Re: Reading Lutron Homeworks Illumination Output Strings


Heather Baiman
 

Download the legacy tools, Test Manager is in there. It is the "debugger" for x-series.
________________________________________
From: Crestron@... [Crestron@...] on behalf of sumocomputers [iwannagetmail@...]
Sent: Saturday, June 08, 2013 12:18 PM
To: Crestron@...
Subject: [Crestron] Reading Lutron Homeworks Illumination Output Strings

Having issues with Lutron to Crestron.
We are using a very old CNMSX-PRO with an equally old ST-COM connected
to a Lutron Homeworks Illumination Panel via RS-232, and having some
problems reading data from the Lutron correctly.
We know that when looking for strings coming out of Lutron, passing into
the ST-COM, we can correctly identify the string as an example, for the
Living Room Keypad Button in the following format, which matches up with
the Lutron documentation:
KBP, [01:06:07], 10\r
Just to clarify, we have logic on the ST-COM that says "when we see the
following string, go turn on the fireplace."
Here is an explanation of the string:
Keypad Button Press (KBP)Processor 1 (01)Link 6 (06)Keypad ID 7
(07)Button 10 (10)Carriage Return (\r)
The above works perfectly.
However, when we try other Keypads with other fireplaces, we get failure
to recognize the strings. After troubleshooting a little, it appears
that if the Keypad ID has double digits (like 10, 14, 16, etc), it
doesn't work. I suspect one of three things:
1. Although Lutron should be sending out ASCII, for some reason it is
sending out some other format (we cannot use SIMPL debugger to verify).
It should be noted that for a Keypad ID of 10 as an example, none of the
following worked placed into the ST-COM (note we are trying decimal,
ASCII, and hex). Also see screenshot down below.
KBP, [1:6:10], 5\r KBP, [01:06:10], 5\rKBP, [01:06:0A], 5\r
None of the above work at all.
2. The second possibility is that the Crestron is not correctly
translating the ASCII it is receiving, therefore not turning on the
fireplace.
3. Maybe we need to set some options on the ST-COM Module, that I am not
aware of. I tried to see if there is a way under "Configure Device" to
set it for ASCII, Hex, or Decimal, but there is no option like that.
What I really want to do, is monitor what the Crestron is really seeing
from the Lutron Panel when certain Lutron Keypad buttons are pressed,
but I think I need to use SIMPL Debugger for that. Since we cannot use
Toolbox, and therefore SIMPL Debugger with this CNMSX-PRO, we are stuck.
I tried using Toolbox and could not get it to work. Crestron verified
that Toolbox will not work with our CNMSX-PRO.
Please see Lutron documentation here:
;
rotocol%202.pdf
Please see screenshot of the ST-COM here:
;
t%206.15.31%20PM-1.jpg

Thanks


[Non-text portions of this message have been removed]



------------------------------------



Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the Database area.
Yahoo! Groups Links

Join [email protected] to automatically receive all group messages.