OK, great, thanks.
It really looks easier.
toggle quoted message
Show quoted text
?
?take a look at the SB lighting modules
they do all you want (generates more code than you really
need, but all the functionality)
they work standalone w/o SB
?mark
---In
crestron@...,
wrote:
I have a residential
project: MC3, 12 x TPMC-4, 1x TMPC-9L, 4 x iPads
(Crestron Apps), 23 x Keypads.
I have 20 locations (rooms, staircases, pool, garage)
with 3-7 lightning circuits in each. Some of this
circuits are controlled by relays, some by dimmers, some
by DMX (RGB LEDS).
Some TP and KP will control "local" lights only but
TPMC-9 and iPad will control all.
How to design crosspoints system for that ??
I started by setting ecross for each lighting circuit
separate. Then I set ccross' es for each UI and routed
them to ecross.
So for example for first TP I have 5 ccross (statically
routed to 5 ecross by 5 eccon's) just to control lights.
Is that good way or maybe something easier??
Of course there will be AV and HVAC also to control.