Re: Extron dmp128 #simpl


 

¿ªÔÆÌåÓý

I had a dmp64 recently. To get it to work i did the following:

?

The first string the dmp sends after connection ends with ¡°password:¡±

Then you have to send the password.

Then you get a reply that you have logged in as administrator or user.

Then you can start sending the verbose mode and strings (e.g. ¡°I¡±) to keep the connection open. In my case the connection dropped after one minute and I haven¡¯t changed this in the settings.

?

Kind regards / Met vriendelijke groet,

?

Math

?

Van: [email protected] <[email protected]> Namens Scott
Verzonden: zondag 23 oktober 2022 16:49
Aan: [email protected]
Onderwerp: Re: [crestron] Extron dmp128 #simpl

?

@Andy, I know the password for the device.? That's not the issue.? The issue is the password is preventing the VC-4 from communicating with the DMP (At least that's my theory).?

?

I'm fairly new to the game, and still don't know all the tricks.? Is there a way to set the processor to remember passwords of various devices?? Also, I'm using a VC-4, running SIMPL program.? It's my 1st time programming a VC-4.

?

?

?

On Sun, Oct 23, 2022, 5:09 AM Andy Smith <asmith@...> wrote:

Password needs to be set on all extron devices now, it is the serial number of the unit



On 22 Oct 2022, at 21:05, Scott via <smschreiner10=[email protected]> wrote:

?

23. And I've followed instructions posted in previous discussions.? I've got an oscillator pulsing verbose 3 every 30 seconds.? I don't know if that's necessary.? The posts were from 2018, so could be outdated info.??

?

On Sat, Oct 22, 2022, 12:57 PM Audvizer <Audvizer@...> wrote:

Hi Scott,

are you using port 22023? Or port 23??