¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Accessing the internal cp3 web page

pearce.bruce
 

Hi All?

I have been trying to access the internal setup page within the cp3 ( this was never an issue on previouse firmware versions ) but I now get a login screen .
This is the first time I have come across this and dont know what the defaulty is . I dont have authentication enabled and I cant think what else it could be .

Thanks?
Bruce


Re: SIMPL Error?

 

Yeah, I can send/transfer the program just fine after acknowledging the error.?

I DO have a 1 on the debug line of the Biamp modules. I think I just mirrored what the sample program showed and moved on due to autopilot.?

Debugger is NOT running in the background.?


Re: SIMPL Error?

 

¿ªÔÆÌåÓý

The engine running behind Toolbox and SIMPL to manage comm is really fragile ¨C if it gets anything at all unexpected back it pops up that message ¨Cquite frequently I¡¯ll get the top 1/3 of an IP table as the unexpected response for some reason or if I have debugger open at the same time as I¡¯m doing a file transfer.

?

In your case it appears that the Biamp module barfed the error (I¡¯m guessing you have debug on the Biamp module enabled/held high) at exactly the moment Toolbox was expecting something else. 99.999% of the time for me hitting ¡°Send¡± again works.

?

Lincoln

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] [mailto:[email protected]] On Behalf Of Rob
Sent: Wednesday, November 04, 2020 10:22 AM
To: [email protected]
Subject: [crestron] SIMPL Error?

?

The device reported an error:?

?

A connection attempt failed because the connected party did not properly respond after a period of time, or established connection failed because connected host has failed to respond ]?¨²¨¤BiampTesira4[ ConnectStatusChange: False ]?¨²¨¤BiampTesira2[ Error: A connection attempt failed because the connected party did not properly respond after a period of time, or established connection failed because connected host has failed to respond ]?¨²¨¤BiampTesira2[ ConnectStatusChange: False ]?.


Maybe this is totally irrelevant currently. This is the first time I've seen an error like this after hitting the transfer program button.

I'm just dumping programs for a project onto the processor, but nothing else is connected to the network, so if it's just an error stating that my Biamp processors aren't online, OK, I'll disregard. But I've never seen this error before. That is a direct copy/paste, including the funky characters.?

SIMPL Windows:? 4.14.21

SIMPL+? 4.05.01

Other Crestron SW:

? ? ? ? Device Database: 200.20.002.00

? ? ? ? Crestron Database (cnctrldb22000.mdb) :? 202.00.001.00

? ? ? ? Crestron Toolbox: 3.07.228.02

? ? ? ? SIMPL+ Cross Compiler: 1.3


Contract Editor Documentation

 

Does anyone know if there is any documentation or a training video that explains how the CH5 Contract Editor works? I found the documentation on the CH5 SDK web site at the link below and I understand how to create and build a contract but how do I use the contract in CH5 and Simpl# Pro? The SDK just says "Content Coming Soon"

https://sdkcon78221.crestron.com/sdk/Crestron_HTML5UI/Content/Topics/CE-Overview.htm


Ashly Pema crestron module

 

Anyone out there be willing to share a Ashly Pema crestron module?? I have an older module from blackteesystems that is only for series 2 and the module is locked so I can't access to try and recompile for series 3.? Thanks for any help.??


SIMPL Error?

 

The device reported an error:?
?
A connection attempt failed because the connected party did not properly respond after a period of time, or established connection failed because connected host has failed to respond ]?¨²¨¤BiampTesira4[ ConnectStatusChange: False ]?¨²¨¤BiampTesira2[ Error: A connection attempt failed because the connected party did not properly respond after a period of time, or established connection failed because connected host has failed to respond ]?¨²¨¤BiampTesira2[ ConnectStatusChange: False ]?.

Maybe this is totally irrelevant currently. This is the first time I've seen an error like this after hitting the transfer program button.

I'm just dumping programs for a project onto the processor, but nothing else is connected to the network, so if it's just an error stating that my Biamp processors aren't online, OK, I'll disregard. But I've never seen this error before. That is a direct copy/paste, including the funky characters.?

SIMPL Windows:? 4.14.21
SIMPL+? 4.05.01
Other Crestron SW:
? ? ? ? Device Database: 200.20.002.00
? ? ? ? Crestron Database (cnctrldb22000.mdb) :? 202.00.001.00
? ? ? ? Crestron Toolbox: 3.07.228.02
? ? ? ? SIMPL+ Cross Compiler: 1.3


Re: Help - S+ Module issue

 

Did try to recompile the s+ module.? But I didn't toggle the 3 series button.? I'll give it a shot.


Re: Help - S+ Module issue

 

Can't do much about the firmware.? It's an MC3 run 1.501 and 502 is latest.? I'll have to see what firmware of my other project that I saw this issue with the Integra volume control S+.


Re: OT: DirecTV

 

I don't know how to message directly in this platform, but feel free to email me Steven @ sbts-inc.com I should be able to help you out.?


