Fluke DTX-1800 CableAnalyzer
per this document:
toggle quoted message
Show quoted text
--- In Crestron@..., Lincoln King-Cliby <lincoln@...> wrote:
Hi Fabio,
I don't know the model # off the top of my head & I'm on the road without it this week but I do know it's rather pricy (I want to say $10k-or-more-ish) so we only have one in the office; it's not quite "just throw it in your bag" material but it is very handy when you're commissioning a DM system or having "weird problems"
Lincoln
--
Lincoln King-Cliby, CTS
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Silver)
ControlWorks Consulting, LLC
Crestron Services Provider
-----Original Message-----
From: Crestron@... [mailto:Crestron@...] On Behalf Of fabiodaubermann
Sent: Thursday, June 20, 2013 11:28 AM
To: Crestron@...
Subject: [Crestron] Re: DMPS300 and RS232 on DM room boxes...
Hi Lincoln,
do you happen to know what model is the Fluke meter that Crestron recommends? Sounds like a must have tool in the bag...
I am suspecting that I might have some wiring and/or termination issues.
Thanks,
Fabio
--- In Crestron@..., Lincoln King-Cliby <lincoln@> wrote:
Check the IP table when the control doesn't seem to work -- specifically if the IP ID is "offline".
If the IPID is offline but you're passing video recheck and recertify (not just continuity test--use the Fluke meter that Crestron recommends) the DM cable. I've seen some "questionable" DM cables that pass video and DMNet (so you can use RCON .... commands) but not (good enough) Ethernet for the control side of the box to come online with the program.
Earlier this month I had a project where the box was dropping offline more frequently than I could count (literally)...the installers jiggled the DM cable and problem solved. (They did reterminate the suspect end, of course)
Lincoln
--
Lincoln King-Cliby, CTS
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Silver)
ControlWorks Consulting, LLC
Crestron Services Provider
-----Original Message-----
From: Crestron@... [mailto:Crestron@...] On Behalf Of fabiodaubermann
Sent: Wednesday, June 19, 2013 6:46 PM
To: Crestron@...
Subject: [Crestron] DMPS300 and RS232 on DM room boxes...
I am here on site with a DMPS-300 and I have a feeling that the RS232 on the DM-RMC-100-C's are flaky... sometimes it works, sometimes it doesn't... I can't put my finger in it yet, but it appears so...
I am controlling two Sharp TV's... very basic commands via SIO symbol (POWR0 \x0D , RSPW1 \x0D, POWR1 \x0D , etc...)
Anybody with similar experiences?
------------------------------------
Check out the Files area for useful modules, documents, and drivers.