Re: Panasonic AW-HE130


 

Maybe the Panasonics support HTTP 1.1 (to keep a connection open) but for some reason the Crestron module is using HTTP 1.0?

Using WireShark to look at the connection details when using IE would probably be a good start.

On Fri, Sep 11, 2015 at 5:39 PM, bassman233@... [Crestron] <Crestron@...> wrote:
?

Has anyone had success controlling an AW-HE130 over ethernet?? This project was supposed to get an HE-120 but they were out of stock (likely discontinued) so we got the 130.? Everything appears to be the same as the HE-120 except it is POE and supports streaming.

The module for the HE-120 (and HE-60/50) controls it, but the manual controls (pan/tilt/zoom buttons) run away if pressed for less than about 2.5 seconds.? The Panasonics use HTTP for control, and I can see in debugger that the connection drops after a response, and is slow to reopen, which seems to be how it is missing the 'stop' command.? Preset store & recall works fine, which is the bulk of the use on this job, but I need to give them a way to set presets.?

The web gui for the camera works flawlessly, but only works with IE, so I'm guessing there's something going on HTTP wise there that isn't happening from the module.? I've tried digging through the module and its multiple S+ children, but i'm not seeing anything that jumps out at me.?

I can't do RS422 because the camera is POE and no room for an additional cable in the pipe (long story).?

Any help would be appreciated.

Thanks,
Don




Join [email protected] to automatically receive all group messages.