Re: Homeworks QS individual load control - Ro2 module question


 

Just finished implementing this today. ?I found that the module didn't seem to process all feedback correctly especially when a keypad press came in with the current level. ?I had to add a serial gather to make it work properly, which was also tricky because the login process doesn't use delimiters. ?The gather might help with the overflow if it isn't processing it correctly like mine was. ?

I was fairly unimpressed with this module as well because the ramping feature is not a true ramp. ?It gives the impression of ramping on the interface, but waits until you release the button to actually send the ramp command. ?I imagine they are trying to avoid an overload of values/commands being sent to and from the Lutron. ?Can anyone verify this?