Re: multiple touchpanels


 

If I understand what you're saying correctly even using new joins would not
solve your problem. You need to use different signal names through buffers
to drive the same end result so that other then the end control device the
logic is identical but with different signal names. For example
TP-A_VOL_UP, would drive a buffer enabled with a 1 and on the output put the
device volume, REC_VOL_UP. The feeback to the panel would be The
TP-A_VOL_UP. This will sperate out the logic so yo don't see different
zones driving logic on different panels. Also you can quickly make the new
logic for the other 2 panels by copying the folder and then using Search and
Replace which is the F9 key. Hope that kind of points you in the right
direction.

Mark

On Jan 12, 2008 7:14 AM, Nightcountry <patrickbedford@...> wrote:

Hoping someone can help - have multiple touchpanels ( 2x stx1700c and a
tps4-l )with a mc2e processor...same program in all three and I find
they interfere with each other - volume ramps up inexplicably etc...
short of doing an individual program for all three with different join
numbers is there any way to separate the panels from each other? ie
in one zone someone engages a volume interlock and that same interlock
is now engaged for all zones....