Re: Crestron RMC3 with Cisco Touch 10 and Codec Pro

 

Hi,

Sorry for the late reply, i was on annual leave.?

I'm not revisiting this today and I've noticed I'm connecting to the Codec now but I can't get the button I've created on the codec web browser UI Extensions to talk to the RMC3.

I'm not getting any feedback on it at all.

Do I need certain script to go with this button on the Cisco end? Ive named my button DisplayPower?

Here's 2 images of how I have it setup if anyone can help. I've basically copied the signal routing of the demo program that Chris suggested

?


Re: Security Cams Integration (General Opinions)

Ivan Wild
 

... the crestron cam app ?... I thought that could only be used for local cam traffic.


Re: Security Cams Integration (General Opinions)

 

Just use the camera app for that application man.? That is not worth the battle.
--
Ryan Baldwin
CEO | XS Design Studios
rbaldwin@...
760.712.2240


Re: Security Cams Integration (General Opinions)

 

Sorry I can't be of much more help. I think you will need to get your hand on the Blue Iris system and see what can be done and what can't. I know it is a popular product but have my doubts that it will be able to do that. Hopefully I am wrong.?


Re: Security Cams Integration (General Opinions)

Ivan Wild
 

... because the nvr's have webservers built in... i am assuming that casting an ip address to a display window will show live video to each object window (simplified).

Again, I am taking a shot in the dark at putting this together.? I have seen the finished product of similar systems showing live vid in multiple windows...so it has to be possible.? That is why I am putting this out there... I need ideas, direction, samples... good thing there is no rush :)


Re: Security Cams Integration (General Opinions)

 

How are you going to show 4 live streams at once on a TP or iPad?


Re: Help - S+ Module issue

 

Try toggling series 2/3 off then on and recompile (inside S+).
Or dedete the SPI works folder.?


Re: Help - S+ Module issue

 

Make sure the processor is running at least firmware version 1.601.0050.

--- Tuesday, November 3, 2020 at 6:35 PM, John Gabler wrote:

So recently I have had an issue where older Modules with S+ embedded inside of
them stop working after compiling. Happen again today. Have a project with a
DBX Zone Pro 1261 in it. Last time the system was compiled was July 27,
2019. I imported the archive did a save as and made changes. Compile and
Upload and the modules are broken. Reload exist lpz and everything is
fine. Recompile original program and they break again. Any Ideas?

Simpl 4.11.06.1
CDB 90.00.004.00
DDB 115.08.002.00


Help - S+ Module issue

 

So recently I have had an issue where older Modules with S+ embedded inside of them stop working after compiling.? Happen again today.? Have a project with a DBX Zone Pro 1261 in it.? Last time the system was compiled was July 27, 2019.? I imported the archive did a save as and made changes.? Compile and Upload and the modules are broken.? Reload exist lpz and everything is fine.? Recompile original program and they break again.? Any Ideas?

Simpl? 4.11.06.1
CDB? ? 90.00.004.00
DDB? ? 115.08.002.00


Security Cams Integration (General Opinions)

Ivan Wild
 

Hi All,
This is a general discussion.? I did a quick search but nothing relevant came up - so lets have a conversation.

The request is to have the ability to see 16 cameras... (4 cameras per site - 4 remote sites)...(1 remote site will be moving all the time, construction site)... (1 remote site is mobile)
Each site has its own NVR matched to the cameras.. in this case all cameras are nikivision (or however it is spelled).? I know each NVR has webcast or webserver so capturing the feed should be pretty simple.
To be honest... its been quite a while since i integrated cameras, and when I did, it was all hardwired cctv... so I am a little behind the times here for cam integration.

The OP wants to use "blue iris" as he has been using it for a long time.? I have never used it.

Q1. What is the opinion of blue iris and or is there better universal software out there.

The OP would like to see 4 cam per screen on each of his devices... (to include, TV, Lighting Touch Pad, Dedicated System IPad, Mobile IPad, IPhone, Android Phone)
Only the IPads and Iphone and computer would operate any camera controls.? All the others would just show view.

So, for showing views... i am solid on that.? Its basically just a source in a window.
As far as integrating some symbols into the system to integrate with "blue iris"... I am not really clear on the best course of action.

Q2.? NVR.? I think matched NVR's at each site is the best instead of trying to bring all the feeds back to the main system and having a rack mount NVR there.? BUT, I am worried about up time or how easy it will be to maintain connections to 4 NVR's with floating IP's.? The webservers should sort some of this out.

OK...
So start the debate.? You know what I have to do... Now what should I do.? I am sure a couple of you have had to incorporate multiple dirty systems.? Does anyone have a sample program to share that I can look at and study.
- oh, and I don't know if this matters but I am stuck with a Pro2 system components.


OT: DirecTV

 

I need a consult on a DirecTV wiring question.? Happy to pay for an informed assessment on how to get DTV interconnected between two buildings.

Contact me directly if you have some expertise.

Thanks.