demo.zip?

?


Re: CCD Samsung QLED can't connect

 

Does this happen to be VC4?


Re: What is this??

 

Have seen this a bunch. setting HYDROGENENABLE OFF and rebooting gets rid of it. Its funny as when I brought it up to support, that is exactly what they told me to do. No explanation of what it is or why I would/wouldnt want it.?

Sadly it seems lately I see so many errors that are unexplainable by tech support. You would think someone knows what they mean...


Re: Streamer recommendations

 

Bluesound Node 2i
They have driver for Crestron including SG Media Player


Re: TSW-760 - The server that the application is connecting to is unverified

 

Checking the Favourites URL's on the Sonos, I see the following:?
Which is one of my Amazon Playlists.
I've had this playlist on Sonos for years. Why has it started acting up?


TSW-760 - The server that the application is connecting to is unverified

 

The above Cert error keeps popping up on my home 760. I think it started last week but is driving everyone at home nuts.

The full message is:
The server that the application is connecting to is unverified
Server: m.media-amazon.com

This is related to Sonos as it only pops up when the Sonos subpage is active (not media player - good ol' fashioned transports & favourites SRL)
Both CP3 & TSW times match so not a time issue. This only appears to happen on one panel and also does not occur on Crestron Go.

And yes my Sonos is linked to my Amazon account for Music.

Any suggestions?
Thanks


What is this??

 

Hi All,
Has anyone seen this before?? I'm called into a service for a site I had nothing to do with...
Is the some sort of standard log entry or is it something from a custom code feature??

?12. Warning: CPHProcessor.exe # 2023-06-05 14:45:32? # Buffer doesn't have Device Member in the Telemetry Update and payload is {"Actions":null}

TIA!


Re: CCD Samsung QLED can't connect

 

1515 is the port in the dat file
i see the error in debugger & processors error log


Streamer recommendations

 

?Greetings group. Currently we had an Autonomic wich has stopped working. I am looking now to add a Streamer mainly just for phone use. SO guests to the residence guest house can easily connect their own devices. I do want it to be compatible with Smart Graphics also. I was thinking of the Autonomic MMS-1e but seeing if there is a more basic product. Thanks


Re: CCD Samsung QLED can't connect

 

From my experience, Samsung IP control, ESPECIALLY if using Wi-Fi, is unreliable and should be avoided.

I can't tell if those messages are coming from the processor's Error Log, or the CCD module's Log output. The latter usually contains important clues when it's not working. I always give it a real signal name and connect it to an MSP, so I can watch it in Debugger.

Also, some Samsung TVs use port 1515, and others use 1516. Although the .dat file will specify the port to use, if your exact TV model isn't listed in its list of supported models, it could be different.

--- On Monday, June 5, 2023 at 9:58 AM, mark kaye wrote:

1st time using CCD on a display
keep getting
00:00:46.516 044-07:55:22.411 ( 1) [Info ] CORD | QLED Series :
Sending command 'GetAccessToken' to transport
00:00:47.734 044-07:55:23.624 ( 1) [Debug ] TSPT | HttpTransport :
Connection failed, error code: UNKNOWN_ERROR, connection failure elapsed
milliseconds: 31,993.

i get DriveLoaded, but connect fails
display is wifi
macaddr is correct & sending into attribute 4 before connect

display has both IP controls enabled


CCD Samsung QLED can't connect

 

1st time using CCD on a display
keep getting
00:00:46.516? ? ? ? 044-07:55:22.411 ( 1) [Info? ?] CORD | QLED? Series? ? ? : Sending command 'GetAccessToken' to transport
00:00:47.734? ? ? ? 044-07:55:23.624 ( 1) [Debug? ] TSPT | HttpTransport? ? ?: Connection failed, error code: UNKNOWN_ERROR, connection failure elapsed milliseconds: 31,993.

i get DriveLoaded, but connect fails
display is wifi
macaddr is correct & sending into attribute 4 before connect

display has both IP controls enabled


Sansi V3S4K

 

Has anyone controlled a Sansi V3S4K video processor with Crestron. ?I am not finding a lot of documentation for this product. ?


Re: Upgrading from CEN-RFGW-EX to CEN-GWEXER

 

Yea they used to have a Gateway Backup/Restore in Toolbox. From what I remember you could only do it once for whatever reason. Doesnt look like that option is even available anymore.?


Re: Upgrading from CEN-RFGW-EX to CEN-GWEXER

 

Thanks for the reply ckangis. I guess there is no quick way out.?
EQ



On Thu, Jun 1, 2023 at 10:36 AM ckangis <chris@...> wrote:
I believe that with the GWEXER, there is some sort of config file that theoretically allows for transfer devices from one GWEXER to another.
BUT, I'm quite sure that you will not be able to move the acquirements of the devices from the RFGW-EXs to the GWEXERs...

You can determine the RFIDs assigned to each gateway via Toolbox - text console (use REPORT command) or Network Device Tree. Then you'll have to put the GW into Acquire Mode and re-acquire each device. If you have a device map, it shouldn't take a super long time once you get going...Just obviously do only one gateway at a time...

Migrating the devices in SMW is definitely the 'Simpl' part of your equation...

Others might have a secret that I don't know about...


Re: HZ THSTAT USB

 

I can confirm that the Toolbox/Thermostat setup tool does work with the HZ stats...


Re: Crestron Home Losing Control of Roku using IP #cp4r

 

Have asked Crestron to update the driver to allow the Roku to be accessed by MAC address or Serial Number for years.

The Roku driver we wrote allows IP Address/MAC Address/Roku Serial Number to refer to the device.? No requirement that the Roku live at a fixed IP address.

Roku has supported device discovery for years.? Crestron has chosen to not utilize that capability.


Re: HZ THSTAT USB

 

Hi Zac and Nico,

Thank you both for your help.? ?It turns out my direct USB-C to Micro USB cable did not work.? ?I switch to a USB-C to USB hub, and then used a USB - Micro USB and then things started working,? ?Will have at a later date do some more testing with other USB-C to Micro USB cables.

Bryan


Re: HZ THSTAT USB

 

¿ªÔÆÌåÓý

Didn¡¯t know that the horizon thermostar can be setup
Through toolbox, good to know.
Cheers
Nixo

NFH

On 3 Jun 2023, at 12:37, zac.sparrow@... wrote:

?Both of you are correct and wrong. Your USB adapter/cable combo lickely doesn't pass data and just power it on.?

If you don't have another cable, all settings are available thru OSD like Nico said?


Re: HZ THSTAT USB

 

Both of you are correct and wrong. Your USB adapter/cable combo lickely doesn't pass data and just power it on.?

If you don't have another cable, all settings are available thru OSD like Nico said?